Can Paper Replace Laser Film to Communicate the Results of Wrist Radiographs in Trauma Cases? A Reproducibility Study of the Reading of Wrist Trauma Case Radiographs on a PACS Workstation, Laser Film, and Paper

The main goal of this study was to determine the reproducibility of the reading of wrist trauma case radiographs using three different media: laser film, a picture archiving and communication systems (PACS) workstation, and paper with an optimized layout. The study was conducted retrospectively in 200 consecutive patients consulting at the emergency department for wrist trauma and who underwent wrist X-ray investigation using a computed radiography system. There were 82 men and 118 women. The mean age was 48.3 years (16–95 years). Our institutional review board does not require patient approval or informed consent for retrospective review of case records. The readings were made by two independent readers who analyzed the 200 patient radiographs consecutively in one session for each type of media: paper, laser film, and on a PACS dual-screen workstation. The inter-reader agreements were substantial or almost perfect, with kappa values of 0.83 (0.76–0.90) for the PACS, 0.83 (0.76–0.90) for film, and 0.80 (0.72–0.87) for paper. The inter-technique agreement was almost perfect in all cases. There is a high interobserver agreement between PACS, laser film, and paper readings for wrist trauma cases. With a layout of one radiograph on each sheet, paper could replace laser films to communicate the results of wrist radiographs in trauma cases for outpatients.

[1]  W H McAlister,et al.  Skeletal surveys for child abuse: comparison of interpretation using digitized images and screen-film radiographs. , 1998, AJR. American journal of roentgenology.

[2]  T. Helbich,et al.  Image quality of a wet laser printer versus a paper printer for full-field digital mammograms. , 2006, AJR. American journal of roentgenology.

[3]  E L Siegel,et al.  Effect of filmless imaging on the utilization of radiologic services. , 2000, Radiology.

[4]  S. Lecocq,et al.  Evaluation of the diagnostic performance of tomosynthesis in fractures of the wrist. , 2012, AJR. American journal of roentgenology.

[5]  NeedsFixing Need for image, data portability opens door for electronic answers , 2010 .

[6]  Anthony J Doyle,et al.  Personal computer versus workstation display: observer performance in detection of wrist fractures on digital radiographs. , 2005, Radiology.

[7]  Stewart Denslow Desktop publishing and medical imaging: Paper as hardcopy medium for digital images , 2009, Journal of Digital Imaging.

[8]  E. Kotter,et al.  Using receiver operating characteristic methodology to evaluate the diagnostic quality of radiography on paper prints versus film. , 2003, AJR. American journal of roentgenology.

[9]  Olof Jarlman,et al.  Evaluation of the image quality of ink-jet printed paper copies of digital chest radiographs as compared with film: A receiver operating characteristic study , 1994, Journal of Digital Imaging.

[10]  G S Ibbott,et al.  Reproduction of radiologic images on plain paper. , 1998, Radiographics : a review publication of the Radiological Society of North America, Inc.

[11]  K S Berbaum,et al.  Analysis of the cost-effectiveness of PACS. , 1991, AJR. American journal of roentgenology.

[12]  W. Khaliq,et al.  Comparison of a PACS Workstation with Laser Hard Copies for Detecting Scaphoid Fractures in the Emergency Department , 2010, Journal of Digital Imaging.

[13]  Chris Roberts,et al.  Modelling patterns of agreement for nominal scales , 2008, Statistics in medicine.

[14]  C. Pfirrmann,et al.  MRI of meniscal lesions: soft-copy (PACS) and hard-copy evaluation versus reviewer experience. , 2006, AJR. American journal of roentgenology.

[15]  H. Kundel,et al.  Reliability of soft-copy versus hard-copy interpretation of emergency department radiographs: a prototype study. , 2001, AJR. American journal of roentgenology.

[16]  A. Blum,et al.  Le diagnostic des fractures rcentes du scaphode : revue de la littrature , 2007 .

[17]  A. Blum,et al.  [The diagnosis of recent scaphoid fractures: review of the literature]. , 2007, Journal de radiologie.

[18]  Zhigang Liang,et al.  Comparison of dry laser printer versus paper printer in full-field digital mammography , 2010, Acta radiologica.

[19]  C. Hasler,et al.  Digital imaging data on CD-R: a time trap for orthopaedic surgeons in outpatient clinics , 2009, Journal of children's orthopaedics.

[20]  G Weatherburn,et al.  The effect of a Picture Archiving and Communications System (PACS) on diagnostic performance in the accident and emergency department , 2000, Journal of accident & emergency medicine.

[21]  J. Borm,et al.  The Value of Radiographs and Bone Scintigraphy in Suspected Scaphoid Fracture , 1993, Journal of Hand Surgery-American Volume.

[22]  Eliot L Siegel,et al.  Accuracy of interpretation of CT scans: comparing PACS monitor displays and hard-copy images. , 2002, AJR. American journal of roentgenology.

[23]  D. Robinson,et al.  Role of MRI in the diagnosis of clinically suspected scaphoid fracture: analysis of 611 consecutive cases and literature review , 2010, Emergency Medicine Journal.