An Improved High-Sensitivity Airborne Transient Electromagnetic Sensor for Deep Penetration

The investigation depth of transient electromagnetic sensors can be effectively increased by reducing the system noise, which is mainly composed of sensor internal noise, electromagnetic interference (EMI), and environmental noise, etc. A high-sensitivity airborne transient electromagnetic (AEM) sensor with low sensor internal noise and good shielding effectiveness is of great importance for deep penetration. In this article, the design and optimization of such an AEM sensor is described in detail. To reduce sensor internal noise, a noise model with both a damping resistor and a preamplifier is established and analyzed. The results indicate that a sensor with a large diameter, low resonant frequency, and low sampling rate will have lower sensor internal noise. To improve the electromagnetic compatibility of the sensor, an electromagnetic shielding model for a central-tapped coil is established and discussed in detail. Previous studies have shown that unclosed shields with multiple layers and center grounding can effectively suppress EMI and eddy currents. According to these studies, an improved differential AEM sensor is constructed with a diameter, resultant effective area, resonant frequency, and normalized equivalent input noise of 1.1 m, 114 m2, 35.6 kHz, and 13.3 nV/m2, respectively. The accuracy of the noise model and the shielding effectiveness of the sensor have been verified experimentally. The results show a good agreement between calculated and measured results for the sensor internal noise. Additionally, over 20 dB shielding effectiveness is achieved in a complex electromagnetic environment. All of these results show a great improvement in sensor internal noise and shielding effectiveness.

[1]  G. Dehmel,et al.  Magnetic Field Sensors: Induction Coil (Search Coil) Sensors , 2008 .

[2]  Esben Auken,et al.  SkyTEM–a New High-resolution Helicopter Transient Electromagnetic System , 2004 .

[3]  B. Zadov,et al.  A Three-Axial Search Coil Magnetometer Optimized for Small Size, Low Power, and Low Frequencies , 2011, IEEE Sensors Journal.

[4]  Jun Zhu,et al.  Overhauser Geomagnetic Sensor Based on the Dynamic Nuclear Polarization Effect for Magnetic Prospecting , 2016, Sensors.

[5]  Chen Chen,et al.  An Optimized Air-Core Coil Sensor with a Magnetic Flux Compensation Structure Suitable to the Helicopter TEM System , 2016, Sensors.

[6]  Brian R. Spies,et al.  Depth of investigation in electromagnetic sounding methods , 1989 .

[7]  Douglas W. Oldenburg,et al.  Three-dimensional inversion of airborne time-domain electromagnetic data with applications to a porphyry deposit , 2012 .

[8]  J. Lenz,et al.  Magnetic sensors and their applications , 2006, IEEE Sensors Journal.

[9]  H. Séran,et al.  An optimized low-frequency three-axis search coil magnetometer for space research , 2005 .

[10]  Chen Chen,et al.  Investigation and Optimization of the Performance of an Air-Coil Sensor with a Differential Structure Suited to Helicopter TEM Exploration , 2015, Sensors.

[11]  Guangyou Fang,et al.  Equivalent Input Magnetic Noise Analysis for the Induction Magnetometer of 0.1 mHz to 1 Hz , 2014, IEEE Sensors Journal.

[12]  Andrea Viezzoli,et al.  High-Resolution Near Surface Airborne Electromagnetics – SkyTEM Survey for Uranium Exploration at Pells Range, WA , 2007 .

[13]  Mark E. Everett,et al.  Near-Surface Applied Geophysics , 2013 .

[14]  Jun Lin,et al.  High-sensitivity cooled coil system for nuclear magnetic resonance in kHz range. , 2014, The Review of scientific instruments.

[15]  Richard S. Smith,et al.  64 Advances in Airborne Time-Domain EM Technology , 1997 .

[16]  S. Tumański Induction coil sensors—a review , 2007 .