Ion sensitive fluoroprobes such as BCECF (pH) and FURA-II (Ca2+) are frequently used indicators for determination of ion activities in single cells and subcellular compartments, e.g. by video enhanced or video intensified microscopy. Moreover, using confocal laser scanning microscopy (CLSM) with its inherent potential for noninvasive optical sectioning of cells and tissues and subsequent 3D image reconstruction, intracellular ion topographies can be monitored via pseudocolor encoded ratio imaging from pixel to pixel enabling in vivo measurements of dynamic intracellular processes. Regardless of the degree of spatial resolution, reliable qualtitative determinations essentially depend on accurate calibration of the intracellularly entrapped fluoroprobe. Calibration is either established on the basis of a whole cell or within a more or less extended subcellular compartment and the characteristics are displayed as concentration encoded pseudocolor bar within the image frame. This calibration is assumed to be valid for other cellular compartments and, in case of ion imaging, it is even thought to be valid for every single pixel of the complete pixel field. However, the assumption of a topographically invariant intracellular calibration requires a reliable behavior of the intracellularly applied indicator. This intracellular integrity of the dyes often does not seem to exist since intracellular calibration curves considerably deviate from in vitro calibration characteristics. Deviations may be due to intracellular interactions of indicator molecules with cytoplasmic macromolecules, e.g. proteins, resulting in spectral distortions and/or sensitivity deficits as demonstrated by the indicators BCECF and FURA-RED (a FURA-II analogue) or to intracellular redistribution of the indicator as exemplified by pH measurements using carboxy-SNARF-1. Consequences of these investigations as well as further potential interferences are discussed with special respect to ion imaging techniques.
[1]
L. Hamm,et al.
Use of fluorescent dye BCECF to measure intracellular pH in cortical collecting tubule.
,
1989,
The American journal of physiology.
[2]
G R Bright,et al.
Fluorescence ratio imaging microscopy.
,
1989,
Methods in cell biology.
[3]
M. Burnier,et al.
Confocal microscopy to analyze cytosolic and nuclear calcium in cultured vascular cells.
,
1994,
The American journal of physiology.
[4]
J. Carlsson,et al.
Relations between ph, oxygen partial pressure and growth in cultured cell spheroids
,
1988,
International journal of cancer.
[5]
R. Tsien,et al.
Fluorescence ratio imaging: a new window into intracellular ionic signaling
,
1986
.
[6]
Norbert Opitz,et al.
REGULATION OF INTRACELLULAR pH IN HUMAN MALIGNANT GLIOMA CELLS AS MEASURED BY CONFOCAL LASER MICROSCOPY IN MULTICELLULAR SPHEROIDS
,
1994
.
[7]
E Niggli,et al.
Ratiometric confocal Ca(2+)-measurements with visible wavelength indicators in isolated cardiac myocytes.
,
1993,
Cell calcium.
[8]
Norbert Opitz,et al.
EVALUATION PROCEDURE FOR INTRACELLULAR pH DETERMINATIONS BASED ON ION SENSITIVE FLUOROPROBES AND CONFOCAL LASER MICROSCOPY
,
1994
.
[9]
H. A. Schultens,et al.
Localization of calcium entry through calcium channels in olfactory receptor neurones using a laser scanning microscope and the calcium indicator dyes Fluo-3 and Fura-Red.
,
1994,
Cell calcium.
[10]
S. Baylor,et al.
Use of fura red as an intracellular calcium indicator in frog skeletal muscle fibers.
,
1993,
Biophysical journal.
[11]
E. Racker,et al.
Intracellular pH measurements in Ehrlich ascites tumor cells utilizing spectroscopic probes generated in situ.
,
1979,
Biochemistry.