The Groin Vaults of St. John Hospital in Jerusalem: An Experimental Analysis on a Scale Model

ABSTRACT The St. John Hospital is part of a larger complex of buildings known as the Hospitallers Quarter, located south of the Holy Sepulchre in Jerusalem. At present, the hospital looks like an irregular volume both in height and in plan; it is covered by ten groin vaults resting on very stocky pillars. Each vault is formed by intersecting double curvature surfaces. In order to verify the effectiveness of continuous carbon fiber reinforced polymer sheets reinforcement, bonded at the extrados of vaults, laboratory tests were carried out on a 1:5 scale model, built with materials and construction techniques similar to those of the real building. Experimental tests were performed on the unstrengthened and strengthened vault. The experimental results shown that the strengthening system is able to increase the collapse load of the vault, without substantial variation of the initial stiffness.

[1]  R. Al-Mahaidi,et al.  Experimental investigation on the thermal and mechanical properties of nanoclay-modified adhesives used for bonding CFRP to concrete substrates , 2012 .

[2]  Luisa Rovero,et al.  Experimental Study of Bond Behavior of CFRP-to-Brick Joints , 2015 .

[3]  S F Broomhead,et al.  STRENGTHENING MASONRY ARCHES , 1995 .

[4]  Antonio Borri,et al.  Theoretical Analysis and a case study of historical masonry vault strengthened by using advanced FRP , 2000 .

[5]  Luisa Rovero,et al.  Towards a methodology for estimating strength and collapse mechanism in masonry arches strengthened with fibre reinforced polymer applied on external surfaces , 2008 .

[6]  Silvia Briccoli Bati,et al.  Lower Bound Limit Analysis of Masonry Arches with CFRP Reinforcements: A Numerical Method , 2013 .

[7]  Paolo Foraboschi,et al.  Strengthening of Masonry Arches with Fiber-Reinforced Polymer Strips , 2004 .

[8]  Antonio Borri,et al.  Intrados strengthening of brick masonry arches with composite materials , 2011 .

[9]  Laura Anania,et al.  The post strengthening of the masonry vaults by the Ω-Wrap technique based on the use of C-FRP , 2013 .

[10]  T. Triantafillou Strengthening of Masonry Structures Using Epoxy-Bonded FRP Laminates , 1998 .

[11]  Angelo D'Ambrisi,et al.  Masonry arches strengthened with composite unbonded tendons , 2013 .

[12]  N. Zani,et al.  Dynamic Analysis of FRP-Reinforced Masonry Arches via a No-Tension Model with Damage , 2014 .

[13]  Giovanni Carbonara,et al.  Trattato di restauro architettonico , 1996 .

[14]  P. Lourenço,et al.  Experimental Behavior of FRP Strengthened Masonry Arches , 2010 .

[15]  Asif Usmani,et al.  Assessment of the Structural Response of Masonry Cross Vaults , 2002 .

[16]  Asif Usmani,et al.  Case study of the failure of a cross vault: Church of Holyrood abbey , 2003 .

[17]  C. Modena,et al.  Behavior of Brick Masonry Vaults Strengthened by FRP Laminates , 2001 .

[18]  Maura Imbimbo,et al.  Experimental tests and numerical modeling of reinforced masonry arches , 2010 .