Microparticle image velocimetry approach to flow measurements in isolated contracting lymphatic vessels

Abstract. We describe the development of an optical flow visualization method for resolving the flow velocity vector field in lymphatic vessels in vitro. The aim is to develop an experimental protocol for accurately estimating flow parameters, such as flow rate and shear stresses, with high spatial and temporal resolution. Previous studies in situ have relied on lymphocytes as tracers, but their low density resulted in a reduced spatial resolution whereas the assumption that the flow was fully developed in order to determine the flow parameters of interest may not be valid, especially in the vicinity of the valves, where the flow is undoubtedly more complex. To overcome these issues, we have applied the time-resolved microparticle image velocimetry (μ-PIV) technique, a well-established method that can provide increased spatial and temporal resolution that this transient flow demands. To that end, we have developed a custom light source, utilizing high-power light-emitting diodes, and associated control and image processing software. This paper reports the performance of the system and the results of a series of preliminary experiments performed on vessels isolated from rat mesenteries, demonstrating, for the first time, the successful application of the μ-PIV technique in these vessels.

[1]  Gerard L Coté,et al.  Measuring microlymphatic flow using fast video microscopy. , 2005, Journal of biomedical optics.

[2]  Sunkuk Kwon,et al.  Noninvasive quantitative imaging of lymph function in mice. , 2007, Lymphatic research and biology.

[3]  A. Naqwi,et al.  Video systems for PIV recording , 1998 .

[4]  A. Galbis,et al.  Vector Analysis Versus Vector Calculus , 2012 .

[5]  Damien Garcia,et al.  A fast all-in-one method for automated post-processing of PIV data , 2011, Experiments in fluids.

[6]  Ronald J. Adrian,et al.  Dynamic ranges of velocity and spatial resolution of particle image velocimetry , 1997 .

[7]  H. Florey Observations on the contractility of lacteals , 1927 .

[8]  William Thielicke,et al.  PIVlab – Towards User-friendly, Affordable and Accurate Digital Particle Image Velocimetry in MATLAB , 2014 .

[9]  R K Jain,et al.  Transport in lymphatic capillaries. I. Macroscopic measurements using residence time distribution theory. , 1996, The American journal of physiology.

[10]  Gerard L. Coté,et al.  Image Correlation Algorithm for Measuring Lymphocyte Velocity and Diameter Changes in Contracting Microlymphatics , 2007, Annals of Biomedical Engineering.

[11]  J. Mcgeown,et al.  Peripheral lymphatic responses to outflow pressure in anaesthetized sheep. , 1987, The Journal of physiology.

[12]  Christian Willert,et al.  Pulsed operation of high-power light emitting diodes for imaging flow velocimetry , 2010 .

[13]  D. Zawieja,et al.  Determining the combined effect of the lymphatic valve leaflets and sinus on resistance to forward flow. , 2015, Journal of biomechanics.

[14]  S. Y. Lee,et al.  Digital Filters for Reducing Background Noise in Micro PIV Measurements , 2002 .

[15]  Christian J. Kähler,et al.  On the effect of particle image intensity and image preprocessing on the depth of correlation in micro-PIV , 2012 .

[16]  Wilhelm Burger,et al.  Principles of Digital Image Processing - Fundamental Techniques , 2010, Undergraduate Topics in Computer Science.

[17]  Ruikang K. Wang,et al.  Label-Free Optical Imaging of Lymphatic Vessels Within Tissue Beds IN VIVO , 2014, IEEE Journal of Selected Topics in Quantum Electronics.

[18]  G. Nicolaysen,et al.  Lymph Flow Pattern in the Intact Thoracic Duct in Sheep , 1997, The Journal of physiology.

[19]  D. Zawieja,et al.  Regional Variations of Contractile Activity in Isolated Rat Lymphatics , 2004, Microcirculation.

[20]  D. Zawieja,et al.  Confocal image-based computational modeling of nitric oxide transport in a rat mesenteric lymphatic vessel. , 2013, Journal of biomechanical engineering.

[21]  David Zawieja,et al.  Molecular and functional analyses of the contractile apparatus in lymphatic muscle , 2003, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[22]  R K Jain,et al.  Transport in lymphatic capillaries. II. Microscopic velocity measurement with fluorescence photobleaching. , 1996, The American journal of physiology.

[23]  L. Lourenço Particle Image Velocimetry , 1989 .

