Behavior of metallic fuel in treat transient overpower tests
暂无分享,去创建一个
Results and analyses are reported for TREAT in-pile transient overpower tests of margin to cladding failure and pre-failure axial expansion of metallic fuel. In all cases the power rise was exponential on an 8 s period until either incipient or actual cladding failure was achieved. Test fuel included EBR-II driver fuel and ternary alloy, the reference fuel of the Intergral Fast Reactor concept. Test pin burnup spanned the widest range available. The nature of the observed cladding failure and resultant fuel dispersals is described. Simple models are presented which describe observed cladding failures and pre-failure axial expansions yet are general enough to apply to all metal fuel types.