In vivo inflammatory and wound healing effects of gold electrode voltammetry for MEMS micro-reservoir drug delivery device

The in vivo biocompatibility and biofouling of gold electrodes for a microelectromechanical systems drug delivery device were investigated in a rodent model. The role of the applied voltage and gold electrolysis products in modulating the inflammatory response (biocompatibility), and the temporal adhesion of cellular populations onto macroscopic gold film electrodes (biofouling) were analyzed in reference to two controls, devices to which voltage was not applied (uncorroded) or voltage was applied to inert platinum electrodes (electrical controls). Voltammetry was applied to the gold surfaces once (day 4, 7, 14, 21, 28, 35, 42, or 49), while voltage of identical magnitude was applied to the electrical controls. An inflammatory response characterized by a rapid decrease of leukocyte concentration to control levels was observed 48 h following voltage application with no significant cell concentration difference (p>0.05) between the corroded devices and electrical controls. The histological evaluation of the direct implant fibrous capsule showed comparable thickness of voltage applied and control specimens. The gold corrosion peak current showed no significant difference (p>0.05) among peak values at all time points. It was concluded that gold electrode corrosion was biocompatible and its electrochemical performance was not hindered by fibrous capsule formation.

[1]  Rebecca S. Shawgo,et al.  Biocompatibility and biofouling of MEMS drug delivery devices. , 2003, Biomaterials.

[2]  M. Cima,et al.  A controlled-release microchip , 1999, Nature.

[3]  J M Anderson,et al.  Shear stress effects on bacterial adhesion, leukocyte adhesion, and leukocyte oxidative capacity on a polyetherurethane. , 1999, Journal of biomedical materials research.

[4]  J M Anderson,et al.  Generation of IL-1-like activity in response to biomedical polymer implants: a comparison of in vitro and in vivo models. , 1989, Journal of biomedical materials research.

[5]  G. Gentzkow,et al.  Electrical stimulation to heal dermal wounds. , 1993, The Journal of dermatologic surgery and oncology.

[6]  B Merchant,et al.  Gold, the noble metal and the paradoxes of its toxicology. , 1998, Biologicals : journal of the International Association of Biological Standardization.

[7]  J M Anderson,et al.  In vitro cytotoxicity and in vivo biocompatibility of poly(propylene fumarate-co-ethylene glycol) hydrogels. , 1999, Journal of biomedical materials research.

[8]  James M. Anderson,et al.  Generation of IL1-like activity in response to biomedical polymer implants: a comparison of in vitro and in vivo models , 1989 .

[9]  Denny A. Jones Principles and prevention of corrosion , 1991 .

[10]  Raphael C. Lee,et al.  Integrin-Dependent Human Macrophage Migration Induced by Oscillatory Electrical Stimulation , 2000, Annals of Biomedical Engineering.

[11]  Gentzkow Gd,et al.  Electrical stimulation for dermal wound healing. , 1991 .

[12]  Peter J. Sadler,et al.  Gold drugs: Mechanism of action and toxicity , 1996 .