Fabrication and performance evaluation of highly sensitive hybrid sol-gel-derived oxygen sensor films based on a fluorinated precursor.

This paper describes the fabrication and performance of a range of highly sensitive luminescence-based oxygen sensor films based on the fluorinated sol-gel precursor 3,3,3-trifluoropropyltrimethoxysilane (TFP-TMOS). The oxygen-sensitive ruthenium complex [Ruthenium(II)-tris(4,7-diphenyl-1,10-phenanthroline)] dichloride, [Ru(dpp)(3)](2+) was entrapped in a wide range of ORMOSILs (organically modified silicates) matrices composed of alkyl and TFP-TMOS sol-gel precursors in different relative ratios. The influence of TFP-TMOS on sensor sensitivity, humidity-sensitivity and long-term stability was investigated and performance was compared to that of similar but non-fluorinated films. The optimum limit of detection was found to be 0.002% of oxygen for the propyltriethoxysilane (PTEOS)/TFP-TMOS-derived film compared to 0.09% for PTEOS-derived films reported previously. Photobleaching of the luminescent complex in fluorinated and non-fluorinated matrices was also investigated. It was established that photobleaching was reduced but not eliminated in fluorinated films. All films produced in this study exhibit very good reproducibility, reversibility, enhanced sensitivity, humidity-insensitivity and long-term stability.

[1]  Dmitri B. Papkovsky,et al.  Study of migration of active components of phosphorescent oxygen sensors for food packaging applications , 2005 .

[2]  Ichiro Okura,et al.  Green luminescent iridium(III) complex immobilized in fluoropolymer film as optical oxygen-sensing material , 2001 .

[3]  B. MacCraith,et al.  Breath-by-breath measurement of oxygen using a compact optical sensor. , 2008, Journal of biomedical optics.

[4]  Raymond T. Bailey,et al.  A composite thin film optical sensor for dissolved oxygen in contaminated aqueous environments , 2005 .

[5]  Kuei-Chien Chang,et al.  Preparation of super‐hydrophobic film with fluorinated‐copolymer , 2007 .

[6]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[7]  F. Bright,et al.  Using sol-gel-based platforms for chemical sensors , 1997 .

[8]  Hartmann Photochemically induced energy-transfer effects on the decay times of ruthenium complexes in polymers , 2000, Analytical chemistry.

[9]  J. Demas,et al.  Oxygen Sensors Based on Luminescence Quenching: Interactions of Tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) Chloride and Pyrene with Polymer Supports , 1997 .

[10]  Xudong Ge,et al.  Validation of an optical sensor-based high-throughput bioreactor system for mammalian cell culture. , 2006, Journal of biotechnology.

[11]  P. Hartmann,et al.  Effects of polymer matrices on calibration functions of luminescent oxygen sensors based on porphyrin ketone complexes. , 1996, Analytical chemistry.

[12]  Marc J.P. Leiner,et al.  Luminescence chemical sensors for biomedical applications: scope and limitations , 1991 .

[13]  B. MacCraith,et al.  Tailoring of sol-gel films for optical sensing of oxygen in gas and aqueous phase. , 1998, Analytical chemistry.

[14]  Ingo Klimant,et al.  Oxygen-Sensitive Luminescent Materials Based on Silicone-Soluble Ruthenium Diimine Complexes , 1995 .

[15]  B. Schneider,et al.  A new method for continuous measurements of O2 in surface water in combination with pCO2 measurements: Implications for gas phase equilibration , 2007 .

[16]  Paul Hartmann,et al.  Photobleaching of a ruthenium complex in polymers used for oxygen optodes and its inhibition by singlet oxygen quenchers , 1998 .

[17]  R. Gillanders,et al.  Thin film dissolved oxygen sensor based on platinum octaethylporphyrin encapsulated in an elastic fluorinated polymer , 2004 .

[18]  S. Lehrer Solute perturbation of protein fluorescence. The quenching of the tryptophyl fluorescence of model compounds and of lysozyme by iodide ion. , 1971, Biochemistry.

