Imaging Particulate Two-Phase Flow in Liquid Suspensions with Electric Impedance Tomography

Different approaches have been followed to model the hydraulic transport of particles, ranging from pure empirical correlations to general models based on fundamental principles. However, these models suffer from uncertainties associated with the parameters in the constitutive equations and scarcity of experimental data in the literature. Nonintrusive techniques such as electric impedance tomography (EIT) can be used to circumvent the difficulties associated with sampling techniques. EIT is an imaging technique for the phase distribution in a two-phase flow field, allowing reconstructing the resistivity/conductivity distribution gradients from electrical data in a medium subjected to arbitrary excitations. Our best efforts were concentrated on the development of a new EIT system that is analogue based, portable, low-cost, and capable of providing high-quality sharp images when used to characterize the flow of particle suspensions. A voltage source was used, rather than a more complex and costly current source, since it provided the EIT system with a more precise and flexible current output. The data acquisition system consists of 16 electrodes equally spaced in the boundary of a tube and a custom dedicated electronic apparatus. The software supplies results in the form of two-dimensional reconstructed images that allow mapping the phase distribution inside the tube.

[1]  Manuchehr Soleimani,et al.  A DSP Based Multi-Frequency 3D Electrical Impedance Tomography System , 2008, Annals of Biomedical Engineering.

[2]  A. J. Wilkinson,et al.  The design of an ERT system for 3D data acquisition and a quantitative evaluation of its performance , 2006 .

[3]  Sharath Subash Donthi Capacitance based Tomography for Industrial Applications , 2004 .

[4]  Shahzad Barghi,et al.  Application of electrical resistance tomography on liquid–solid two-phase flow characterization in an LSCFB riser , 2009 .

[5]  Guizhi Xu,et al.  Multi-frequency EIT Hardware System Based on DSP , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[6]  D. Isaacson,et al.  Electrode models for electric current computed tomography , 1989, IEEE Transactions on Biomedical Engineering.

[7]  Marko Vauhkonen,et al.  Electrical impedance tomography and prior information , 1997 .

[8]  H. I. Schlaberg,et al.  A novel tomographic sensing system for high electrically conductive multiphase flow measurement , 2010 .

[9]  D. R. Adkins,et al.  Advanced tomographic flow diagnostics for opaque multiphase fluids , 1997 .

[10]  John G. Webster,et al.  An Impedance Camera for Spatially Specific Measurements of the Thorax , 1978, IEEE Transactions on Biomedical Engineering.

[11]  R. Granit THE HEART ( Extract from “ Principles and Applications of Bioelectric and Biomagnetic Fields , 2005 .

[12]  B. Brown,et al.  Applied potential tomography. , 1989, Journal of the British Interplanetary Society.

[13]  Steven L. Ceccio,et al.  Electrical-Impedance Tomography for Opaque Multiphase Flows in Metallic (Electrically-Conducting) Vessels , 2002 .

[14]  Tom Dyakowski,et al.  A Dual Modality Tomography System for Imaging Gas/Solids Flows , 2006 .

[15]  Philip K. Chan,et al.  Using electrical resistance tomography and computational fluid dynamics modeling to study the formation of cavern in the mixing of pseudoplastic fluids possessing yield stress , 2008 .

[16]  Trevor A. York Status of electrical tomography in industrial applications , 2001, J. Electronic Imaging.

[17]  C. J. Grootveld Measuring & modeling of concentrated settling suspensions using electrical impedance tomography , 1996 .

[18]  Boris Rubinsky,et al.  Frequency-Division Multiplexing for Electrical Impedance Tomography in Biomedical Applications , 2007, Int. J. Biomed. Imaging.

[19]  J.P. Kaipio,et al.  Three-dimensional electrical impedance tomography based on the complete electrode model , 1999, IEEE Transactions on Biomedical Engineering.

[20]  T. F. Jones,et al.  Visualization of Asymmetric Solids Distribution in Horizontal Swirling Flows Using Electrical Resistance Tomography , 2003 .

[21]  Marko Vauhkonen,et al.  Real time three-dimensional electrical impedance tomography applied in multiphase flow imaging , 2006 .

[22]  Fernando Garcia,et al.  Flow dynamics of pulp fiber suspensions , 2008, August 2008.

[23]  R.A. Williams,et al.  A high-performance EIT system , 2005, IEEE Sensors Journal.

[24]  William R B Lionheart,et al.  A Matlab toolkit for three-dimensional electrical impedance tomography: a contribution to the Electrical Impedance and Diffuse Optical Reconstruction Software project , 2002 .

[25]  Jari P. Kaipio,et al.  Tikhonov regularization and prior information in electrical impedance tomography , 1998, IEEE Transactions on Medical Imaging.

[26]  Wuqiang Yang Tomographic Imaging based on Capacitance Measurement and Industrial Applications , 2007, 2007 IEEE International Workshop on Imaging Systems and Techniques.

[27]  Jeff Peakall,et al.  Electrical Resistance Tomography for Suspended Sediment Measurements in Open Channel Flows Using a Novel Sensor Design , 2006 .

[28]  Mi Wang,et al.  Impedance mapping of particulate multiphase flows , 2005 .