Finite element and experimental models of cemented hip joint reconstructions can produce similar bone and cement strains in pre-clinical tests.

Finite element (FE) models could be used for pre-clinical testing of cemented hip replacement implants against the damage accumulation failure scenario. To accurately predict mechanical failure, the models should accurately predict stresses and strains. This should be the case for various implants. In the current study, two FE models of composite hip reconstructions with two different implants were validated relative to experimental bone and cement strains. The objective was an overall agreement within 10% between experimental and FE strains. Two stem types with different clinical results were analyzed: the Lubinus SPII and the Mueller Curved with loosening rates of 4% and 16% after 10 yr, respectively (Prognosis of total hip replacement. 63rd Annual Meeting of the American Academy of orthopaedic surgeons, Atlanta, USA). For both implant types, six stems were implanted in composite femurs. All specimens were subjected to bending. The Mueller Curved specimens were additionally subjected to torsion. Bone strains were recorded at 10 locations on the cortex and cement strains at three locations within the cement mantle. An FE model was built for both stem types and the experiments were simulated. Bone and cement strains were calculated at the experimental gauge locations. Most FE bone strains corresponded to the mean experimental strains within two standard deviations; most FE cement strains within one standard deviation. Linear regression between the FE and mean experimental strains produced slopes between 0.82 and 1.03, and R(2) values above 0.98. Particularly for the Mueller Curved, agreement improved considerably when FE strains were compared to the strains from the experimental specimen used to build the FE model. The objective of overall agreement within 10% was achieved, indicating that both FE models were successfully validated. This prerequisite for accurately predicting long-term failure has been satisfied.

[1]  W. Harris,et al.  Factors affecting cement strains near the tip of a cemented femoral component. , 1997, The Journal of arthroplasty.

[2]  Nico Verdonschot,et al.  Sensitivity of failure criteria of cemented total hip replacements to finite element mesh density , 1998 .

[3]  A. Cappello,et al.  Mechanical validation of whole bone composite tibia models. , 2000, Journal of biomechanics.

[4]  W J Maloney,et al.  The initiation of failure in cemented femoral components of hip arthroplasties. , 1991, The Journal of bone and joint surgery. British volume.

[5]  L Cristofolini,et al.  A critical analysis of stress shielding evaluation of hip prostheses. , 1997, Critical reviews in biomedical engineering.

[6]  R. Robinson,et al.  Early femoral component loosening in DF-80 total hip arthroplasty. , 1989, The Journal of arthroplasty.

[7]  Max Schaldach,et al.  Engineering in Medicine , 1975 .

[8]  Rita M. Patterson,et al.  Femoral surface strain in intact composite femurs: a custom computer analysis of the photoelastic coating technique , 2000, IEEE Transactions on Biomedical Engineering.

[9]  M Viceconti,et al.  TRI2SOLID: an application of reverse engineering methods to the creation of CAD models of bone segments. , 1998, Computer methods and programs in biomedicine.

[10]  M Viceconti,et al.  A comparative study on different methods of automatic mesh generation of human femurs. Medical Engineering and Physics 20 (1998): 1-10. , 2000, Medical engineering & physics.

[11]  T P Harrigan,et al.  A finite element study of the initiation of failure of fixation in cemented femoral total hip components , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[12]  M Semlitsch,et al.  Ten years of experience with test criteria for fracture-proof anchorage stems of artificial hip joints. , 1983, Engineering in medicine.

[13]  R. Huiskes,et al.  Failed innovation in total hip replacement. Diagnosis and proposals for a cure. , 1993, Acta orthopaedica Scandinavica.

[14]  Hwj Rik Huiskes,et al.  Strains in composite hip joint reconstructions obtained through FEA and experiments correspond closely , 2000 .

[15]  W. F. Riley,et al.  Experimental stress analysis , 1978 .

[16]  N Verdonschot,et al.  The effects of cement-stem debonding in THA on the long-term failure probability of cement. , 1997, Journal of biomechanics.

[17]  L Cristofolini,et al.  A comparative study on different methods of automatic mesh generation of human femurs. , 1998, Medical engineering & physics.

[18]  P Herberts,et al.  Prognosis of total hip replacement: A Swedish multicenter study of 4,664 revisions , 1990 .

[19]  L. Whiteside,et al.  Effects of femoral component material properties on cementless fixation in total hip arthroplasty. A comparison study between carbon composite, titanium alloy, and stainless steel. , 1993, The Journal of arthroplasty.

[20]  A Rohlmann,et al.  Is staircase walking a risk for the fixation of hip implants? , 1995, Journal of biomechanics.

[21]  L Cristofolini,et al.  Mechanical validation of whole bone composite femur models. , 1996, Journal of biomechanics.

[22]  A Rohlmann,et al.  Finite-element-analysis and experimental investigation in a femur with hip endoprosthesis. , 1983, Journal of biomechanics.

[23]  Marco Viceconti,et al.  Development and validation of a technique for strain measurement inside polymethyl methacrylate , 2000 .

[24]  J H Keyak,et al.  Validation of an automated method of three-dimensional finite element modelling of bone. , 1993, Journal of biomedical engineering.

[25]  Ad F. M. Diepstraten,et al.  The Netherlands Orthopedic Society: Nijmegen, January 12-14, 1989 , 1990 .

[26]  B P McNamara,et al.  Relationship between bone-prosthesis bonding and load transfer in total hip reconstruction. , 1997, Journal of biomechanics.

[27]  W. Hayes,et al.  Cross-sectional geometry of Pecos Pueblo femora and tibiae--a biomechanical investigation: I. Method and general patterns of variation. , 1983, American journal of physical anthropology.