Single shot trajectory design for region‐specific imaging using linear and nonlinear magnetic encoding fields

It has recently been demonstrated that nonlinear encoding fields result in a spatially varying resolution. This work develops an automated procedure to design single‐shot trajectories that create a local resolution improvement in a region of interest. The technique is based on the design of optimized local k‐space trajectories and can be applied to arbitrary hardware configurations that employ any number of linear and nonlinear encoding fields. The trajectories designed in this work are tested with the currently available hardware setup consisting of three standard linear gradients and two quadrupolar encoding fields generated from a custom‐built gradient insert. A field camera is used to measure the actual encoding trajectories up to third‐order terms, enabling accurate reconstructions of these demanding single‐shot trajectories, although the eddy current and concomitant field terms of the gradient insert have not been completely characterized. The local resolution improvement is demonstrated in phantom and in vivo experiments. Magn Reson Med 70:684–696, 2013. © 2012 Wiley Periodicals, Inc.

[1]  Mark R. Morelande,et al.  Performance Analysis for Magnetic Resonance Imaging With Nonlinear Encoding Fields , 2012, IEEE Transactions on Medical Imaging.

[2]  J. Hennig,et al.  First In-vivo Results with a PatLoc Gradient Insert Coil for Human Head Imaging , 2010 .

[3]  Gerhard Wachutka,et al.  Robust, susceptibility-matched NMR probes for compensation of magnetic field imperfections in magnetic resonance imaging (MRI) , 2008 .

[4]  Douglas C. Noll Rapid MR image acquisition in the presence of background gradients , 2002, Proceedings IEEE International Symposium on Biomedical Imaging.

[5]  G. Mckinnon,et al.  Ultra-high-speed MR imaging , 2004, European Radiology.

[6]  K. P. Pruessmann,et al.  A third-order field camera with microsecond resolution for MR system diagnostics , 2008 .

[7]  Gigi Galiana,et al.  O‐space imaging: Highly efficient parallel imaging using second‐order nonlinear fields as encoding gradients with no phase encoding , 2010, Magnetic resonance in medicine.

[8]  Bruce J Balcom,et al.  Pure phase encode magnetic field gradient monitor. , 2009, Journal of magnetic resonance.

[9]  J M Hutchison,et al.  Concomitant magnetic field gradients and their effects on imaging at low magnetic field strengths. , 1990, Magnetic resonance imaging.

[10]  P. Boesiger,et al.  Advances in sensitivity encoding with arbitrary k‐space trajectories , 2001, Magnetic resonance in medicine.

[11]  Oliver Speck,et al.  Parallel imaging in non-bijective, curvilinear magnetic field gradients: a concept study , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.

[12]  Maxim Zaitsev,et al.  Simultaneously driven linear and nonlinear spatial encoding fields in MRI , 2011, Magnetic resonance in medicine.

[13]  Magnetic Resonance Imaging with Composite (Dual) Gradients. , 2009, Concepts in magnetic resonance. Part B, Magnetic resonance engineering.

[14]  Jurek A Nordmeyer-Massner,et al.  NMR probes for measuring magnetic fields and field dynamics in MR systems , 2008, Magnetic resonance in medicine.

[15]  K F King,et al.  Concomitant gradient field effects in spiral scans , 1999, Magnetic resonance in medicine.

[16]  R. T. Constable,et al.  Null Space Imaging : a Novel Gradient Encoding Strategy for Highly Efficient Parallel Imaging , 2009 .

[17]  K. Pruessmann,et al.  Spatiotemporal magnetic field monitoring for MR , 2008, Magnetic resonance in medicine.

[18]  Maxim Zaitsev,et al.  Reconstruction of MRI data encoded with arbitrarily shaped, curvilinear, nonbijective magnetic fields , 2010, Magnetic resonance in medicine.

[19]  Dwight G Nishimura,et al.  Time‐optimal multidimensional gradient waveform design for rapid imaging , 2004, Magnetic resonance in medicine.

[20]  Maxim Zaitsev,et al.  Practical considerations for in vivo MRI with higher dimensional spatial encoding , 2012, Magnetic Resonance Materials in Physics, Biology and Medicine.

[21]  J A Frank,et al.  Simple correction method for k-space trajectory deviations in MRI. , 1998, Journal of magnetic resonance.

[22]  Matteo Pavan,et al.  Higher order reconstruction for MRI in the presence of spatiotemporal field perturbations , 2011, Magnetic resonance in medicine.

[23]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[24]  Klaas P Pruessmann,et al.  A transmit/receive system for magnetic field monitoring of in vivo MRI , 2009, Magnetic resonance in medicine.

[25]  R. Constable,et al.  Spin dephasing under nonlinear gradients: Implications for imaging and field mapping , 2012, Magnetic resonance in medicine.

[26]  J. Hennig,et al.  Monoplanar gradient system for imaging with nonlinear gradients , 2015, Magnetic Resonance Materials in Physics, Biology and Medicine.

[27]  Maria A. Stuchly,et al.  Peripheral nerve stimulation by gradient switching fields in magnetic resonance imaging , 2004, IEEE Transactions on Biomedical Engineering.

[28]  C. Pierpaoli,et al.  Characterization of and correction for eddy current artifacts in echo planar diffusion imaging , 1998, Magnetic resonance in medicine.

[29]  Stephen P. Boyd,et al.  Convex Optimization , 2004, Algorithms and Theory of Computation Handbook.

[30]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[31]  D. O. Walsh,et al.  Adaptive reconstruction of phased array MR imagery , 2000, Magnetic resonance in medicine.