Tribology of Human and Artificial Joints

Studies of human joint lubrication mechanisms have led to the conclusion that under normal healthy conditions they are fluid film lubricated. The main features responsible for allowing this mechanism to operate are the dynamic nature of the loading and the compliance of the bearing surfaces (articular cartilage). In contrast, artificial joints, being made of much more rigid materials, have been demonstrated to be lubricated by a mixed regime, where some load is carried by the fluid film and some by solid to solid contact. Since some surface contact takes place then wear remains a problem and friction is much higher than in human joints. The use of compliant surface bearings for artificial joints has been explored and shown to be of great advantage, reproducing the effects of natural joints. However, elastomeric materials are known to degrade in aqueous solutions so this aspect has been examined to ensure a reasonable life in the human body. Joints of the lower limb—hip, knee and ankle—have similar load and motion patterns and behave in a similar way in terms of lubrication. Joints of the hand are not in any way similar in their behaviour and so a typical upper limb joint, the finger, has been studied to see if improvements can be made to the design of replacement artificial joints. Novel suggestions like plastic on plastic joints have been shown to be an alternative which is worthy of further consideration.

[1]  A Unsworth,et al.  Soft layered prostheses for arthritic hip joints: a study of materials degradation. , 1991, Journal of biomedical engineering.

[2]  D. Dowson,et al.  Mode of aggregation of hyaluronic acid protein complex on the surface of articular cartilage. , 1970, Annals of the rheumatic diseases.

[3]  D. Dowson Paper 12: Modes of Lubrication in Human Joints , 1966 .

[4]  M. Macconaill The Function of Intra-Articular Fibrocartilages, with Special Reference to the Knee and Inferior Radio-Ulnar Joints. , 2022, Journal of anatomy.

[5]  EricShirley Jones,et al.  NOTES, COMMENTS, AND ABSTRACTSJOINT LUBRICATION , 1934 .

[6]  C. Kosack,et al.  LABORATORY , 1949, American journal of public health and the nation's health.

[7]  F. C. Linn,et al.  Lubrication of animal joints. 3. The effect of certain chemical alterations of the cartilage and lubricant. , 1968, Arthritis and rheumatism.

[8]  L. Dintenfass LUBRICATION IN SYNOVIAL JOINTS: A THEORETICAL ANALYSIS. , 1963, The Journal of bone and joint surgery. American volume.

[9]  F. C. Linn,et al.  Lubrication of animal joints. I. The arthrotripsometer. , 1967, The Journal of bone and joint surgery. American volume.

[10]  D. Dowson,et al.  The Influence of Bone and Bone Cement Debris on Counterface Roughness in Sliding Wear Tests of Ultra-High Molecular Weight Polyethylene on Stainless Steel , 1990, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[11]  C W McCutchen Joint lubrication. , 1983, Bulletin of the Hospital for Joint Diseases Orthopaedic Institute.

[12]  F. C. Linn Lubrication of Animal Joints , 1969 .

[13]  D. Dowson,et al.  Behaviour of synovial fluid on surfaces of articular cartilage. A scanning electron microscope study. , 1969, Annals of the rheumatic diseases.

[14]  O. Reynolds IV. On the theory of lubrication and its application to Mr. Beauchamp tower’s experiments, including an experimental determination of the viscosity of olive oil , 1886, Philosophical Transactions of the Royal Society of London.

[15]  G. Higginson,et al.  Hydrodynamic Lubrication of Soft Solids , 1970 .

[16]  Macconaill Ma The Function of Intra-Articular Fibrocartilages, with Special Reference to the Knee and Inferior Radio-Ulnar Joints , 1932 .

[17]  D. Dowson,et al.  Micro-elastohydrodynamic lubrication of synovial joints. , 1986, Engineering in medicine.

[18]  B. J. Roberts The lubrication of natural and artificial hip joints , 1982 .

[19]  G. Higginson,et al.  The Lubrication of Porous Elastic Solids with Reference to the Functioning of Human Joints , 1974 .

[20]  A. Unsworth,et al.  Frictional properties of artificial hip joints. , 1988, Engineering in medicine.

[21]  J CHARNLEY,et al.  The Lubrication of Animal Joints in Relation to Surgical Reconstruction by Arthroplasty * , 1960, Annals of the rheumatic diseases.

[22]  Jb Morrison Bioengineering analysis of force actions transmitted by the knee joint , 1970 .

[23]  R. Tanner An alternative mechanism for the lubrication of synovial joints. , 1966, Physics in medicine and biology.

[24]  A Unsworth,et al.  Modes of lubrication in human hip joints. , 1982, Annals of the rheumatic diseases.

[25]  D Dowson,et al.  "Boosted lubrication" of human joints by fluid enrichment and entrapment. , 1969, Biomedical engineering.

[26]  Duncan Dowson,et al.  The Frictional Behavior of Human Synovial Joints—Part I: Natural Joints , 1975 .

[27]  D. Dowson,et al.  Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints: I: Charnley prostheses with polytetrafluoroethylene acetabular cups , 1985 .

[28]  J. P. Paul,et al.  Paper 8: Forces Transmitted by Joints in the Human Body: , 1966 .

[29]  R. Fein Research Report 3: Are Synovial Joints Squeeze-Film Lubricated? , 1966 .

[30]  G. Higginson,et al.  Fluid entrapment by a soft surface layer , 1974 .

[31]  A Unsworth,et al.  A Finger Function Simulator and the Laboratory Testing of Joint Replacements , 1990, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[32]  F. C. Linn,et al.  Lubrication of animal joints. II. The mechanism. , 1968, Journal of biomechanics.

[33]  C. McCutchen,et al.  Mechanism of Animal Joints: Sponge-hydrostatic and Weeping Bearings , 1959, Nature.

[34]  Duncan Dowson,et al.  A Study of the Role of Synovial Fluid and its Constituents in the Friction and Lubrication of Human Hip Joints , 1978 .

[35]  C. McCutchen Sponge-hydrostatic and weeping bearings. , 1959, Nature.

[36]  D Dowson,et al.  "Boosted lubrication" in synovial joints by fluid entrapment and enrichment. , 1968, Annals of the rheumatic diseases.

[37]  A. Unsworth,et al.  Wear of cross-linked polyethylene against itself: a material suitable for surface replacement of the finger joint. , 1991, Journal of biomedical engineering.

[38]  T. English,et al.  In vivo records of hip loads using a femoral implant with telemetric output (a preliminary report). , 1979, Journal of biomedical engineering.