A MICS telemetry implant powered by a 27MHz ISM inductive link

An implantable telemetry device is presented, inductively powered by a 5.8mW 27MHz ISM-band supply and received with a stacked-spiral implantable power coil. A 15th harmonic 405MHz MICS-band data carrier is generated from the power signal, data-modulated, filtered and sent to a receiver via a wireless data link. The implantable module is tested in a biological environment, successfully proving the concept.

[1]  Moo Sung Chae,et al.  A Wideband Telemetry Unit for Multi-Channel Neural Recording Systems , 2007, 2007 IEEE International Conference on Ultra-Wideband.

[2]  Mehmet R. Yuce,et al.  Integrated VCO Design for MICS Transceivers , 2006, IEEE Custom Integrated Circuits Conference 2006.

[3]  Mohammad Ghavami,et al.  Miniaturized implantable broadband antenna for biotelemetry communication , 2008 .

[4]  P.R. Troyk,et al.  Closed-loop class E transcutaneous power and data link for MicroImplants , 1992, IEEE Transactions on Biomedical Engineering.

[5]  Ching-Hsing Luo,et al.  Compact broadband stacked implantable antenna for biotelemetry with medical devices , 2006, 2006 IEEE Annual Wireless and Microwave Technology Conference.

[6]  M. Yuce,et al.  Stacked Spirals for Biosensor Telemetry , 2011, IEEE Sensors Journal.

[7]  Zhi Yang,et al.  Inductor Modeling in Wireless Links for Implantable Electronics , 2007, IEEE Transactions on Magnetics.

[8]  No Sokal,et al.  CLASS-E - NEW CLASS OF HIGH-EFFICIENCY TUNED SINGLE-ENDED SWITCHING POWER AMPLIFIERS , 1975 .

[9]  P. Vaillancourt,et al.  EM radiation behavior upon biological tissues in a radio-frequency power transfer link for a cortical visual implant , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[10]  Mehmet R. Yuce,et al.  Harmonics-based bio-implantable telemetry system , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  Mehmet R. Yuce,et al.  Class-E oscillators as wireless power transmitters for biomedical implants , 2010, 2010 3rd International Symposium on Applied Sciences in Biomedical and Communication Technologies (ISABEL 2010).

[12]  Ieee Standards Board IEEE standard for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3kHz to 300 GHz , 1992 .

[13]  S. Paek,et al.  Air-gap stacked spiral inductor , 1997 .