Partial discharge localization in transformer windings using multi-conductor transmission line model

Multi-conductor transmission line model (MTLM) of transformer winding has been used to find partial discharge (PD) location in transformers. To decrease computational complexity of the model, two methods for calculation of model parameters were studied and the most suitable method was chosen based on comparison between measured and calculated transfer functions of a 132 kV/20 kV transformer. To investigate the accuracy of MTLM in PD localization, PD pulses produced by a PD calibrator were injected into different points of a research 20 kV/0.4 kV transformer and measured at both ends of the winding. The sectional winding transfer functions computed by the model were used to refer measured PD signals to possible PD locations. Then by comparison of referred signals, PD location in the winding was estimated.

[1]  Y. Shibuya,et al.  Analysis of very fast transient overvoltage in transformer winding , 1997 .

[2]  P.A. Crossley,et al.  A measurements-based discharge location algorithm for plain disc winding power transformers , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[3]  P.A. Crossley,et al.  Detection and characterisation of partial discharges in transformer defect models , 2002, IEEE Power Engineering Society Summer Meeting,.

[4]  Hossein Borsi,et al.  Transfer function-based partial discharge localization in power transformers: a feasibility study , 2002 .

[5]  Y. Shibuya,et al.  High frequency model and transient response of transformer windings , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[6]  B. T. Phung,et al.  Application of digital filtering techniques to the determination of partial discharge location in transformers , 1989 .

[7]  Peter Crossley,et al.  Simulation of a transformer winding for partial discharge propagation studies , 2002, 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309).

[8]  D. J. Wilcox,et al.  Calculation of self and mutual impedances between sections of transformer windings , 1989 .

[9]  G. C. Paap,et al.  Computation of Very Fast Transient Overvoltages in Transformer Windings , 2002, IEEE Power Engineering Review.

[10]  P. Crossley,et al.  Investigation of propagation of partial discharges in power transformers and techniques for locating the discharge , 2005 .

[11]  K.A. Wirgau Inductance calculation of an air-core disk winding , 1976, IEEE Transactions on Power Apparatus and Systems.

[12]  S.M. Gubanski,et al.  Exploring possibilities for characterization of power transformer insulation by frequency response analysis (FRA) , 2006, IEEE Transactions on Power Delivery.

[13]  Z. D. Wang,et al.  Simulation on propagation of partial discharge pulses in transformer windings , 1998, Proceedings of 1998 International Symposium on Electrical Insulating Materials. 1998 Asian International Conference on Dielectrics and Electrical Insulation. 30th Symposium on Electrical Insulating Ma.

[14]  Peter Crossley,et al.  Experimental investigation into the propagation of partial discharge pulses in transformers , 2002, 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309).

[15]  Bertrand Poulin,et al.  Calculation and measurement of winding disk capacitances with wound-in-shields , 1998 .