[19]  Alfredo Sanz-Medel,et al.  Sol–gel immobilized room-temperature phosphorescent metal-chelate as luminescent oxygen sensing material , 1998 .

[20]  Benjamin A. DeGraff,et al.  Luminescence quenching mechanism for microheterogeneous systems , 1991 .

[21]  J. Demas,et al.  Oxygen Sensors Based on a Quenching of Tris-(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) in Fluorinated Polymers , 2000, Journal of Fluorescence.

[22]  B. MacCraith,et al.  Optical Sol-Gel-Based Dissolved Oxygen Sensor: Progress Towards a Commercial Instrument , 1998 .

[23]  Colette McDonagh,et al.  Optimization of Ormosil Films for Optical Sensor Applications , 1998 .

[24]  B. MacCraith,et al.  Development of a compact optical sensor for real-time, breath-by-breath detection of oxygen. , 2008, Journal of breath research.

[25]  A. Titus,et al.  O2-Responsive Chemical Sensors Based on Hybrid Xerogels That Contain Fluorinated Precursors , 2006, Applied spectroscopy.

[26]  James N. Demas,et al.  Determination of oxygen concentrations by luminescence quenching of a polymer-immobilized transition-metal complex , 1987 .

[27]  M. Collinson Analytical applications of organically modified silicates , 1998 .

[28]  Kunio Kimura,et al.  Novel optical oxygen sensing material: metalloporphyrin dispersed in fluorinated poly(aryl ether ketone) films , 2002 .

[29]  A. Heimann,et al.  Brain oxygen monitoring: in-vitro accuracy, long-term drift and response-time of Licox- and Neurotrend sensors , 2005, Acta Neurochirurgica.

[30]  Colette McDonagh,et al.  Novel hybrid optical sensor materials for in-breath O(2) analysis. , 2008, The Analyst.

[31]  I. Gryczynski,et al.  Decreasing photobleaching by silver island films: application to muscle. , 2007, Analytical biochemistry.

[32]  G. A. Crosby,et al.  Spectroscopic characterization of complexes of ruthenium(II) and iridium(III) with 4,4'-diphenyl-2,2'-bipyridine and 4,7-diphenyl-1,10-phenanthroline , 1971 .

[33]  Christian Krause,et al.  Composite Luminescent Material for Dual Sensing of Oxygen and Temperature , 2006 .

[34]  M. Collinson Recent trends in analytical applications of organically modified silicate materials , 2002 .

[35]  Frank V Bright,et al.  Sol-gel-derived sensor materials that yield linear calibration plots, high sensitivity, and long-term stability. , 2003, Analytical chemistry.

[36]  Rosaria Ciriminna,et al.  High-performance quenchometric oxygen sensors based on fluorinated xerogels doped with [Ru(dpp)3]2+. , 2005, Analytical chemistry.

[37]  O. Wolfbeis Fiber-optic chemical sensors and biosensors. , 2000, Analytical chemistry.

[38]  J. Demas,et al.  Oxygen sensors based on luminescence quenching: interactions of metal complexes with the polymer supports. , 1994, Analytical chemistry.

[39]  Colette McDonagh,et al.  Phase fluorometric dissolved oxygen sensor , 2001 .

[40]  Colette McDonagh,et al.  Plasmonic enhancement of fluorescence for sensor applications , 2005 .

[41]  Chris W. Brown,et al.  Sol-gel glass as a matrix for chemical and biochemical sensing , 1997 .

[42]  Ingo Klimant,et al.  Fast Response Oxygen Micro-Optodes Based on Novel Soluble Ormosil Glasses , 1999 .

[43]  Benjamin A. DeGraff,et al.  Applications of Luminescent Transition Platinum Group Metal Complexes to Sensor Technology and Molecular Probes , 2001 .

[44]  P. Douglas,et al.  Effect of humidity on the response characteristics of luminescent PtOEP thin film optical oxygen sensors , 2002 .

[45]  Andrew Mills,et al.  Response characteristics of optical sensors for oxygen: a model based on a distribution in τoand kq , 1999 .

[46]  A. Mills Oxygen indicators and intelligent inks for packaging food. , 2005, Chemical Society reviews.