Laser diode absorption spectroscopy for accurate CO(2) line parameters at 2 microm: consequences for space-based DIAL measurements and potential biases.

Space-based active sensing of CO(2) concentration is a very promising technique for the derivation of CO(2) surface fluxes. There is a need for accurate spectroscopic parameters to enable accurate space-based measurements to address global climatic issues. New spectroscopic measurements using laser diode absorption spectroscopy are presented for the preselected R30 CO(2) absorption line ((20(0)1)(III)<--(000) band) and four others. The line strength, air-broadening halfwidth, and its temperature dependence have been investigated. The results exhibit significant improvement for the R30 CO(2) absorption line: 0.4% on the line strength, 0.15% on the air-broadening coefficient, and 0.45% on its temperature dependence. Analysis of potential biases of space-based DIAL CO(2) mixing ratio measurements associated to spectroscopic parameter uncertainties are presented.

[1]  Jirong Yu,et al.  Side-line tunable laser transmitter for differential absorption lidar measurements of CO2: design and application to atmospheric measurements. , 2008, Applied optics.

[2]  David Crisp,et al.  Precision requirements for space-based XCO2 data , 2007 .

[3]  E. Turiel The Development of Morality , 2007 .

[4]  V. Malathy Devi,et al.  Line strengths of 12C16O2: 4550–7000 cm−1 , 2006 .

[5]  V. Malathy Devi,et al.  Spectroscopic database of CO2 line parameters: 4300–7000 cm−1 , 2008 .

[6]  A. Vicet,et al.  In situ sensing of atmospheric CO2 with laser diodes near 2.05 μm: a spectroscopic study , 2004 .

[7]  M. Wirth,et al.  Development of an OPO system at 1.57 μm for integrated path DIAL measurement of atmospheric carbon dioxide , 2008 .

[8]  P. Rayner,et al.  The utility of remotely sensed CO2 concentration data in surface source inversions , 2001 .

[9]  Gang Li,et al.  The HITRAN 2008 molecular spectroscopic database , 2005 .

[10]  B. Parvitte,et al.  Development of a compact CO2 sensor open to the atmosphere and based on near-infrared laser technology at 2.68 μm , 2007 .

[11]  P. Flamant,et al.  Two-micrometer heterodyne differential absorption lidar measurements of the atmospheric CO2 mixing ratio in the boundary layer. , 2006, Applied optics.

[12]  D. Tratt,et al.  Differential laser absorption spectrometry for global profiling of tropospheric carbon dioxide: selection of optimum sounding frequencies for high-precision measurements. , 2003, Applied optics.

[13]  S. Houweling,et al.  Space-borne remote sensing of CO2, CH4, and N2O by integrated path differential absorption lidar: a sensitivity analysis , 2008 .

[14]  F. Gibert,et al.  A complete study of CO2 line parameters around 4845 cm−1 for Lidar applications , 2008 .

[15]  Jacques Pelon,et al.  Complementary study of differential absorption lidar optimization in direct and heterodyne detections. , 2006, Applied optics.

[16]  V. Malathy Devi,et al.  Air-broadened halfwidth and pressure shift coefficients of 12C16O2 bands: 4750–7000 cm−1 , 2007 .

[17]  Jeffrey Y. Beyon,et al.  Coherent differential absorption lidar measurements of CO2. , 2004, Applied optics.

[18]  Daisuke Sakaizawa,et al.  Development of a 1.6 microm differential absorption lidar with a quasi-phase-matching optical parametric oscillator and photon-counting detector for the vertical CO2 profile. , 2009, Applied optics.

[19]  M. Reichstein,et al.  Net regional ecosystem CO2 exchange from airborne and ground‐based eddy covariance, land‐use maps and weather observations , 2007 .

[20]  J. Cuesta,et al.  Vertical 2-μm Heterodyne Differential Absorption Lidar Measurements of Mean CO2 Mixing Ratio in the Troposphere , 2008 .

[21]  U. Singh,et al.  1 J/pulse Q-switched 2 microm solid-state laser. , 2006, Optics letters.

[22]  Bertrand Parvitte,et al.  A complete study of the line intensities of four bands of CO2 around 1.6 and 2.0 μm: A comparison between Fourier transform and diode laser measurements , 2006 .

[23]  B. Parvitte,et al.  Laboratory spectroscopic calibration of infrared tunable laser spectrometers for the in situ sensing of the Earth and Martian atmospheres , 2006 .

[24]  Josef Humlíček,et al.  An efficient method for evaluation of the complex probability function: The Voigt function and its derivatives , 1979 .