Low Voltage Ride Through Method for Wind Turbines Based on Cooperative Control Strategy of Multiple Reactive Power Sources

With the consumption of traditional energy, renewable energy has gradually become the main force of energy production. To avoid the wind turbines tripping-off caused by the fault of power grid, the renewable energy transmission system usually needs to be equipped with a variety of reactive power compensation devices. To improve the reliability of LVRT (low voltage ride through) of wind turbines under the failure of the sending-end system, a LVRT method for wind turbines based on the cooperative control strategy of multiple reactive power sources is proposed in this paper. Firstly, this paper analyzes the reactive power output capability of the DFIG (doubly fed induction generator) and PMSG (permanent magnetic synchronous generator); and the reactive power output capability of typical reactive compensation devices i.e., SVG (static var generator) and synchronous condenser, is introduced. Secondly, based on the remaining reactive power compensation capacity and response speed of each reactive power source, the voltage regulation participation index defined as VRPI is introduced. Consequently, the cooperative control strategy of multiple reactive power sources is proposed based on the introduced index. Finally, case study of typical fault of the sending-end system integrated with wind turbines is performed, the simulation results show the effectiveness of the proposed cooperative control strategy of multiple reactive power sources.

[1]  Z. Rafiee,et al.  Enhancement of the LVRT Capability for DFIG-Based Wind Farms Based on Short-Circuit Capacity , 2022, IEEE Systems Journal.

[2]  Fengting Li,et al.  Reactive Power Control Strategy for Inhibiting Transient Overvoltage Caused by Commutation Failure , 2021, IEEE Transactions on Power Systems.

[3]  Yuzhi Wang,et al.  Impact of Synchronous Condenser on Sub/Super-Synchronous Oscillations in Wind Farms , 2021, IEEE Transactions on Power Delivery.

[4]  Heng Nian,et al.  Overvoltage Suppression Strategy for Sending AC Grid With High Penetration of Wind Power in the LCC-HVdc System Under Commutation Failure , 2021, IEEE Transactions on Power Electronics.

[5]  Zakir H. Rather,et al.  Advanced LVRT Control Scheme for Offshore Wind Power Plant , 2021, IEEE Transactions on Power Delivery.

[6]  Nahid-Al-Masood,et al.  Performance Comparison between Synchronous Condenser and Static VAR Compensator to Improve System Strength in a Wind Dominated Power Grid , 2020, 2020 11th International Conference on Electrical and Computer Engineering (ICECE).

[7]  Yi Tang,et al.  Complex Fault Source Identification Method for High-Voltage Trip-Offs of Wind Farms Based on SU-MRMR and PSO-SVM , 2020, IEEE Access.

[8]  Gang Mu,et al.  The mechanism of DFIGs grouping tripped off from power grid , 2018 .

[9]  Zhe Chen,et al.  Dynamic Reactive Power Compensation of Large-Scale Wind Integrated Power System , 2015, IEEE Transactions on Power Systems.

[10]  J. Svensson,et al.  Dynamic Performance Comparison of Synchronous Condenser and SVC , 2008, IEEE Transactions on Power Delivery.

[11]  Can Ding,et al.  LVRT control strategy for asymmetric faults of DFIG based on improved MPCC method , 2021, IEEE Access.

[12]  Tong Wang,et al.  Transient stability margin assessment of AC/DC hybrid system with commutation failure involved , 2021 .

[13]  Zixuan Zheng,et al.  LVRT Capability Improvement of DFIG-Based Wind Turbines With a Modified Bridge-Resistive-Type SFCL , 2021, IEEE Transactions on Applied Superconductivity.