An Unobtrusive Wearable Device for Ambulatory Monitoring of Pulse Transit Time to Estimate Central Blood Pressure

There is a clinical need for improved ambulatory, frequent and unobtrusive monitoring of blood pressure and cardiac parameters like systolic time intervals. Truly unobtrusive wearable devices combining impedance cardiography with other sensors may be one possible solution. The IsenseU-BP+ device presented in this article measures single channel ECG, impedance cardiography and photo plethysmography at the chest. The device also measures activity and posture, as well as skin temperature. In this study, we report on the possibility to use these signals to measure pulse transit time for estimating blood pressure changes. Six subjects has been tested. Four of them showed good correlation between PTT and mean arterial pressure while two of the subjects had too low signal to noise ratio in the photoplethysmography signal for good estimation of PTT. Thus these results show that the quality of the raw data is promising for calculating a pulse transit time that shows good coherence with mean arterial pressure.

[1]  E. Nieuwlaar European Society of Hypertension International Protocol revision 2010 forthe validation of blood pressure measuring devices in adults: Erratum: , 2010 .

[2]  Claudio Sartori,et al.  Noninvasive and Nonocclusive Blood Pressure Estimation Via a Chest Sensor , 2013, IEEE Transactions on Biomedical Engineering.

[3]  L. Brush,et al.  McDonaldʼs Blood Flow in Arteries , 1991 .

[4]  Yutaka Imai,et al.  European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults , 2010, Blood pressure monitoring.

[5]  Mehmet Rasit Yuce,et al.  A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time , 2015, Physiological measurement.

[6]  X. Aubert,et al.  Cuffless Estimation of Systolic Blood Pressure for Short Effort Bicycle Tests: The Prominent Role of the Pre-Ejection Period , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  Olivier Chételat,et al.  Chest Pulse-Wave Velocity: A Novel Approach to Assess Arterial Stiffness , 2011, IEEE Transactions on Biomedical Engineering.

[8]  E. O’Brien,et al.  Prognostic significance of visit-to-visit variability, maximum systolic blood pressure, and episodic hypertension , 2010, The Lancet.

[9]  Jeroen J. Bax,et al.  2007 ESH-ESC Guidelines for the management of arterial hypertension: the task force for the management of arterial hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC). , 2007, Blood pressure.

[10]  Panayiotis A. Kyriacou,et al.  Investigation of Pulse Transit Times utilizing multisite reflectance photoplethysmography under conditions of artificially induced peripheral vasoconstriction , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  Alexander Hapfelmeier,et al.  Continuous noninvasive arterial pressure measurement using the volume clamp method: an evaluation of the CNAP device in intensive care unit patients , 2015, Journal of Clinical Monitoring and Computing.

[12]  J. Muehlsteff,et al.  Continuous cuff-less blood pressure monitoring based on the pulse arrival time approach: The impact of posture , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  René van Lien,et al.  Estimated preejection period (PEP) based on the detection of the R-wave and dZ/dt-min peaks does not adequately reflect the actual PEP across a wide range of laboratory and ambulatory conditions. , 2013, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[14]  X. Aubert,et al.  Is pulse transit time a good indicator of blood pressure changes during short physical exercise in a young population? , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[15]  M. Steinfath,et al.  Comparison of a continuous noninvasive arterial pressure device with invasive measurements in cardiovascular postsurgical intensive care patients: A prospective observational study , 2015, European journal of anaesthesiology.

[16]  N. Hwang,et al.  Measurement of cardiac output using Physio Flow with different positions of electrode placement. , 2006, Singapore medical journal.

[17]  Robert P Patterson,et al.  Impedance cardiography: What is the source of the signal? , 2010 .