Transport of expiratory droplets in an aircraft cabin.

UNLABELLED The droplets exhaled by an index patient with infectious disease such as influenza or tuberculosis may be the carriers of contagious agents. Indoor environments such as the airliner cabins may be susceptible to infection from such airborne contagious agents. The present investigation computed the transport of the droplets exhaled by the index patient seated in the middle of a seven-row, twin-aisle, fully occupied cabin using the CFD simulations. The droplets exhaled were from a single cough, a single breath, and a 15-s talk of the index patient. The expiratory droplets were tracked by using Lagrangian method, and their evaporation was modeled. It was found that the bulk airflow pattern in the cabin played the most important role on the droplet transport. The droplets were contained in the row before, at, and after the index patient within 30 s and dispersed uniformly to all the seven rows in 4 minutes. The total airborne droplet fraction reduced to 48, 32, 20, and 12% after they entered the cabin for 1, 2, 3, and 4 min, respectively, because of the ventilation from the environmental control system. PRACTICAL IMPLICATIONS It is critical to predict the risk of airborne infection to take appropriate measures to control and mitigate the risk. Most of the studies in past either assume a homogenous distribution of contaminants or use steady-state conditions. The present study instead provides information on the transient movement of the droplets exhaled by an index passenger in an aircraft cabin. These droplets may contain active contagious agents and can be potent enough to cause infection. The findings can be used by medical professionals to estimate the spatial and temporal distribution of risk of infection to various passengers in the cabin.

[1]  Chao-Hsin Lin,et al.  Flow dynamics and characterization of a cough. , 2009, Indoor air.

[2]  P. Höppe,et al.  Temperatures of expired air under varying climatic conditions , 1981, International journal of biometeorology.

[3]  J. Duguid,et al.  The size and the duration of air-carriage of respiratory droplets and droplet-nuclei , 1946, Epidemiology and Infection.

[4]  J. F. Stampfer,et al.  Particle concentration in exhaled breath. , 1987, American Industrial Hygiene Association journal.

[5]  W. Ranz Evaporation from drops : Part II , 1952 .

[6]  S. Orszag,et al.  Renormalization group analysis of turbulence. I. Basic theory , 1986, Physical review letters.

[7]  Chia-Jung Hsu Numerical Heat Transfer and Fluid Flow , 1981 .

[8]  W. E. Ranz,et al.  Evaporation from drops , 1952 .

[9]  M. P. Wan,et al.  Transport and Removal of Expiratory Droplets in Hospital Ward Environment , 2008 .

[10]  Fred Aboosaidi,et al.  Computational Fluid Dynamics Applications in Airplane Cabin Ventilation System Design , 1991 .

[11]  Chao-Hsin Lin,et al.  Characterizing exhaled airflow from breathing and talking. , 2010, Indoor air.

[12]  Q Chen,et al.  Identification of contaminant sources in enclosed spaces by a single sensor. , 2007, Indoor air.

[13]  Zhao Zhang,et al.  Experimental and numerical investigation of airflow and contaminant transport in an airliner cabin mockup , 2009 .

[14]  J. L. Potter,et al.  HUMAN PULMONARY SECRETIONS IN HEALTH AND DISEASE , 1963, Annals of the New York Academy of Sciences.

[15]  K H Dunn,et al.  Numerical simulation of airflow and airborne pathogen transport in aircraft cabins. 1. Numerical simulation of the flow field. , 2005 .

[16]  Qingyan Chen,et al.  Comparison of the Eulerian and Lagrangian methods for predicting particle transport in enclosed spaces , 2007 .

[17]  M. P. Wan,et al.  Modeling the Fate of Expiratory Aerosols and the Associated Infection Risk in an Aircraft Cabin Environment , 2009 .

[18]  Charles DeJohn,et al.  Responding to medical events during commercial airline flights. , 2002, The New England journal of medicine.

[19]  S. Orszag,et al.  Renormalization group analysis of turbulence. I. Basic theory , 1986 .

[20]  M. P. Wan,et al.  Experimental Study of Dispersion and Deposition of Expiratory Aerosols in Aircraft Cabins and Impact on Infectious Disease Transmission , 2009 .

[21]  Kow-Tong Chen,et al.  Transmission of the severe acute respiratory syndrome on aircraft. , 2003, The New England journal of medicine.

[22]  Cover Sheet DROPLET FATE IN INDOOR ENVIRONMENTS , OR CAN WE PREVENT THE SPREAD OF INFECTION ? , 2007 .

[23]  Gerhard Scheuch,et al.  Inhaling to mitigate exhaled bioaerosols. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[24]  A. Mangili,et al.  Review Transmission , 2022 .

[25]  Chao-Hsin Lin,et al.  Optimal Sensor Placement for Airborne Contaminant Detection in an Aircraft Cabin , 2007 .

[26]  Benjamin J. Cowling,et al.  Influenza Virus in Human Exhaled Breath: An Observational Study , 2008, PloS one.

[27]  Wei Yan,et al.  Experimental and CFD study of unsteady airborne pollutant transport within an aircraft cabin mock-up , 2009 .

[28]  Qingyan Chen,et al.  Experimental measurements and numerical simulations of particle transport and distribution in ventilated rooms , 2006 .

[29]  S. Valway,et al.  Tuberculosis and air travel : guidelines for prevention and control , 1998 .

[30]  Zhao Zhang Modeling of airflow and contaminant transport in enclosed environments , 2007 .

[31]  K. Castro,et al.  Transmission of multidrug-resistant Mycobacterium tuberculosis during a long airplane flight. , 1996, The New England journal of medicine.

[32]  Shinhao Yang,et al.  The size and concentration of droplets generated by coughing in human subjects. , 2007, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[33]  Qingyan Chen,et al.  Influence of cabin conditions on placement and response of contaminant detection sensors in a commercial aircraft. , 2008, Journal of environmental monitoring : JEM.