Evaluation of modal analysis techniques using physical models to detect osseointegration of implants in transfemoral amputees

Non-invasive vibration analysis has been used extensively to monitor the progression of dental implant healing and stabilization. It is now being considered as a method to monitor femoral implants in transfemoral amputees. This paper evaluates two modal analysis excitation methods and investigates their capabilities in detecting changes at the interface between the implant and the bone that occur during osseointegration. Excitation of bone-implant physical models with the electromagnetic shaker provided higher coherence values and a greater number of modes over the same frequency range when compared to the impact hammer. Differences were detected in the natural frequencies and fundamental mode shape of the model when the fit of the implant was altered in the bone. The ability to detect changes in the model dynamic properties demonstrates the potential of modal analysis in this application and warrants further investigation.

[1]  N Meredith,et al.  The design of a vibration transducer to monitor the integrity of dental implants , 1998, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[2]  K. Hagberg,et al.  Osseointegrated trans-femoral amputation prostheses: Prospective results of general and condition-specific quality of life in 18 patients at 2-year follow-up , 2008, Prosthetics and orthotics international.

[3]  L Sennerby,et al.  Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. , 1997, Clinical oral implants research.

[4]  David L Cochran,et al.  Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. , 2003, The International journal of oral & maxillofacial implants.

[5]  G Van der Perre,et al.  Resonance frequency analysis of implants in the guinea pig model: influence of boundary conditions and orientation of the transducer. , 2007, Medical engineering & physics.

[6]  Martin Groten,et al.  Resonance frequency analysis and damping capacity assessment. Part I: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability. , 2006, Clinical oral implants research.

[7]  F. Shao,et al.  Natural Frequency Analysis of Osseointegration for Trans-femoral Implant , 2007, Annals of Biomedical Engineering.

[8]  Nicola J. Cairns,et al.  The feasibility of vibration analysis as a technique to detect osseointegration of transfemoral implants , 2010 .

[10]  José A. Simões,et al.  Experimental modal analysis of a synthetic composite femur , 2004 .

[11]  B. Rydevik,et al.  Osseointegration in skeletal reconstruction and rehabilitation: a review. , 2001, Journal of rehabilitation research and development.

[12]  Shu Chien,et al.  The Osseointegration Book: From Calvarium to Calcaneus , 2005 .

[13]  N Meredith,et al.  Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. , 1996, Clinical oral implants research.