Comparison of echocardiographic acoustic quantification system and radionuclide ventriculography for estimating left ventricular ejection fraction: validation in patients without regional wall motion abnormalities.

Echocardiographic automated border detection of blood-endocardium interface is made on the basis of the principle of acoustic quantification. The automated border system is capable of providing on-line left ventricular (LV) cavity area and function. Recently, ABD algorithms have been devised to estimate LV volume on line from a long-axis image, calculated by established area-length method or Simpson's formula. To test the clinical validity of this newly developed echocardiographic method, LV volumes and ejection fraction measured by real-time acoustic quantification were compared with radionuclide ejection fraction in 24 subjects on the same day. Patients were included in the study if > or = 75% of their endocardium was visualized with conventional two-dimensional echocardiography. Sixteen (66%) of 24 patients had a technically adequate conventional echocardiogram with a broad range of ventricular dimensions and systolic function. None of the study patients had regional wall motion abnormalities. Echocardiographic measurements were obtained from the LV apical four-chamber, long-axis view. Ejection fraction, determined by the acoustic quantification and by radionuclide ventriculography, showed a strong linear relation (r = 0.92, standard error of the estimate = 4.4, p < 0.05). However, acoustic quantification overestimated the radionuclide ejection fraction with rather wide limits of agreement (3.8% +/- 16.4%; bias +/- 2 SD). Thus echocardiographic automated border detection technique is a reasonably accurate method for on-line assessment of LV function.

[1]  N. Reichek,et al.  Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. , 1989, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[2]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[3]  C L Feldman,et al.  Assessment of Left Ventricular Ejection Fraction and Volumes by Real-time, Two-dimensional Echocardiography: A Comparison of Cineangiographic and Radionuclide Techniques , 1979, Circulation.

[4]  B. Brundage,et al.  Left Ventricular Volume from Paired Biplane Two‐dimensional Echocardiography , 1979, Circulation.

[5]  R J Callahan,et al.  A modified method for the in vivo labeling of red blood cells with Tc-99m: concise communication. , 1982, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  R R Miller,et al.  A New, Simplified and Accurate Method for Determining Ejection Fraction with Two‐dimensional Echocardiography , 1981, Circulation.

[7]  R M Lang,et al.  Ultrasonic backscatter system for automated on-line endocardial boundary detection: evaluation by ultrafast computed tomography. , 1993, Journal of the American College of Cardiology.

[8]  A. Weyman,et al.  Quantitative three-dimensional reconstruction of left ventricular volume with complete borders detected by acoustic quantification underestimates volume. , 1996, American Heart Journal.

[9]  J. Gorcsan,et al.  Utility and limitations of biplane transesophageal echocardiographic automated border detection for estimation of left ventricular stroke volume and cardiac output. , 1994, American heart journal.

[10]  J. G. Miller,et al.  Automated, on-line quantification of left ventricular dimensions and function by echocardiography with backscatter imaging and lateral gain compensation. , 1992, The American journal of cardiology.

[11]  A. Malhotra,et al.  Comparison of dobutamine infusion and exercise during radionuclide ventriculography in the risk stratification after acute myocardial infarction. , 1994, International journal of cardiology.

[12]  D J Hagler,et al.  Two-dimensional real-time ultrasonic imaging of the heart and great vessels. Technique, image orientation, structure identification, and validation. , 1978, Mayo Clinic proceedings.

[13]  J. G. Miller,et al.  On-line assessment of ventricular function by automatic boundary detection and ultrasonic backscatter imaging. , 1992, Journal of the American College of Cardiology.

[14]  S. M. Collins,et al.  Cyclic variation of ultrasound backscatter in normal myocardium is view dependent: clinical studies with a real-time backscatter imaging system. , 1989, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[15]  R. Engler,et al.  Measurement of Left Ventricular Ejection Fraction by Mechanical Cross-Sectional Echocardiography , 1979, Circulation.

[16]  V. Mor-Avi,et al.  Improved quantification of left ventricular function by applying signal averaging to echocardiographic acoustic quantification. , 1995, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[17]  J H Reiber,et al.  Evaluation of a semiautomatic contour detection approach in sequences of short-axis two-dimensional echocardiographic images. , 1995, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[18]  K Rezai,et al.  Quantification of left ventricular function with an automated border detection system and comparison with radionuclide ventriculography. , 1994, The American journal of cardiology.

[19]  L Goldman,et al.  Multiple gated cardiac blood pool imaging for left ventricular ejection fraction: validation of the technique and assessment of variability. , 1979, The American journal of cardiology.

[20]  J B Newell,et al.  Automated assessment of ventricular volume and function by echocardiography: validation of automated border detection. , 1994, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[21]  W J Stewart,et al.  Left ventricular volume calculation with integrated backscatter from echocardiography. , 1993, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[22]  David J. Skorton,et al.  Estimation of left ventricular cavity area with an on-line, semiautomated echocardiographic edge detection system. , 1991 .

[23]  S. M. Collins,et al.  Diagnosis of recent myocardial infarction with quantitative backscatter imaging: preliminary studies. , 1991, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[24]  J. Lazar,et al.  Comparison of left ventricular function by echocardiographic automated border detection and by radionuclide ejection fraction. , 1993, The American journal of cardiology.

[25]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[26]  L H Oliver,et al.  A second-generation computer-based edge detection algorithm for short-axis, two-dimensional echocardiographic images: accuracy and improvement in interobserver variability. , 1990, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[27]  J D Thomas,et al.  Automated echocardiographic quantification of left ventricular volumes and ejection fraction: validation in the intensive care setting. , 1995, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.