Performance evaluation of building integrated solar thermal shading system: Building energy consumption and daylight provision

Abstract This paper evaluated the performance of the building integrated solar thermal shading (BISTS) system on building energy consumption and daylight levels through energy and daylighting modeling and simulations. A medium office reference building in Los Angeles defined by the DOE was used in the case studies. The horizontal BISTS louvers on the south windows and vertical BISTS louvers on the east and west windows were modeled and simulated. The final BISTS configuration was achieved by considering the balance between primary energy savings and daylight provision. The results revealed that 1) the BISTS system could effectively improve the daylight condition for a single perimeter room by increasing the useful daylight level and reducing the excessive level. 2) The savings for the building energy consumption were not significant. The final design with the BISTS layouts on three facades could result in 5.3% of total primary energy saving. 3) 90° of slat angle should be avoided for both the horizontal and vertical BISTS louvers. Smaller angles – between 0° and 60° – are preferred.

[1]  Jim Euchner Design , 2014, Catalysis from A to Z.

[2]  Yvan J. Beliveau,et al.  Design, construction and performance prediction of integrated solar roof collectors using finite element analysis , 2007 .

[3]  Ming Qu,et al.  Performance evaluation of building integrated solar thermal shading system: Active solar energy usage , 2017 .

[4]  Theocharis Tsoutsos,et al.  Integrated PV in shading systems for Mediterranean countries: Balance between energy production and visual comfort , 2014 .

[5]  Athanasios Tzempelikos,et al.  Daylighting and energy analysis of private offices with automated interior roller shades , 2012 .

[6]  Athanasios Tzempelikos,et al.  Comparative control strategies for roller shades with respect to daylighting and energy performance , 2013 .

[7]  Christoph F. Reinhart,et al.  Validation of dynamic RADIANCE-based daylight simulations for a test office with external blinds , 2001 .

[8]  Athanasios Tzempelikos,et al.  Efficient venetian blind control strategies considering daylight utilization and glare protection , 2013 .

[9]  Gilles Notton,et al.  A building integrated solar collector: Performances characterization and first stage of numerical calculation , 2013 .

[10]  Athanasios Tzempelikos,et al.  A hybrid ray-tracing and radiosity method for calculating radiation transport and illuminance distribution in spaces with venetian blinds , 2012 .

[11]  Jeff Haberl,et al.  Historical Survey of Daylighting Calculations Methods and Their Use in Energy Performance Simulations , 2009 .

[12]  Christoph Maurer,et al.  Heating and cooling in high-rise buildings using facade-integrated transparent solar thermal collector systems , 2013 .

[13]  Sona Raeissi,et al.  Optimum overhang dimensions for energy saving , 1998 .

[14]  A. B. Sawant,et al.  Light Transmitting Concrete by using Optical Fiber , 2014 .

[15]  Armando C. Oliveira,et al.  Effect of louver shading devices on building energy requirements , 2010 .

[16]  John Mardaljevic,et al.  Useful daylight illuminances: A replacement for daylight factors , 2006 .

[17]  Jayanta Deb Mondol,et al.  Modelling and simulation of Building-Integrated solar thermal systems: Behaviour of the system , 2015 .

[18]  Zhenqing Wang,et al.  Performance and building integration of all-ceramic solar collectors , 2014 .

[19]  Gilles Notton,et al.  Life cycle analysis of a building-integrated solar thermal collector, based on embodied energy and embodied carbon methodologies , 2014 .

[20]  Theocharis Tsoutsos,et al.  Assessment of fixed shading devices with integrated PV for efficient energy use , 2012 .

[21]  Armando C. Oliveira,et al.  Evaluation of a solar thermal system using building louvre shading devices , 2006 .

[22]  Bing Liu,et al.  Analysis of Daylighting Requirements within ASHRAE Standard 90.1 , 2013 .

[23]  Gilles Notton,et al.  The environmental performance of a building-integrated solar thermal collector, based on multiple approaches and life-cycle impact assessment methodologies. , 2015 .

[24]  S. Citherleta,et al.  Integration in building physics simulation , 2001 .

[25]  Tomas Matuska,et al.  Façade solar collectors , 2006 .

[26]  John Mardaljevic,et al.  Useful daylight illuminance: a new paradigm for assessing daylight in buildings , 2005 .

[27]  Jayanta Deb Mondol,et al.  Modelling and simulation of Building-Integrated solar thermal systems: Behaviour of the coupled building/system configuration , 2015 .

[28]  Marco Manzan,et al.  Genetic optimization of external fixed shading devices , 2014 .