The response of steel-framed structures to applied loading depends to a large degree
on the behaviour of the joints between the columns and beams. Traditionally
designers have assumed that these joints act either as 'pinned', with no ability to
transmit moments from beam to column, or as 'rigid', providing perfect continuity
between the connected members. Advances in analysis, and developments in
modem codes of practice, permit designers to account for the real behaviour of steel
joints where this is known or can be predicted. Even though experimental studies of
joints conducted at many research centres around the world have provided a large
bank of test data, the vast number of variables in joints (beam and column sizes, plate
thicknesses, bolt sizes and spacing, etc.) often means that data for a specific joint
arrangement does not exist. As a result, researchers have turned their attention to
ways of predicting the behaviour of such joints. One approach which has gained
acceptance is based on the "Component Method" in which overall joint behaviour is
assumed to be produced by the responses of its various simpler components.
To date, data on the response of joints at elevated temperatures has been gathered
from full-scale furnace tests on cruciform arrangements, which have concentrated
exclusively on moment-rotation behaviour in the absence of axial thrusts. However,
when steel-framed structures are subjected to fire, the behaviour of the joints within
the overall frame response is greatly affected by the high axial forces which are
created by restraint to the thermal expansion of unprotected beams. If momentrotation-
thrust surfaces were to be generated this process would require prohibitive
numbers of complex and expensive furnace tests for each joint configuration. The
alternative, and more practical, method is to extend the Component Method to the
elevated-temperature situation.
The basic theme of the Component Method is to consider any joint as an assembly of
individual simple components. Each of these components is simply a non-linear
spring, possessing its own level of strength and stiffness in tension, compression or
shear, and these will degrade as its temperature rises. The main objective of this
study was to investigate experimentally and analytically the behaviour of tension and
compression zones of end-plate connections at elevated temperatures. A series of
experiments has been carried out and a simplified analytical model has been
developed, and this has been validated against the tests and against detailed finite
element simulations. The simplified model is shown to be very reliable for this very
common type of joint, although similar methods will need to be developed for other
configurations. The principles of the Component Method can be used directly in
either simplified or finite element modelling, without attempting to predict of the
overall joint behaviour in fire, to enable semi-rigid behaviour to be taken into
account in the analytical fire engineering design of steel-framed and composite
buildings.