IntroductionThe aim of this study was to evaluate the feasibility and accuracy of commercially available software directly implemented on the ultrasound scanner for automated measurement of the intima-media thickness (IMT) of the common carotid artery on source images.Materials and methodsMeasurements were performed on a GE Vivid 3 ultrasound scanner. First, inter- and intraobserver correlations were assessed for the automated and the manual measurements. Second, the correlation between automated and manual measurements was assessed in 199 asymptomatic patients with a mean age of 30 years (range 20–41 years).ResultsThe measurement was feasible in all patients and a standard configuration with optimum quality was determined. The inter- and intraobserver correlations obtained using the automated software were excellent and slightly inferior to the manual measurements. The correlation of the automated and manual measurements was significant (r = 0.86; P < 0.01) and the mean difference between both measurements was low (0.023 ± 0.034 mm).ConclusionsThe software allowed an efficient and quick measurement by providing at the same time comparable results to the manual measurement and a better inter- and intraobserver variability.

[1]  G. Berglund,et al.  Progression of atherosclerosis in middle‐aged men:  effects of multifactorial intervention , 1996, Journal of internal medicine.

[2]  C.P. Loizou,et al.  Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid artery , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  C.S. Pattichis,et al.  An Integrated System for the Segmentation of Atherosclerotic Carotid Plaque , 2007, IEEE Transactions on Information Technology in Biomedicine.

[4]  Arno W. Hoes,et al.  Common carotid intima-media thickness and risk of stroke and myocardial infarction: the Rotterdam Study. , 1997, Circulation.

[5]  C Schmidt,et al.  How can the variability in ultrasound measurement of intima-media thickness be reduced? Studies of interobserver variability in carotid and femoral arteries. , 1999, Clinical physiology.

[6]  Liexiang Fan,et al.  A semiautomated ultrasound border detection program that facilitates clinical measurement of ultrasound carotid intima-media thickness. , 2005, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[7]  T. Elatrozy,et al.  The effect of B-mode ultrasonic image standardisation on the echodensity of symptomatic and asymptomatic carotid bifurcation plaques. , 1998, International angiology : a journal of the International Union of Angiology.

[8]  A. Zwinderman,et al.  Association between increased arterial-wall thickness and impairment in ABCA1-driven cholesterol efflux: an observational study , 2002, The Lancet.

[9]  E. Vicaut,et al.  Mannheim Carotid Intima-Media Thickness Consensus (2004–2006) , 2006, Cerebrovascular Diseases.

[10]  P M Rautaharju,et al.  Arterial wall thickness is associated with prevalent cardiovascular disease in middle-aged adults. The Atherosclerosis Risk in Communities (ARIC) Study. , 1995, Stroke.

[11]  D. Altman,et al.  Measuring agreement in method comparison studies , 1999, Statistical methods in medical research.

[12]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[13]  Christos P. Loizou,et al.  Snakes based segmentation of the common carotid artery intima media , 2007, Medical & Biological Engineering & Computing.

[14]  R H Selzer,et al.  The Role of Carotid Arterial Intima-Media Thickness in Predicting Clinical Coronary Events , 1998, Annals of Internal Medicine.

[15]  O. Wiklund,et al.  On quantifying plaque size and intima-media thickness in carotid and femoral arteries. Comments on results from a prospective ultrasound study in patients with familial hypercholesterolemia. , 1996, Arteriosclerosis, thrombosis, and vascular biology.

[16]  Oğuz Dicle,et al.  Automated measurement of intima-media thickness of carotid arteries in ultrasonography by computer software. , 2005, Diagnostic and interventional radiology.

[17]  J. Salonen,et al.  Ultrasound B-mode imaging in observational studies of atherosclerotic progression. , 1993, Circulation.

[18]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[19]  E. Vicaut,et al.  Mannheim Intima-Media Thickness Consensus , 2004, Cerebrovascular Diseases.

[20]  T Gustavsson,et al.  Ultrasound measurement of wall thickness in the carotid artery: fundamental principles and description of a computerized analysing system. , 1991, Clinical physiology.

[21]  M L Bots,et al.  Isolated systolic hypertension and vessel wall thickness of the carotid artery. The Rotterdam Elderly Study. , 1993, Arteriosclerosis and thrombosis : a journal of vascular biology.

[22]  R H Selzer,et al.  Improved common carotid elasticity and intima-media thickness measurements from computer analysis of sequential ultrasound frames. , 2001, Atherosclerosis.

[23]  A. Algra,et al.  Reproducibility of in vivo carotid intima-media thickness measurements: a review. , 1997, Stroke.

[24]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[25]  IngerWendelhag,et al.  A New Automated Computerized Analyzing System Simplifies Readings and Reduces the Variability in Ultrasound Measurement of Intima-Media Thickness , 1997 .

[26]  A. Folsom,et al.  Association of coronary heart disease incidence with carotid arterial wall thickness and major risk factors: the Atherosclerosis Risk in Communities (ARIC) Study, 1987-1993. , 1997, American journal of epidemiology.