A row-column addressed micromachined ultrasonic transducer array for surface scanning applications.

Row-column addressed arrays for ultrasonic non-destructive testing (NDT) applications are analyzed and demonstrated in this paper. Simulation and experimental results of a row-column addressed 32 by 32 capacitive micromachined ultrasonic transducer (CMUT) array are presented. The CMUT array, which was designed for medical imaging applications, has a center frequency of 5.3MHz. The CMUT array was used to perform C-scans on test objects with holes that have diameters of 1.0mm and 0.5mm. The array transducer has an aperture size of 4.8mm by 4.8mm, and it was used to scan an area of 4.0mm by 4.0mm. Compared to an N by N fully addressed 2-D array, a row-column addressed array of the same number of elements requires fewer (N instead of N(2)) pairs of interconnection and supporting electronic components such as pulsers and amplifiers. Even though the resulting field of view is limit by the aperture size, row-column addressed arrays and the row-column addressing scheme can be an alternative option of 2-D arrays for NDT applications.

[1]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[2]  Chi Hyung Seo,et al.  A 256 x 256 2-D array transducer with row-column addressing for 3-D rectilinear imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Steve Mahaut,et al.  Development of phased array techniques to improve characterization of defect located in a component of complex geometry. , 2002, Ultrasonics.

[4]  P. Wilcox,et al.  Post-processing of the full matrix of ultrasonic transmit-receive array data for non-destructive evaluation , 2005 .

[5]  Roger J. Zemp,et al.  S-sequence bias-encoded photoacoustic imaging with top Orthogonal to Bottom Electrode (TOBE) CMUT arrays , 2013, 2013 IEEE International Ultrasonics Symposium (IUS).

[6]  B. Khuri-Yakub,et al.  Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging? , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  J. Yeow,et al.  Fabricating capacitive micromachined ultrasonic transducers with a novel silicon-nitride-Based wafer bonding process , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  Anthony Gachagan,et al.  Application of conformal map theory for design of 2-D ultrasonic array structure for ndt imaging application: a feasibility study , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[9]  Morten Willatzen,et al.  Simulating capacitive micromachined ultrasonic transducers (CMUTs) using field II , 2010, 2010 IEEE International Ultrasonics Symposium.

[10]  Bruce W. Drinkwater,et al.  An ultrasonic wheel-array sensor and its application to aerospace structures , 2003 .

[11]  L. G. Ullate,et al.  A small 2D ultrasonic array for NDT applications , 2003 .

[12]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[13]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[14]  Paul D. Wilcox,et al.  Design of Two-Dimensional Ultrasonic Phased Array Transducers , 2005 .

[15]  Ultrasound Transducers Calculation of Pressure Fields from Arbitrarily Shaped, Apodized, and Excited , 1992 .

[16]  Roger Zemp,et al.  Top-orthogonal-to-bottom-electrode (TOBE) CMUT arrays for 3-D ultrasound imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[17]  J. Yeow,et al.  A 32 x 32 element row-column addressed capacitive micromachined ultrasonic transducer , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  A. Gachagan,et al.  An annular array with fiber composite microstructure for far field NDT imaging applications , 2009, 2009 IEEE International Ultrasonics Symposium.

[19]  K. Wall,et al.  Real-time volume imaging using a crossed electrode array , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  R A Smith,et al.  Rapid ultrasonic inspection of ageing aircraft , 2003 .

[21]  Paul D. Wilcox,et al.  Ultrasonic arrays for non-destructive evaluation: A review , 2006 .

[22]  G.R. Lockwood,et al.  Theoretical assessment of a crossed electrode 2-D array for 3-D imaging , 2003, IEEE Symposium on Ultrasonics, 2003.

[23]  Edward Hæggström,et al.  Fabricating capacitive micromachined ultrasonic transducers with wafer-bonding technology , 2003 .

[24]  John T. W. Yeow,et al.  2-D CMUT wafer bonded imaging arrays with a row-column addressing scheme , 2009, 2009 IEEE International Ultrasonics Symposium.

[25]  D. Mills Medical imaging with capacitive micromachined ultrasound transducer (cMUT) arrays , 2004, IEEE Ultrasonics Symposium, 2004.