Feasibility of a novel design of high resolution parallax-free Compton enhanced PET scanner dedicated to brain research.

A novel concept for a positron emission tomography (PET) camera module is proposed, which provides full 3D reconstruction with high resolution over the total detector volume, free of parallax errors. The key components are a matrix of long scintillator crystals and hybrid photon detectors (HPDs) with matched segmentation and integrated readout electronics. The HPDs read out the two ends of the scintillator package. Both excellent spatial (x, y, z) and energy resolution are obtained. The concept allows enhancing the detection efficiency by reconstructing a significant fraction of events which underwent Compton scattering in the crystals. The proof of concept will first be demonstrated with yttrium orthoaluminate perovskite (YAP):Ce crystals, but the final design will rely on other scintillators more adequate for PET applications (e.g. LSO:Ce or LaBr3:Ce). A promising application of the proposed camera module, which is currently under development, is a high resolution 3D brain PET camera with an axial field-of-view of approximately 15 cm dedicated to brain research. The design philosophy and performance predictions based on analytical calculations and Monte Carlo simulations are presented. Image correction and reconstruction tools required to operate this transmissionless device in a research environment are also discussed. Better or similar performance parameters were obtained compared to other known designs at lower fabrication cost. The axial geometrical concept also seems to be promising for applications such as positron emission mammography.

[1]  Habib Zaidi,et al.  Novel design of a parallax free Compton enhanced PET scanner , 2004 .

[2]  Habib Zaidi,et al.  Correction for image degrading factors is essential for accurate quantification of brain function using PET. For the proposition. , 2004, Medical physics.

[3]  M. Daube-Witherspoon,et al.  Performance of a brain PET camera based on anger-logic gadolinium oxyorthosilicate detectors. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  H. Zaidi,et al.  Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography. , 2003, Medical physics.

[5]  P. Weilhammer,et al.  The Pad HPD: A highly segmented hybrid photodiode , 2003 .

[6]  G. Muehllehner,et al.  Investigation of lanthanum scintillators for 3-D PET , 2002 .

[7]  William W. Moses,et al.  Current trends in scintillator detectors and materials , 2002 .

[8]  N. Sato,et al.  A new high resolution PET scanner dedicated to brain research , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[9]  J. Karp,et al.  Performance measurements for the GSO-based brain PET camera (G-PET) , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[10]  Michael A. King,et al.  Resolution recovery for list-mode reconstruction in SPECT. , 2001 .

[11]  W. Heiss,et al.  The ECAT HRRT: performance and first clinical application of the new high resolution research tomograph , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[12]  P. Weilhammer Silicon-based HPD development: sensors and front ends , 2000 .

[13]  Richard M. Leahy,et al.  Resolution and noise properties of MAP reconstruction for fully 3-D PET , 2000, IEEE Transactions on Medical Imaging.

[14]  M. Phelps,et al.  PET: the merging of biology and imaging into molecular imaging. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  C. Joram Large area hybrid photodiodes , 1999 .

[16]  H. Zaidi,et al.  An object-oriented Monte Carlo simulator for 3D cylindrical positron tomographs. , 1999, Computer methods and programs in biomedicine.

[17]  Simon R. Cherry,et al.  The Changing Design of Positron Imaging Systems. , 1998, Clinical positron imaging : official journal of the Institute for Clinical P.E.T.

[18]  K. Wienhard,et al.  Performance results of a new DOI detector block for a high resolution PET-LSO research tomograph HRRT , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[19]  H. Zaidi,et al.  Attenuation compensation in cerebral 3D PET: effect of the attenuation map on absolute and relative quantitation , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[20]  A. Dell'Acqua,et al.  Geant4—a simulation toolkit , 2003 .

[21]  C. V. van Eijk Inorganic scintillators in medical imaging. , 2002, Physics in medicine and biology.

[22]  P. Green Bayesian reconstructions from emission tomography data using a modified EM algorithm. , 1990, IEEE transactions on medical imaging.