Secondary subconjunctival implantation of a biodegradable collagen-glycosaminoglycan matrix to treat ocular hypotony following trabeculectomy with mitomycin C

Aim Biodegradable collagen glycosaminoglycan matrices (CGM) have been introduced to glaucoma filtration surgery in order to prevent scarring of the filtering bleb. In this retrospective case series, we describe a new surgical concept for treating symptomatic ocular hypotony following filtration surgery with mitomycin C by a secondary subconjunctival implantation of a CGM. Methods Depending on bleb morphology, a CGM implant with a diameter of 6 or 12 mm was placed subconjunctivally on the scleral flap in 12 eyes displaying symptomatic ocular hypotony with (n=2) or without (n=10) bleb leakage. Median period between trabeculectomy and this intervention was 4.5 months (range, 1−72 months). Results Mean intraocular pressure significantly increased from 4.4±1.4 mm Hg to 9.9±2.8 mm Hg (p<0.0001) over a median follow-up of 6 months (range, 2−18 months). Mean visual acuity improved significantly (p=0.0012). Postoperative complications included implant re-exposure in one eye and persistent choroidal detachment requiring resurgery in another eye. Conclusions Subconjunctival implantation of CGM may present an additional surgical tool in the treatment of symptomatic ocular hypotony after filtering surgery. The mechanism of action may be counter-pressure to the scleral flap and secondary wound healing around the CGM scaffold. Long-term observations are needed to fully evaluate this new surgical concept.

[1]  T. Dada,et al.  Trabeculectomy With Combined Use of Subconjunctival Collagen Implant and Low-dose Mitomycin C , 2013, Journal of glaucoma.

[2]  Jung Kee Min,et al.  Surgical Outcome of Mitomycin C-soaked Collagen Matrix Implant in Trabeculectomy , 2013, Journal of glaucoma.

[3]  A. Azuara-Blanco,et al.  Interventions for late trabeculectomy bleb leak. , 2012, The Cochrane database of systematic reviews.

[4]  Semon Wu,et al.  The application of tissue engineering in reversing mitomycin C-induced ischemic conjunctiva. , 2012, Journal of biomedical materials research. Part A.

[5]  T. Dietlein,et al.  Biodegradable Implant for Tissue Repair After Glaucoma Drainage Device Surgery , 2012, Journal of glaucoma.

[6]  J. Myers Biodegradable collagen matrix implant vs mitomycin-C as an adjuvant in trabeculectomy: a 24-month, randomized clinical trial , 2012 .

[7]  L. Vijaya,et al.  Outcomes of Bleb Excision With Free Autologous Conjunctival Patch Grafting for Bleb Leak and Hypotony After Glaucoma Filtering Surgery , 2011, Journal of glaucoma.

[8]  G. Krieglstein,et al.  A prospective randomised trial of trabeculectomy using mitomycin C vs an ologen implant in open angle glaucoma , 2010, Eye.

[9]  P. So,et al.  Biologically active collagen-based scaffolds: advances in processing and characterization , 2010, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[10]  I. Georgalas,et al.  Trabeculectomy with OloGen versus trabeculectomy for the treatment of glaucoma: a pilot study , 2010, Acta ophthalmologica.

[11]  P. Denis,et al.  Ultrasound Biomicroscopy and Optical Coherence Tomography Imaging of Filtering Blebs after Deep Sclerectomy with New Collagen Implant , 2009, European journal of ophthalmology.

[12]  R. Ritch,et al.  Tissue bioengineering for surgical bleb defects: an animal study , 2008, Graefe's Archive for Clinical and Experimental Ophthalmology.

[13]  R. Ritch,et al.  Control of filtering bleb structure through tissue bioengineering: An animal model. , 2006, Investigative ophthalmology & visual science.

[14]  N. Harizman,et al.  Donor Scleral Patch for Treating Hypotony Due to Leaking and/or Overfiltering Blebs , 2005, Journal of glaucoma.

[15]  T. Higashide,et al.  Intraoperative Healon5 injection into blebs for small conjunctival breaks created during trabeculectomy , 2005, Journal of cataract and refractive surgery.

[16]  J. Caprioli,et al.  Outcomes of bleb excision and conjunctival advancement for leaking or hypotonous eyes after glaucoma filtering surgery , 2003, The British journal of ophthalmology.

[17]  S. Shirato,et al.  Resuturing the scleral flap through conjunctiva for treatment of excess filtration. , 2004, American journal of ophthalmology.

[18]  S. Nainiwal,et al.  Autologous blood injection for late-onset filtering bleb leak. , 2002, American journal of ophthalmology.

[19]  L. Cantor,et al.  Autologous blood injection for late-onset filtering bleb leak. , 2001, American journal of ophthalmology.

[20]  P. Rubin,et al.  Inhibition of conjunctival scarring and contraction by a porous collagen-glycosaminoglycan implant. , 2000, Investigative ophthalmology & visual science.

[21]  P. Khaw,et al.  Transforming Growth Factor-β1, -β2, and -β3 In Vivo: Effects on Normal and Mitomycin C–Modulated Conjunctival Scarring , 1999 .

[22]  D. Budenz,et al.  Conjunctival advancement for late-onset filtering bleb leaks: indications and outcomes. , 1999, Archives of ophthalmology.

[23]  P. Khaw,et al.  Transforming growth factor-beta1, -beta2, and -beta3 in vivo: effects on normal and mitomycin C-modulated conjunctival scarring. , 1999, Investigative ophthalmology & visual science.

[24]  W. Alward,et al.  Rapid Visual Recovery and Long‐Term Intraocular Pressure Control After Donor Scleral Patch Grafting for Trabeculectomy‐Induced Hypotony Maculopathy , 1995, Journal of glaucoma.

[25]  M. F. Smith,et al.  Treatment of postfiltration bleb leaks with autologous blood. , 1995, Ophthalmology.

[26]  P. Khaw,et al.  Prolonged localized tissue effects from 5-minute exposures to fluorouracil and mitomycin C. , 1993, Archives of ophthalmology.

[27]  R. Hitchings,et al.  Clinico pathological correlation in eyes with failed fistulizing surgery. , 1983, Transactions of the ophthalmological societies of the United Kingdom.