Two-Stage Revision for Infected Total Knee Arthroplasty: Based on Autoclaving the Recycled Femoral Component and Intraoperative Molding Using Antibiotic-Impregnated Cement on the Tibial Side

Background The purpose of this study was to determine the degree of infection control and postoperative function for new articulating metal-on-cement spacer. Methods A retrospective study of 19 patients (20 cases), who underwent a two-stage revision arthroplasty using mobile cement prosthesis, were followed for a minimum of 2 years. This series consisted of 16 women and 3 men, having an overall mean age of 71 years. During the first stage of revision, the femoral implant and all the adherent cement was removed, after which it was autoclaved before replacement. The tibial component was removed and a doughy state, antibiotic-impregnated cement was inserted on the tibial side. To achieve joint congruency, intraoperative molding was performed by flexing and extending the knee joint. Each patient was evaluated clinically and radiologically. The clinical assessments included range of motion, and the patients were scored as per the Hospital for Special Surgery (HSS) and Knee Society (KS) criteria. Results The mean range of knee joint motion was 70° prior to the first stage operation and 72° prior to the second stage revision arthroplasty; following revision arthroplasty, it was 113° at the final follow-up. The mean HSS score and KS knee and function scores were 86, 82, and 54, respectively, at the final follow-up. The success rate in terms of infection eradication was 95% (19/20 knees). No patient experienced soft tissue contracture requiring a quadriceps snip. Conclusions This novel technique provides excellent radiological and clinical outcomes. It offers a high surface area of antibiotic-impregnated cement, a good range of motion between first and second stage revision surgery for the treatment of chronic infection after total knee arthroplasty, and is of a reasonable cost.

[1]  H. Kyung,et al.  Incidence of Venous Thromboembolism Using 64 Channel Multidetector Row Computed Tomography-Indirect Venography and Anti-Coagulation Therapy after Total Knee Arthroplasty in Korea , 2012, Knee surgery & related research.

[2]  L. Drago,et al.  Two-stage revision of septic knee prosthesis with articulating knee spacers yields better infection eradication rate than one-stage or two-stage revision with static spacers , 2012, Knee Surgery, Sports Traumatology, Arthroscopy.

[3]  E. Cheng,et al.  Is There a Preferred Articulating Spacer Technique for Infected Knee Arthroplasty?: A Preliminary Study , 2012, Clinical orthopaedics and related research.

[4]  B. Masri,et al.  Durable Infection Control and Function With the PROSTALAC Spacer in Two-stage Revision for Infected Knee Arthroplasty , 2011, Clinical orthopaedics and related research.

[5]  A. Lombardi,et al.  Intraoperative Molds to Create an Articulating Spacer for the Infected Knee Arthroplasty , 2011, Clinical orthopaedics and related research.

[6]  김선홍,et al.  Original Article : Two-Stage Reimplantation in Infected Total Knee Arthroplasty (A Method of Reinsertion of the Autoclaved Femoral Component and a Polyethylene Liner) , 2010 .

[7]  A. Hanssen,et al.  Prior Use of Antimicrobial Therapy is a Risk Factor for Culture-negative Prosthetic Joint Infection , 2010, Clinical orthopaedics and related research.

[8]  C. Oh,et al.  An Articulating Versus Non-articulating Spacer for 2-Stage Reimplantation Patients Who Undergo in Infected Total Knee Arthroplasty , 2009 .

[9]  K. Garvin,et al.  Infected total knee arthroplasty: diagnosis and treatment. , 2008, Instructional course lectures.

[10]  S. Odum,et al.  Functional advantage of articulating versus static spacers in 2-stage revision for total knee arthroplasty infection. , 2007, The Journal of arthroplasty.

[11]  K. Chiu,et al.  Antibiotic-loaded cement articulating spacer for 2-stage reimplantation in infected total knee arthroplasty: a simple and economic method. , 2007, The Journal of arthroplasty.

[12]  A. Lombardi,et al.  Articulating antibiotic spacers: the standard of care for an infected total knee arthroplasty. , 2007, Orthopedics.

[13]  Khaled J Saleh,et al.  Antibiotic-impregnated cement spacers for the treatment of infection associated with total hip or knee arthroplasty. , 2007, The Journal of bone and joint surgery. American volume.

[14]  Hsuan-Ti Huang,et al.  The results of articulating spacer technique for infected total knee arthroplasty. , 2006, The Journal of arthroplasty.

[15]  A. Amin,et al.  Five-year results of the Sigma total knee arthroplasty. , 2006, The Knee.

[16]  C. Ha A Technique for Intraoperative Construction of Antibiotic Spacers , 2006, Clinical orthopaedics and related research.

[17]  Y. Konttinen,et al.  Spacer prostheses in two-stage revision of infected knee arthroplasty , 2006, International Orthopaedics.

[18]  S. Hofmann,et al.  Treatment of deep infection of total knee arthroplasty using a two-stage procedure. , 2006, Operative Orthopadie und Traumatologie.

[19]  S. Hofmann,et al.  Zweizeitiger Prothesenwechsel bei infizierter Knieendoprothese , 2006, Operative Orthopädie und Traumatologie.

[20]  A. Hanssen,et al.  Management of infection at the site of a total knee arthroplasty. , 2005, The Journal of bone and joint surgery. American volume.

[21]  A. Hofmann,et al.  Treatment of Infected Total Knee Arthroplasty Using an Articulating Spacer: 2- to 12-Year Experience , 2005, Clinical orthopaedics and related research.

[22]  R. Uhl,et al.  Antibiotic-loaded articulating cement spacer in the 2-stage exchange of infected total knee arthroplasty. , 2004, The Journal of arthroplasty.

[23]  R. Emerson,et al.  Comparison of a Static with a Mobile Spacer in Total Knee Infection , 2002, Clinical orthopaedics and related research.

[24]  M. Ritter,et al.  Long-Term Followup of Nonmodular Total Knee Replacements , 2002, Clinical orthopaedics and related research.

[25]  S. Odum,et al.  Articulating Versus Static Spacers in Revision Total Knee Arthroplasty for Sepsis , 2000, Clinical orthopaedics and related research.

[26]  L. Costa,et al.  In vivo UHMWPE biodegradation of retrieved prosthesis. , 1998, Biomaterials.

[27]  H. Kyung,et al.  Experimental Study of Release of the Gentamicin from PMMA Beads : in vivo study , 1997 .

[28]  W H Harris,et al.  Gamma sterilization of UHMWPE articular implants: an analysis of the oxidation problem. Ultra High Molecular Weight Poly Ethylene. , 1996, Biomaterials.

[29]  A. Hofmann,et al.  Treatment of Infected Total Knee Arthroplasty Using an Articulating Spacer , 1995, Clinical orthopaedics and related research.

[30]  J. Rand Evaluation and management of infected total knee arthroplasty. , 1994, Seminars in arthroplasty.

[31]  K. Knutson,et al.  The infected knee arthroplasty. A 6-year follow-up of 357 cases. , 1991, Acta orthopaedica Scandinavica.