[24]  Carl D. Meinhart,et al.  Recent Advances in Micro-Particle Image Velocimetry , 2010 .

[25]  E. Galanzha,et al.  LASER BIOLOGY AND MEDICINE: Recording of lymph flow dynamics in microvessels using correlation properties of scattered coherent radiation , 2002 .

[26]  Richard Cole,et al.  Live-cell imaging , 2014, Cell adhesion & migration.

[27]  James Brandon Dixon,et al.  A biomedical engineering approach to investigating flow and wall shear stress in contracting lymphatics , 2006 .

[28]  Label-free 3D imaging of microstructure, blood, and lymphatic vessels within tissue beds in vivo. , 2012, Optics letters.

[29]  Valery V Tuchin,et al.  Advances in small animal mesentery models for in vivo flow cytometry, dynamic microscopy, and drug screening. , 2007, World journal of gastroenterology.

[30]  Markus Raffel,et al.  Particle Image Velocimetry: A Practical Guide , 2002 .

[31]  Kang Ryoung Park,et al.  Finger vein recognition using minutia‐based alignment and local binary pattern‐based feature extraction , 2009, Int. J. Imaging Syst. Technol..

[32]  Matthias Wessling,et al.  On image pre-processing for PIV of single- and two-phase flows over reflecting objects , 2010 .

[33]  D. Zawieja,et al.  Nitric oxide formation by lymphatic bulb and valves is a major regulatory component of lymphatic pumping. , 2011, American journal of physiology. Heart and circulatory physiology.

[34]  Shi Ke,et al.  Quantitative imaging of lymph function. , 2007, American journal of physiology. Heart and circulatory physiology.

[35]  C. Cierpka,et al.  Particle imaging techniques for volumetric three-component (3D3C) velocity measurements in microfluidics , 2011, Journal of Visualization.

[36]  Damien Garcia,et al.  Robust smoothing of gridded data in one and higher dimensions with missing values , 2010, Comput. Stat. Data Anal..

[37]  Marek Belohlavek,et al.  Flow Velocity Vector Fields by Ultrasound Particle Imaging Velocimetry , 2011, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[38]  R. Black,et al.  Modelling the lymphatic system: challenges and opportunities , 2012, Journal of The Royal Society Interface.

[39]  Andreas Fouras,et al.  Improvement of measurement accuracy in micro PIV by image overlapping , 2010 .

[40]  H. Florey Observations on the contractility of lacteals: Part I. , 2022, The Journal of physiology.

[41]  John T. Wen,et al.  Adaptive scanning optical microscope: large field of view and high-resolution imaging using a MEMS deformable mirror , 2008 .

[42]  Gerard L Cote,et al.  Lymph Flow, Shear Stress, and Lymphocyte Velocity in Rat Mesenteric Prenodal Lymphatics , 2006, Microcirculation.

[43]  Vyacheslav Kalchenko,et al.  Label free in vivo laser speckle imaging of blood and lymph vessels. , 2012, Journal of biomedical optics.

[44]  A. Bollinger,et al.  Flow velocity of single lymphatic capillaries in human skin. , 1996, The American journal of physiology.

[45]  Timothy Kassis,et al.  Dual-channel in-situ optical imaging system for quantifying lipid uptake and lymphatic pump function. , 2012, Journal of biomedical optics.

[46]  M. Swartz,et al.  The physiology of the lymphatic system. , 2001, Advanced drug delivery reviews.

[47]  R. Webb,et al.  Confocal microscope with large field and working distance. , 1999, Applied optics.

[48]  R E Poelmann,et al.  Measurements of the wall shear stress distribution in the outflow tract of an embryonic chicken heart , 2010, Journal of The Royal Society Interface.

[49]  Valery V Tuchin,et al.  In vivo multispectral, multiparameter, photoacoustic lymph flow cytometry with natural cell focusing, label‐free detection and multicolor nanoparticle probes , 2008, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[50]  J. Zwischenberger,et al.  New method for evaluation of lung lymph flow rate with intact lymphatics in anaesthetized sheep , 2007, Acta physiologica.

[51]  Jerry Westerweel,et al.  Micro-Particle Image Velocimetry (microPIV): recent developments, applications, and guidelines. , 2009, Lab on a chip.

[52]  Holger Nobach,et al.  Background extraction from double-frame PIV images , 2005 .

[53]  R. Adrian,et al.  Out-of-focus effects on particle image visibility and correlation in microscopic particle image velocimetry , 2000 .