Experimental study on cooling performance of air conditioning system with dual independent evaporative condenser
暂无分享,去创建一个
Huanwei Liu | Qiushu Zhou | Huanwei Liu | Qiushu Zhou | Yuling Liu | Peifeng Wang | Defa Wang | Peifeng Wang | Yuling Liu | Defa Wang
[1] Fu Xiao,et al. Research and application of evaporative cooling in China: A review (I) – Research , 2012 .
[2] Q. Qiu,et al. The study on the evaporation cooling efficiency and effectiveness of cooling tower of film type , 2011 .
[3] B. A. Qureshi,et al. A comprehensive design and rating study of evaporative coolers and condensers. Part II. Sensitivity analysis , 2006 .
[4] R. Martín. Numerical simulation of a semi-indirect evaporative cooler , 2009 .
[5] M. Hassan,et al. Experimental and theoretical investigation of an innovative evaporative condenser for residential refrigerator , 2009 .
[6] J. Guilpart,et al. Numerical model of sprayed air cooled condenser coupled to refrigerating system , 2007 .
[7] Detlev G. Kröger,et al. Experimental investigation into the thermal-flow performance characteristics of an evaporative cooler , 2010 .
[8] Xiaoli Hao,et al. Optimizing the pad thickness of evaporative air-cooled chiller for maximum energy saving , 2013 .
[9] Ebrahim Hajidavalloo,et al. Application of evaporative cooling on the condenser of window-air-conditioner , 2007 .
[10] A. G. Agwu Nnanna,et al. Empirical Correlation of Cooling Efficiency and Transport Phenomena of Direct Evaporative Cooler , 2012 .
[11] Pascal Boulet,et al. Improved energy performance of a refrigerating machine using water spray upstream of the condenser , 2014 .
[12] E. Hajidavalloo,et al. Performance improvement of air-cooled refrigeration system by using evaporatively cooled air condenser. , 2010 .
[13] Shahram Delfani,et al. Energy saving potential of an indirect evaporative cooler as a pre-cooling unit for mechanical cooling systems in Iran , 2010 .
[14] Syed M. Zubair,et al. A comprehensive design and rating study of evaporative coolers and condensers. Part I. Performance evaluation , 2006 .
[15] Sirichai Thepa,et al. Modeling and experimental study on the performance of an inverter air conditioner using R-410A with evaporatively cooled condenser , 2013 .
[16] Xiaosong Zhang,et al. Thermodynamic analysis of a novel energy-efficient refrigeration system subcooled by liquid desiccant dehumidification and evaporation , 2014 .
[17] Mattheos Santamouris,et al. Passive cooling dissipation techniques for buildings and other structures: The state of the art , 2013 .
[18] Syed M. Zubair,et al. A unified approach to predict evaporation losses in evaporative heat exchangers , 2011 .
[19] Andrew A. O. Tay,et al. Numerical investigation of transfer coefficients of an evaporatively-cooled condenser , 2011 .
[20] Fu Xiao,et al. Research and applications of evaporative cooling in China: A review (II)—Systems and equipment , 2012 .
[21] Reza Hosseini,et al. Numerical modeling of rigid media evaporative cooler , 2006 .
[22] Frank Bruno,et al. On-site experimental testing of a novel dew point evaporative cooler , 2011 .
[23] Xiaofeng Yang,et al. Performance enhancement of air-cooled chillers with water mist : experimental and analytical investigation , 2012 .
[24] Gaosheng Wei,et al. Scheme Design and Analysis of Variable Condition of Evaporative Condenser for Steam Condensing of Steam Feeding Water Pump for 1000MW Air-cooled Unit , 2012 .