An Efficient Method for Detection of Outliers in Tracer Curves Derived from Dynamic Contrast-Enhanced Imaging

Presence of outliers in tracer concentration-time curves derived from dynamic contrast-enhanced imaging can adversely affect the analysis of the tracer curves by model-fitting. A computationally efficient method for detecting outliers in tracer concentration-time curves is presented in this study. The proposed method is based on a piecewise linear model and implemented using a robust clustering algorithm. The method is noniterative and all the parameters are automatically estimated. To compare the proposed method with existing Gaussian model based and robust regression-based methods, simulation studies were performed by simulating tracer concentration-time curves using the generalized Tofts model and kinetic parameters derived from different tissue types. Results show that the proposed method and the robust regression-based method achieve better detection performance than the Gaussian model based method. Compared with the robust regression-based method, the proposed method can achieve similar detection performance with much faster computation speed.

[1]  T. S. Koh,et al.  Image denoising using robust regression , 2004, IEEE Signal Processing Letters.

[2]  David L Buckley,et al.  Uncertainty in the analysis of tracer kinetics using dynamic contrast‐enhanced T1‐weighted MRI , 2002, Magnetic resonance in medicine.

[3]  Wei-Yun Yau,et al.  A variational formulation for fingerprint orientation modeling , 2012, Pattern Recognit..

[4]  R. Suganya,et al.  Data Mining Concepts and Techniques , 2010 .

[5]  D L Buckley,et al.  Tracer kinetic modelling in MRI: estimating perfusion and capillary permeability , 2012, Physics in medicine and biology.

[6]  Zujun Hou,et al.  Robust edge detection , 2003, Pattern Recognit..

[7]  Thomas S. Huang,et al.  Nonparametric tests for edge detection in noise , 1986, Pattern Recognit..

[8]  R. Wilcox Introduction to Robust Estimation and Hypothesis Testing , 1997 .

[9]  Shang-Hong Lai,et al.  A consensus sampling technique for fast and robust model fitting , 2009, Pattern Recognit..

[10]  P. Tofts Modeling tracer kinetics in dynamic Gd‐DTPA MR imaging , 1997, Journal of magnetic resonance imaging : JMRI.

[11]  C. Thng,et al.  Fundamentals of tracer kinetics for dynamic contrast‐enhanced MRI , 2011, Journal of magnetic resonance imaging : JMRI.

[12]  Stuart B. Heinrich Efficient and robust model fitting with unknown noise scale , 2013, Image Vis. Comput..

[13]  Martin Vetterli,et al.  Adaptive wavelet thresholding for image denoising and compression , 2000, IEEE Trans. Image Process..

[14]  P. Holland,et al.  Robust regression using iteratively reweighted least-squares , 1977 .

[15]  P. J. Huber Robust Regression: Asymptotics, Conjectures and Monte Carlo , 1973 .

[16]  Kenya Murase,et al.  Efficient method for calculating kinetic parameters using T1‐weighted dynamic contrast‐enhanced magnetic resonance imaging , 2004, Magnetic resonance in medicine.