Abstract In 2020, the Centers for Disease Control and Prevention recommended the use of the National Institute for Occupational Safety and Health-certified Elastomeric Half Mask Respirators equipped with N95 or P100 respirator filter cartridges for protection against the SARS-CoV-2 viral agent, as a viable alternative to N95 filtering facepiece respirators. Additionally, the Centers for Disease Control and Prevention recommendations stated that based on current practice, it was acceptable to repeatedly use these filter cartridges for up to 12 months as a contingency capacity strategy during anticipated respirator shortages. To validate this recommendation, an investigation was undertaken in which Elastomeric Half Mask Respirators equipped with P100 respirator filter cartridges were deployed and used by healthcare professionals in clinical settings (i.e., inpatient nursing units, operating rooms) for extended periods. These filter cartridges were subsequently tested to accurately quantify their filtration efficiency and breathing resistance to determine if they continued to meet National Institute for Occupational Safety and Health’s performance requirements. Findings from this investigation confirmed that an Elastomeric Half Mask Respirator when equipped with a P100 filter cartridge continues to provide a high level of aerosol filtration performance (≥99.97%) and exhibits little change in breathing resistance even after 12 months of repeated use (i.e., wear, cleaning, and disinfection between patient use and at the end of work shift) in healthcare settings.
[1]
J. Alper,et al.
Integration of FDA and NIOSH Processes Used to Evaluate Respiratory Protective Devices for Health Care Workers: Proceedings of a Workshop
,
2017
.
[2]
Ronald E Shaffer,et al.
Challenge of N95 Filtering Facepiece Respirators with Viable H1N1 Influenza Aerosols
,
2013,
Infection Control & Hospital Epidemiology.
[3]
Raymond Tellier,et al.
Aerosol transmission of influenza A virus: a review of new studies
,
2009,
Journal of The Royal Society Interface.
[4]
A. Hubbard,et al.
Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
,
2005,
Journal of occupational and environmental hygiene.
[5]
Sheng-Hsiu Huang,et al.
Factors Affecting Filter Penetration and Quality Factor of Particulate Respirators
,
2013
.
[6]
M. Key.
National Institute for Occupational Safety and Health; occupational exposure to inorganic lead: request for comments and information; republication--NIOSH. Request for comments and information relevant to occupational exposure to inorganic lead.
,
1997,
Federal register.