Energy effects of heat-island reduction strategies in Toronto, Canada

The effect of heat-island reduction (HIR) strategies on annual energy savings and peak-power avoidance of the building sector of the Greater Toronto Area is calculated, using an hourly building energy simulation model. Results show that ratepayers could realize potential annual energy savings of over $11M from the effects of HIR strategies. The residential sector accounts for over half (59%) of the total savings, offices 13% and retail stores 28%. Savings from cool roofs are about 20%, shade trees 30%, wind shielding of trees 37%, and ambient cooling by trees and reflective surfaces 12%. These results are preliminary and highly sensitive to the relative price of gas and electricity. Potential annual electrticity savings are estimated at about 150 GWh and potential peak power avoidance at 250 MW.

[1]  S. Konopacki,et al.  Demonstration of Energy Savings of Cool Roofs , 1998 .

[2]  Max H. Sherman,et al.  Variability in Residential Air Leakage , 1986 .

[3]  S. Konopacki Simulated Impact of Roof Surface Solar Absorptance, Attic, and Duct Insulation, and Duct Insulation on Cooling and Heating Energy Use in Single-Family Residential Buildings , 1998 .

[4]  H. Akbari,et al.  Cool surfaces and shade trees to reduce energy use and improve air quality in urban areas , 2001 .

[5]  L. Gu,et al.  Measured and simulated performance of reflective roofing systems in residential buildings , 1998 .

[6]  S. Konopacki,et al.  Cooling energy savings potential of light-colored roofs for residential and commercial buildings in 11 US metropolitan areas , 1997 .

[7]  Danny S. Parker,et al.  Improving DOE-2's RESYS routine: User defined functions to provide more accurate part load energy use and humidity predictions , 2000 .

[8]  R. Moore,et al.  Assessing the impacts of white roofs on building energy loads , 1998 .

[9]  Hashem Akbari,et al.  Energy impacts of heat island reduction strategies in the Greater Toronto Area, Canada , 2001 .

[10]  G. Grell,et al.  A description of the fifth-generation Penn State/NCAR Mesoscale Model (MM5) , 1994 .

[11]  Hashem Akbari,et al.  Peak power and cooling energy savings of high-albedo roofs , 1997 .

[12]  F. C. Winkelmann,et al.  Overview of the DOE-2 Building Energy Analysis Program , 1985 .

[13]  Danny S. Parker,et al.  Demonstration of Cooling Savings of Light Colored Roof Surfacing in Florida Commercial Buildings: Retail Strip Mall , 2002 .

[14]  H. Akbari,et al.  Energy savings for heat-island reduction strategies in Chicago and Houston (including updates for Baton Rouge, Sacramento, and Salt Lake City) , 2002 .

[15]  Danny S. Parker,et al.  Measured performance of a reflective roofing system in a Florida commercial building , 1998 .

[16]  H. Akbari,et al.  Simulated Impact of Roof Solar Absorptance, Attic, and DuctInsulation, and Climate on Cooling and Heating Energy Use inSingle-Family Resi dential Buildings , 1998 .

[17]  H. Akbari,et al.  The impact of trees and white surfaces on residential heating and cooling energy use in four Canadian cities , 1992 .

[18]  H. Akbari,et al.  Calculations for reflective roofs in support of Standard 90.1 , 1998 .

[19]  H. Akbari,et al.  Energy Savings Calculations for Heat Island Reduction Strategies in Baton Rouge, Sacramento and Salt Lake City , 2000 .

[20]  Leo Rainer,et al.  Measured Energy Savings from the Application of Reflective Roofs in 3 AT and T Regeneration Buildings , 2000 .

[21]  J. J. Hirsch,et al.  DOE-2 supplement: Version 2.1E , 1993 .

[22]  Hashem Akbari,et al.  Peak power and cooling energy savings of shade trees , 1997 .

[23]  H. Akbari,et al.  Long-term performance of high-albedo roof coatings , 1997 .

[24]  Hashem Akbari,et al.  Measured energy savings and demand reduction from a reflective roof membrane on a large retail store in Austin , 2001 .