PWM Control of a Cooling Tower in a Thermally Homeostatic Building

Thermal Homeostasis in Buildings (THiB) is a new concept of building conditioning. Since summer cooling is the more challenging of building conditioning, several earlier papers focused on the study of natural summer cooling by using cooling tower (CT). The goal was to show the possibility and conditions of natural cooling, i.e., under what extreme day by day conditions that it is still possible for natural cooling to keep indoor temperature from exceeding a given maximum value: since no consideration was given to limiting indoor temperature above a minimum, in fact CT overcooling would be the problem for most part of the summer. This paper presents a fuller consideration of continual operation of a CT throughout the whole summer with pulse-width modulation (PWM) control of the tower operation. The goal here is to find to what extent the indoor temperature can be kept within the comfort zone. To put it another way, determine whether hours or percentile of hours out of total annual hours that the operative temperatures are out of the comfort zone are acceptable or not in a small sample of cities.

[1]  lin-shu wang,et al.  Effective heat capacity of interior planar thermal mass (iPTM) subject to periodic heating and cooling , 2012 .

[2]  Viktor Dorer,et al.  Thermally activated building systems (TABS): Energy efficiency as a function of control strategy, hydronic circuit topology and (cold) generation system , 2011 .

[3]  Viktor Dorer,et al.  Application range of thermally activated building systems tabs , 2007 .

[4]  Lin-Shu Wang,et al.  Energy storage and heat extraction – From thermally activated building systems (TABS) to thermally homeostatic buildings , 2015 .

[5]  Lin-Shu Wang,et al.  Modeling of hydronic radiant cooling of a thermally homeostatic building using a parametric cooling tower , 2014 .

[6]  Lin-Shu Wang,et al.  Modeling of TABS-based thermally manageable buildings in Simulink , 2013 .

[7]  Lin-Shu Wang,et al.  Low-grade heat and its definitions of Coefficient-of-Performance (COP) , 2015 .

[8]  Lin-Shu Wang,et al.  A study of building envelope and thermal mass requirements for achieving thermal autonomy in an office building , 2014 .

[9]  Lin-Shu Wang,et al.  Design of a Thermally Homeostatic Building and Modeling of Its Natural Radiant Cooling Using Cooling Tower , 2015 .

[10]  Bjarne W. Olesen,et al.  Thermo Active Building Systems - Using Building Mass To Heat and Cool , 2012 .

[11]  Lin-Shu Wang,et al.  Maximum window-to-wall ratio of a thermally autonomous building as a function of envelope U-value and ambient temperature amplitude , 2015 .

[12]  Viktor Dorer,et al.  Control of thermally-activated building systems (TABS) , 2008 .

[13]  Lin-Shu Wang,et al.  The homeostasis solution – Mechanical homeostasis in architecturally homeostatic buildings , 2016 .