Toward multi‐analyte bioarray sensors: LAPS‐based on‐chip determination of a Michaelis–Menten‐like kinetics for cell culturing

The metabolic activity of Chinese hamster ovary (CHO) cells was observed using a light-addressable potentiometric sensor (LAPS). The dependency toward different glucose concentrations (17–200 mM) follows a Michaelis–Menten kinetics trajectory with Km = 32.8 mM, and the obtained Km value in this experiment was compared with that found in literature. In addition, the pH shift induced by glucose metabolism of tumor cells transfected with the HPV-16 genome (C3 cells) was successfully observed. These results indicate the possibility to determine the tumor cells metabolism with a LAPS-based measurement device.

[1]  J. W. Parce,et al.  Biosensors based on the energy metabolism of living cells: the physical chemistry and cell biology of extracellular acidification. , 1992, Biosensors & bioelectronics.

[2]  T. Yoshinobu,et al.  "All-in-one" solid-state device based on a light-addressable potentiometric sensor platform , 2005, The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05..

[3]  R. Hill,et al.  The tumor microenvironment and metastatic disease , 2008, Clinical & Experimental Metastasis.

[4]  Y. Ermolenko,et al.  The light-addressable potentiometric sensor for multi-ion sensing and imaging. , 2005, Methods.

[5]  J. W. Parce,et al.  The light-addressable potentiometric sensor: principles and biological applications. , 1994, Annual review of biophysics and biomolecular structure.

[6]  I. Karube,et al.  BIOSENSORS BASED ON LIGHT-ADDRESSABLE POTENTIOMETRIC SENSORS FOR UREA, PENICILLIN AND GLUCOSE , 1998 .

[7]  J. W. Parce,et al.  Light-addressable potentiometric sensor for biochemical systems. , 1988, Science.

[8]  Michael J. Schöning,et al.  PLD-prepared cadmium sensors based on chalcogenide glasses—ISFET, LAPS and μISE semiconductor structures , 2006 .

[9]  Hiroshi Iwasaki,et al.  Constant-Current-Mode LAPS (CLAPS) for the Detectionof Penicillin , 2001 .

[10]  Willi Zander,et al.  Copper, cadmium and thallium thin film sensors based on chalcogenide glasses , 2001 .

[11]  Michael J. Schöning,et al.  Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS? , 2001 .

[12]  F. Hafner,et al.  Cytosensor Microphysiometer: technology and recent applications. , 2000, Biosensors & bioelectronics.

[13]  Michael J. Schöning,et al.  Nutrient concentration‐sensitive microorganism‐based biosensor , 2012 .

[14]  O. Warburg [Origin of cancer cells]. , 1956, Oncologia.

[15]  M. Feltkamp,et al.  Vaccination with cytotoxic T lymphocyte epitope‐containing peptide protects against a tumor induced by human papillomavirus type 16‐transformed cells , 1993, European journal of immunology.

[16]  Hiroshi Iwasaki,et al.  Portable light-addressable potentiometric sensor (LAPS) for multisensor applications , 2003 .

[17]  Michael J. Schöning,et al.  Development of a handheld 16 channel pen-type LAPS for electrochemical sensing , 2005 .

[18]  Michael J. Schöning,et al.  Handheld multi-channel LAPS device as a transducer platform for possible biological and chemical multi-sensor applications , 2007 .