Online Turn Fault Detection of Interior Permanent-Magnet Machines Using the Pulsating-Type Voltage Injection

This paper proposes a stator winding fault detection for interior permanent-magnet (PM) machines based on the pulsating-type voltage injection. By superimposing a pulsating voltage on d-axis with respect to the rotor-referred synchronous frame, measurable winding fault reflected signals occur in the injection induced current ripples. Comparing to prior diagnostic techniques, the proposed injection method is immune to the rotor saliency because saliency reflected current harmonic is decoupled once the pulsating voltage is exactly injected on rotor d-axis. It results in the improved fault detection performance on interior PM (IPM) machines as well as other salient machines. An IPM machine with three sets of turn-to-turn short is built to verify the proposed fault detection method.

[1]  Report of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I , 1985, IEEE Transactions on Industry Applications.

[2]  T. G. Habetler,et al.  Insulation failure prediction in AC machines using line-neutral voltages , 1998 .

[3]  Paolo Guglielmi,et al.  Impact of cross-saturation in sensorless control of transverse-laminated synchronous reluctance motors , 2006, IEEE Transactions on Industrial Electronics.

[4]  William James Premerlani,et al.  A new approach to on-line turn fault detection in AC motors , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[5]  R.D. Lorenz,et al.  Improved current regulators for IPM machine drives using on-line parameter estimation , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).

[6]  Josep M. Guerrero,et al.  Online diagnostics in inverter-fed induction machines using high-frequency signal injection , 2004, IEEE Transactions on Industry Applications.

[7]  T.G. Habetler,et al.  Stator winding turn-fault detection for closed-loop induction motor drives , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).

[8]  R. M. Tallam,et al.  A robust, on-line turn-fault detection technique for induction machines based on monitoring the sequence component impedance matrix , 2001, 2001 IEEE 32nd Annual Power Electronics Specialists Conference (IEEE Cat. No.01CH37230).

[9]  H.A. Toliyat,et al.  Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review , 2005, IEEE Transactions on Energy Conversion.

[10]  Jung-Ik Ha Analysis of Inherent Magnetic Position Sensors in Symmetric AC Machines for Zero or Low Speed Sensorless Drives , 2008, IEEE Transactions on Magnetics.

[11]  Andrea Bernieri,et al.  On-line fault detection and diagnosis obtained by implementing neural algorithms on a digital signal processor , 1996 .

[12]  Xianghui Huang,et al.  Detection of Rotor Eccentricity Faults in a Closed-Loop Drive-Connected Induction Motor Using an Artificial Neural Network , 2007, IEEE Transactions on Power Electronics.

[13]  Gérard-André Capolino,et al.  Advances in Diagnostic Techniques for Induction Machines , 2008, IEEE Transactions on Industrial Electronics.

[14]  M. W. Degner,et al.  On-line diagnostics in inverter fed induction machines using high frequency signal injection , 2003 .

[15]  S. Sul,et al.  PWM switching frequency signal injection sensorless method in IPMSM , 2011, 2011 IEEE Energy Conversion Congress and Exposition.

[16]  T.G. Habetler Current-based condition monitoring of electrical machines in safety critical applications , 2008, 2008 13th International Power Electronics and Motion Control Conference.

[17]  Youngkook Lee,et al.  A Stator Turn Fault Detection Method and a Fault-Tolerant Operating Strategy for Interior PM Synchronous Motor Drives in Safety-Critical Applications , 2007 .

[18]  R. M. Tallam,et al.  A robust, on-line turn-fault detection technique for induction machines based on monitoring the sequence component impedance matrix , 2003 .

[19]  T.G. Habetler,et al.  Current-based condition monitoring and fault tolerant operation for electric machines in automotive applications , 2007, 2007 International Conference on Electrical Machines and Systems (ICEMS).

[20]  Seung-Ki Sul,et al.  A stator turn-fault detection method for inverter-fed IPMSM with high-frequency current injection , 2013, 2013 IEEE Energy Conversion Congress and Exposition.

[21]  Seung-Ki Sul,et al.  Sensorless Control of IPMSM: Past, Present, and Future , 2012 .