Amperometric acetylthiocholine sensor based on acetylcholinesterase immobilized on nanostructured polymer membrane containing gold nanoparticles

Abstract Poly(acrylonitrile-methylmethacrylate-sodium vinylsulfonate) membranes were chemically modified and loaded with gold nanoparticles. Acetylcholinesterase was immobilized on the prepared membranes in accordance with two distinctive procedures, the first of which involved immobilization of the enzyme by convection, and the other by diffusion. The prepared enzyme carriers were used for the construction of amperometric biosensors for detection of acetylthiocholine. Two sets of experiments were carried out. The first set was designed so that to evaluate the effects of the gold nanoparticle deployment and the immobilization procedures over the biosensor effectiveness. The other set of experiments was conducted in order to determine the influence of the individual components of the enzyme mixture, containing gold nanoparticles, acetylcholinesterase, bovine serum albumin and glutaraldehyde, over the current output of the constructed acetylthiocholine biosensors. The optimum composition of the mixture was determined to be as follows: enzyme, 0.1 U ml −1 ; gold nanoparticles, 0.50 ml (per 1 ml enzyme mixture); albumin, 0.5% and glutaraldehyde, 0.7%. On the basis of the experimental results, the most efficient enzyme membrane was selected and used for the preparation of an acetylthiocholine biosensor. Its basic amperometric characteristics were investigated. A calibration plot was obtained for ATCh concentration ranging from 10 to 400 μM. A linear interval was detected along the calibration curve from 10 to 170 μM. The sensitivity of the constructed biosensor was calculated to be 0.066 μA μM −1  cm −2 . The correlation coefficient for this concentration range was 0.996. The detection limit with regard to ATCh was calculated to be 1.80 μM. The potential application of the biosensor for detection and quantification of organophosphate pesticides was investigated as well. It was tested against sample solutions of Paraoxon. The biosensor detection limit for Paraoxon was determined, 7.39 × 10 −11  g l −1 , as well as the concentration interval (10 −10 to 10 −7  g l −1 ) within which the biosensor response was linearly dependant on Paraoxon concentration. Finally the storage stability of the enzyme carrier was traced for a period of 50 days. After storage for 20 days the sensor retained 75% of its initial current response and after 30 days −25%.

[1]  Dan Du,et al.  An amperometric acetylthiocholine sensor based on immobilization of acetylcholinesterase on a multiwall carbon nanotube–cross-linked chitosan composite , 2007, Analytical and bioanalytical chemistry.

[2]  Changqing Sun,et al.  Gold nanoparticles-mesoporous silica composite used as an enzyme immobilization matrix for amperometric glucose biosensor construction , 2007 .

[3]  Song Zhang,et al.  A mediator-free screen-printed amperometric biosensor for screening of organophosphorus pesticides with flow-injection analysis (FIA) system. , 2006, Talanta.

[4]  Dan Du,et al.  Amperometric detection of triazophos pesticide using acetylcholinesterase biosensor based on multiwall carbon nanotube–chitosan matrix , 2007 .

[5]  P. Millner,et al.  Acetylcholinesterase-based biosensor electrodes for organophosphate pesticide detection. I. Modification of carbon surface for immobilization of acetylcholinesterase. , 2004, Biosensors & bioelectronics.

[6]  Francis Moussy,et al.  A long-term flexible minimally-invasive implantable glucose biosensor based on an epoxy-enhanced polyurethane membrane. , 2006, Biosensors & bioelectronics.

[7]  Masatoshi Hashimoto,et al.  Dependence of the response of an amperometric biosensor formed in a micro flow channel on structural and conditional parameters. , 2006, Biosensors & bioelectronics.

[8]  Y. Chai,et al.  A label-free amperometric immunosenor based on multi-layer assembly of polymerized o-phenylenediamine and gold nanoparticles for determination of Japanese B encephalitis vaccine , 2005 .

[9]  Jean-Louis Marty,et al.  Versatile method of cholinesterase immobilisation via affinity bonds using Concanavalin A applied to the construction of a screen-printed biosensor. , 2004, Biosensors & bioelectronics.

[10]  R. Fussell,et al.  Comparison of ultra-performance liquid chromatography and high-performance liquid chromatography for the determination of priority pesticides in baby foods by tandem quadrupole mass spectrometry. , 2006, Journal of chromatography. A.

