The dynamic range of digital radiographic systems: dose reduction or risk of overexposure?

OBJECTIVES To investigate the range of diagnostically acceptable digital radiographs and film as a function of exposure time, as well as the relationship to dose reduction and consequences for dental practice. METHODS Five systems for intraoral radiography were used to take a series of radiographs, with increasing exposure times, of five different dry bone specimens. Seven observers evaluated the 25 series of radiographs. The observers had to determine which radiographs of each series were acceptable for dental diagnostics and which radiograph of each series they preferred. RESULTS For Ektaspeed Plus film, the exposure time for the preferred radiograph was 0.52 s, with a range of diagnostically acceptable radiographs from 0.23-1.02 s. The preferred radiograph of the solid-state systems required less radiation than film (Sirona, 0.13 s; MPDx 0.35 s). The exposure range of these systems is narrow. In contrast, the exposure range of the phosphor plate systems is very wide. The preferred radiograph of the phosphor plate systems required high exposure (Digora, 1.21 s; Gendex DenOptix, 1.16 s). CONCLUSIONS All digital systems require less exposure than film for diagnostically acceptable radiographs, but this is less obvious for preferred radiographs. Solid-state systems alert the dentist when a too long exposure time is used by a lack of image quality; phosphor plate systems, however, produce good quality radiographs even at high exposure times, which may result in an unnecessarily high dose.

[1]  G C Sanderink,et al.  Radiographic detection of approximal caries: a comparison of dental films and digital imaging systems. , 2000, Dento maxillo facial radiology.

[2]  P. van der Stelt,et al.  Does digital radiography increase the number of intraoral radiographs? A questionnaire study of Dutch dental practices. , 2003, Dento maxillo facial radiology.

[3]  H. Gröndahl,et al.  Film and digital radiography for detection of simulated root resorption cavities. , 1998, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[4]  A Wenzel,et al.  Experience of Norwegian general dental practitioners with solid state and storage phosphor detectors. , 2001, Dento maxillo facial radiology.

[5]  H G Gröndahl,et al.  Subjective image quality of solid-state and photostimulable phosphor systems for digital intra-oral radiography. , 2000, Dento maxillo facial radiology.

[6]  K. F. Lim,et al.  Intra-oral computed radiography--an in vitro evaluation. , 1996, Journal of dentistry.

[7]  Y. Hayakawa,et al.  Radiation dosage reduction in general dental practice using digital intraoral radiographic systems. , 1997, The Bulletin of Tokyo Dental College.

[8]  G C Sanderink,et al.  Dose reduction of two digital sensor systems measuring file lengths. , 1996, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[9]  D S Brettle,et al.  A practical approach to soft-copy display consistency for PC-based review workstations. , 2003, The British journal of radiology.

[10]  G C H Sanderink,et al.  A comparison of digital and film radiography in Dutch dental practices assessed by questionnaire. , 2002, Dento maxillo facial radiology.

[11]  C F Hildebolt,et al.  Dental photostimulable phosphor radiography. , 2000, Dental clinics of North America.

[12]  C H Versteeg,et al.  Impact of scale standardization on images of digital radiography systems. , 1997, Dento maxillo facial radiology.

[13]  A. Wenzel,et al.  Decision criteria and characteristics of Norwegian general dental practitioners selecting digital radiography. , 2001, Dento maxillo facial radiology.

[14]  A. Wenzel,et al.  Effect of exposure time on in vitro caries diagnosis using the Digora system. , 1997, European journal of oral sciences.

[15]  H. Gröndahl,et al.  On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems. , 1996, Dento maxillo facial radiology.

[16]  C H Versteeg,et al.  Reduction in size of digital images: does it lead to less detectability or loss of diagnostic information? . , 1998, Dento maxillo facial radiology.

[17]  M. Frydenberg,et al.  Accuracy of caries detection with four storage phosphor systems and E-speed radiographs. , 2002, Dento maxillo facial radiology.

[18]  G C Sanderink,et al.  Intraoral detectors. CCD, CMOS, TFT, and other devices. , 2000, Dental clinics of North America.

[19]  T. Macfarlane,et al.  Three phosphor plate systems and film compared for imaging root canals. , 2001, International endodontic journal.