Electrochemical and corrosion behavior of two chromium dental alloys in artificial bioenvironments

The purpose of this study is to compare the corrosion and tarnish behavior of NiCrMo and CoCrMo cast dental alloys in artificial bio environments. The cobalt chromium alloys are known and used in dentistry for many years, but its difficult machinability because of the strength and hardness, is an argument for scientists to study alternative materials with comparable biocompatibility. On the other hand, for dentistry devices beside corrosion behavior is important the aesthetic so, the used alloys have to preserve their shining and do not stain. The corrosion resistance has been evaluated using the Atomic mass spectroscopy method for ion release determination, the anodic polarization curves and the open circuit potential – time monitoring for corrosion behavior evaluation and optical microscopy for the structure analysis. The tarnish tendency of alloys was estimated using the method of cyclic immersion with frequency of 10 seconds for each minute during 72 hours in Na 2 S containing solution. The most important conclusion is that the alloys are comparable from corrosion and tarnish point of view, but we recommend to use the nickel base alloy only for orthodontic devices implanted for short periods of time, because of higher quantity of released ions.

[1]  J. Augustyn-Pieniążek,et al.  Corrosion Resistance of Co-Cr-Mo Alloy Used in Dentistry , 2015 .

[2]  K. Chojnacka,et al.  Cytocompatibility of Medical Biomaterials Containing Nickel by Osteoblasts: a Systematic Literature Review , 2010, Biological Trace Element Research.

[3]  H. Hornberger,et al.  A proposal for the classification of dental alloys according to their resistance to corrosion. , 2007, Dental materials : official publication of the Academy of Dental Materials.

[4]  I. Mjör,et al.  The safety of nickel containing dental alloys. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[5]  G. Marshall,et al.  Restorative dental materials: scanning electron microscopy and x-ray microanalysis. , 1988, Scanning microscopy.

[6]  F. A. Peyton,et al.  Effect of Microstructure on the Physical Properties of Cobalt-Base Alloys , 1961, Journal of dental research.

[7]  Yoshimitsu Okazaki,et al.  Comparison of metal release from various metallic biomaterials in vitro. , 2005, Biomaterials.

[8]  S. Miko,et al.  Corrosion behaviour of the Co-Cr-Mo dental alloy in solutions of different composition and different pH values. , 2003, Collegium antropologicum.

[9]  S E Bishara,et al.  Biodegradation of orthodontic appliances. Part I. Biodegradation of nickel and chromium in vitro. , 1993, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.