Design and Fabrication of a High-Performance Electrochemical Glucose Sensor

Objective: Development of electrochemical sensors for continuous glucose monitoring is currently hindered by a variety of problems associated with low selectivity, low sensitivity, narrow linearities, delayed response times, hysteresis, biofouling, and tissue inflammation. We present an optimized sensor architecture based on layer stratification, which provides solutions that help address the aforementioned issues. Method: The working electrode of the electrochemical glucose sensors is sequentially coated with five layers containing: (1) electropolymerized polyphenol (PPh), (2) glutaraldehyde-immobilized glucose oxidase (GOx) enzyme, (3) dip-coated polyurethane (PU), (4) glutaraldehyde-immobilized catalase enzyme, and (5) a physically cross linked polyvinyl alcohol (PVA) hydrogel membrane. The response of these sensors to glucose and electroactive interference agents (i.e., acetaminophen) was investigated following application of the various layers. Sensor hysteresis (i.e., the difference in current for a particular glucose concentration during ascending and descending cycles after 200 s) was also investigated. Results: The inner PPh membrane improved sensor selectivity via elimination of electrochemical interferences, while the third PU layer afforded high linearity by decreasing the glucose-to-O2 ratio. The fourth catalase layer improved sensor response time and eliminated hysteresis through active withdrawal of GOx-generated H2O2 from the inner sensory compartments. The outer PVA hydrogel provided mechanical support and a continuous pathway for diffusion of various participating species while acting as a host matrix for drug-eluting microspheres. Conclusions: Optimal sensor performance has been achieved through a five-layer stratification, where each coating layer works complementarily with the others. The versatility of the sensor design together with the ease of fabrication renders it a powerful tool for continuous glucose monitoring.

[1]  C. Choi,et al.  Glucose sensor using a microfabricated electrode and electropolymerized bilayer films. , 2002, Biosensors & bioelectronics.

[2]  P. Hoet,et al.  Nanoparticles – known and unknown health risks , 2004, Journal of nanobiotechnology.

[3]  Joseph Wang,et al.  In vivo glucose monitoring: towards 'Sense and Act' feedback-loop individualized medical systems. , 2008, Talanta.

[4]  Santhisagar Vaddiraju,et al.  Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises , 2010, Journal of diabetes science and technology.

[5]  P. Nicholls,et al.  Enzymology and structure of catalases , 2000 .

[6]  Santhisagar Vaddiraju,et al.  Emerging synergy between nanotechnology and implantable biosensors: a review. , 2010, Biosensors & bioelectronics.

[7]  Alexander M. Yacynych,et al.  Electropolymerized films to prevent interferences and electrode fouling in biosensors , 1991 .

[8]  W M Reichert,et al.  Vascular endothelial growth factor and dexamethasone release from nonfouling sensor coatings affect the foreign body response. , 2007, Journal of biomedical materials research. Part A.

[9]  Joseph Wang Carbon‐Nanotube Based Electrochemical Biosensors: A Review , 2005 .

[10]  G. S. Wilson,et al.  Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring. , 1991, Analytical chemistry.

[11]  Diane J Burgess,et al.  Concurrent delivery of dexamethasone and VEGF for localized inflammation control and angiogenesis. , 2007, Journal of controlled release : official journal of the Controlled Release Society.

[12]  Fotios Papadimitrakopoulos,et al.  Biomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body Response , 2010, The AAPS Journal.

[13]  Fotios Papadimitrakopoulos,et al.  A Review of the Biocompatibility of Implantable Devices: Current Challenges to Overcome Foreign Body Response , 2008, Journal of diabetes science and technology.

[14]  G. S. Wilson,et al.  Biosensors for real-time in vivo measurements. , 2005, Biosensors & bioelectronics.

[15]  Fotios Papadimitrakopoulos,et al.  Layer-by-Layer Assembled Semipermeable Membrane for Amperometric Glucose Sensors , 2007, Journal of diabetes science and technology.

