Transversal phase resolved polarization sensitive optical coherence tomography

We present a novel optical coherence tomography (OCT) method to measure backscattered intensity and birefringence properties (retardation and fast axis orientation) and apply it to imaging of human ocular tissue. The method is based on a Mach Zehnder interferometer, on transversal scanning, and on a polarization sensitive two-channel detection. A highly stable carrier frequency is generated by acousto-optic modulators (AOMs). This allows a phase sensitive demodulation by the lock-in technique. Since the recording of individual interference fringes is avoided by this method the amount of data to be recorded and processed is considerably reduced. We demonstrate this method on human cornea and anterior chamber angle and present, to the best of our knowledge, the first OCT images of retardation and fast axis orientation of the anterior chamber angle region in vivo.

[1]  J. Fujimoto,et al.  Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging , 1992 .

[2]  A. Fercher,et al.  Chapter 4 – Optical coherence tomography , 2002 .

[3]  A. Fercher,et al.  Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography. , 2001, Optics express.

[4]  Theo Lasser,et al.  Video-rate three-dimensional optical coherence tomography. , 2002, Optics express.

[5]  M. Akiba,et al.  Full-field optical coherence tomography by two-dimensional heterodyne detection with a pair of CCD cameras. , 2003, Optics letters.

[6]  David J. Webb,et al.  Transversal and longitudinal images from the retina of the living eye using low coherence reflectometry. , 1998, Journal of biomedical optics.

[7]  Barry Cense,et al.  Real-time multi-functional optical coherence tomography. , 2003, Optics express.

[8]  Adolf F. Fercher,et al.  Imaging of polarization properties of the human cornea with phase-resolved polarization-sensitive optical coherence tomography , 2003, SPIE BiOS.

[9]  Qienyuan Zhou,et al.  Three-dimensional imaging of the human retina by high-speed optical coherence tomography. , 2003, Optics express.

[10]  Zhongping Chen,et al.  Determination of the depth-resolved Stokes parameters of light backscattered from turbid media by use of polarization-sensitive optical coherence tomography. , 1999, Optics letters.

[11]  David A. Jackson,et al.  En-face coherence imaging using galvanometer scanner modulation. , 1998, Optics letters.

[12]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[13]  J. Izatt,et al.  Real-time optical coherence tomography of the anterior segment at 1310 nm. , 2001, Archives of ophthalmology.

[14]  Lihong V. Wang,et al.  Jones-matrix imaging of biological tissues with quadruple-channel optical coherence tomography. , 2002, Journal of biomedical optics.

[15]  M. V. van Gemert,et al.  Two-dimensional birefringence imaging in biological tissue using polarization-sensitive optical coherence tomography , 1997, European Conference on Biomedical Optics.

[16]  B. Colston,et al.  Birefringence characterization of biological tissue by use of optical coherence tomography. , 1998, Optics letters.

[17]  Adolf F. Fercher,et al.  Three-dimensional polarization-sensitive optical coherence tomography of normal and pathologic human cornea , 2003, European Conference on Biomedical Optics.

[18]  K. Meek,et al.  The integration of the corneal and limbal fibrils in the human eye. , 1998, Biophysical journal.

[19]  Vincent Loriette,et al.  Full-field birefringence imaging by thermal-light polarization-sensitive optical coherence tomography. II. Instrument and results. , 2003, Applied optics.

[20]  J. Nelson,et al.  High-speed fiber based polarization-sensitive optical coherence tomography of in vivo human skin. , 2000, Optics letters.