[11]  Marek Trojanowicz,et al.  Determination of Pesticides Using Electrochemical Enzymatic Biosensors , 2002 .

[12]  A. Piccolo,et al.  Optical microsensors for pesticides identification based on porous silicon technology. , 2005, Biosensors & bioelectronics.

[13]  Dan Du,et al.  Immobilization of acetylcholinesterase on gold nanoparticles embedded in sol-gel film for amperometric detection of organophosphorous insecticide. , 2007, Biosensors & bioelectronics.

[14]  Itamar Willner,et al.  "Plugging into Enzymes": Nanowiring of Redox Enzymes by a Gold Nanoparticle , 2003, Science.

[15]  Vasif Hasirci,et al.  Determination of binary pesticide mixtures by an acetylcholinesterase-choline oxidase biosensor. , 2004, Biosensors & bioelectronics.

[16]  Joseph Wang,et al.  Disposable Carbon Nanotube Modified Screen‐Printed Biosensor for Amperometric Detection of Organophosphorus Pesticides and Nerve Agents , 2004 .

[17]  P. He,et al.  Colloid Au-enhanced DNA immobilization for the electrochemical detection of sequence-specific DNA , 2001 .

[18]  Jean-Louis Marty,et al.  Twenty years research in cholinesterase biosensors: from basic research to practical applications. , 2006, Biomolecular engineering.

[19]  N. Chaniotakis,et al.  Lowering the detection limit of the acetylcholinesterase biosensor using a nanoporous carbon matrix , 2005 .

[20]  R. Pilloton,et al.  Direct mediatorless electron transport between the monolayer of photosystem II and poly(mercapto-p-benzoquinone) modified gold electrode--new design of biosensor for herbicide detection. , 2005, Biosensors & bioelectronics.

[21]  Ilaria Palchetti,et al.  Evaluation of pesticide-induced acetylcholinesterase inhibition by means of disposable carbon-modified electrochemical biosensors , 2007 .

[22]  Huangxian Ju,et al.  Binding of acetylcholinesterase to multiwall carbon nanotube-cross-linked chitosan composite for flow-injection amperometric detection of an organophosphorous insecticide. , 2006, Chemistry.

[23]  Charlotte Carlsson,et al.  Amperometric screen-printed biosensor arrays with co-immobilised oxidoreductases and cholinesterases , 2005 .

[24]  Huangxian Ju,et al.  Hydrogen peroxide sensor based on horseradish peroxidase-labeled Au colloids immobilized on gold electrode surface by cysteamine monolayer , 1999 .

[25]  Robert C. Haddon,et al.  A Disposable Biosensor for Organophosphorus Nerve Agents Based on Carbon Nanotubes Modified Thick Film Strip Electrode , 2005 .

[26]  Shang-da Huang,et al.  Determination of ethoprop, diazinon, disulfoton and fenthion using dynamic hollow fiber-protected liquid-phase microextraction coupled with gas chromatography-mass spectrometry. , 2006, Talanta.

[27]  Till T Bachmann,et al.  Design of acetylcholinesterases for biosensor applications. , 2003, Biosensors & bioelectronics.

[28]  Huangxian Ju,et al.  Application of Colloidal Gold in Protein Immobilization, Electron Transfer, and Biosensing , 2003 .

[29]  A. L. Crumbliss,et al.  Colloidal gold as a biocompatible immobilization matrix suitable for the fabrication of enzyme electrodes by electrodeposition , 1992, Biotechnology and bioengineering.

[30]  S. Mohan,et al.  Development of acetylcholinesterase silica sol-gel immobilized biosensor--an application towards oxydemeton methyl detection. , 2004, Biosensors & bioelectronics.

[31]  Ying Zhang,et al.  A reagentless amperometric immunosensor based on gold nanoparticles/thionine/Nafion-membrane-modified gold electrode for determination of α-1-fetoprotein , 2005 .

[32]  T. Godjevargova,et al.  Immobilization of acetylcholinesterase on nanostructure polyacrylonitrile membranes. , 2009, International journal of biological macromolecules.

[33]  Michael V. Pishko,et al.  Microfabricated protein-containing poly(ethylene glycol) hydrogel arrays for biosensing , 2004 .