[16]  Santhisagar Vaddiraju,et al.  Enhanced Glucose Sensor Linearity Using Poly(Vinyl Alcohol) Hydrogels , 2009, Journal of diabetes science and technology.

[17]  C. Lowe,et al.  Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers. , 1988, Analytical chemistry.

[18]  Robert H. Hurt,et al.  Toxicology of carbon nanomaterials: Status, trends, and perspectives on the special issue , 2006 .

[19]  Joseph Wang,et al.  Glucose Biosensors : 40 Years of Advances and Challenges , 2001 .

[20]  A Heller,et al.  Implanted electrochemical glucose sensors for the management of diabetes. , 1999, Annual review of biomedical engineering.

[21]  Wisniewski,et al.  Methods for reducing biosensor membrane biofouling. , 2000, Colloids and surfaces. B, Biointerfaces.

[22]  Joseph Wang Electrochemical glucose biosensors. , 2008, Chemical reviews.

[23]  Fotios Papadimitrakopoulos,et al.  Controlling Acute Inflammation with Fast Releasing Dexamethasone-PLGA Microsphere/PVA Hydrogel Composites for Implantable Devices , 2007, Journal of diabetes science and technology.

[24]  Fotios Papadimitrakopoulos,et al.  PLGA/PVA hydrogel composites for long-term inflammation control following s.c. implantation. , 2010, International journal of pharmaceutics.

[25]  M. Muir Physical Chemistry , 1888, Nature.

[26]  Joseph Wang,et al.  Electrochemical biosensors: towards point-of-care cancer diagnostics. , 2006, Biosensors & bioelectronics.

[27]  Francis Moussy,et al.  Use of hydrogel coating to improve the performance of implanted glucose sensors. , 2008, Biosensors & bioelectronics.

[28]  Adam Heller,et al.  Sources of instability of ‘wired’ enzyme anodes in serum: urate and transition metal ions , 2001 .

[29]  A. Turner,et al.  Ferrocene-mediated enzyme electrode for amperometric determination of glucose. , 1984, Analytical chemistry.

[30]  J. Robert,et al.  Continuous Monitoring of Blood Glucose , 2004, Hormone Research in Paediatrics.

[31]  B. E. Watt,et al.  Hydrogen Peroxide Poisoning , 2004, Toxicological reviews.

[32]  I. Macdonald,et al.  Hypoglycaemia, hypothermia and shivering in man. , 1981, Clinical science.

[33]  F. Papadimitrakopoulos,et al.  The role of H2O2 outer diffusion on the performance of implantable glucose sensors. , 2009, Biosensors & bioelectronics.

[34]  W. Tamborlane,et al.  A tale of two compartments: interstitial versus blood glucose monitoring. , 2009, Diabetes technology & therapeutics.

[35]  Fotios Papadimitrakopoulos,et al.  Controlled release of dexamethasone from PLGA microspheres embedded within polyacid-containing PVA hydrogels , 2005, The AAPS Journal.

[36]  Adam Heller,et al.  Redox polymer films containing enzymes. 2. Glucose oxidase containing enzyme electrodes , 1991 .

[37]  J Wang,et al.  Needle-type dual microsensor for the simultaneous monitoring of glucose and insulin. , 2001, Analytical chemistry.

[38]  N. Wisniewski,et al.  Decreased analyte transport through implanted membranes: differentiation of biofouling from tissue effects. , 2001, Journal of biomedical materials research.

[39]  C. Toumazou,et al.  Glucose sensors: a review of current and emerging technology , 2009, Diabetic medicine : a journal of the British Diabetic Association.

[40]  J. L. House,et al.  Immobilization Techniques to Avoid Enzyme Loss from Oxidase-Based Biosensors: A One-Year Study , 2007, Journal of diabetes science and technology.

[41]  A Heller,et al.  Cross-linked redox gels containing glucose oxidase for amperometric biosensor applications. , 1990, Analytical chemistry.

[42]  A Warsinke,et al.  Second generation biosensors. , 1991, Biosensors & bioelectronics.