NuSTAR ground calibration: The Rainwater Memorial Calibration Facility (RaMCaF)

The Nuclear Spectroscopic Telescope Array (NuSTAR) is a NASA Small Explorer mission that will carry the first focusing hard X-ray (5-80 keV ) telescope to orbit. The ground calibration of the three flight optics was carried out at the Rainwater Memorial Calibration Facility (RaMCaF) built for this purpose. In this article we present the facility and its use for the ground calibration of the three optics.

[1]  Carsten P. Jensen,et al.  Development and production of hard X-ray multilayer optics for HEFT , 2003, SPIE Astronomical Telescopes + Instrumentation.

[2]  Alex Zehnder,et al.  The Reuven Ramaty high-energy solar spectroscopic imager (RHESSI) mission , 2003, SPIE Optics + Photonics.

[3]  Finn Erland Christensen,et al.  Evaluation and optimization of multilayer designs for astronomical x-ray telescopes using a field-of-view- and energy-dependent figure of merit , 2000, SPIE Optics + Photonics.

[4]  Kristin K. Madsen,et al.  The Rainwater Memorial Calibration Facility for X-Ray Optics , 2011 .

[5]  Gordon Tajiri,et al.  Fabrication of the NuSTAR flight optics , 2011, Optical Engineering + Applications.

[6]  Regina Soufli,et al.  Atomic force microscopy characterization of Zerodur mirror substrates for the extreme ultraviolet telescopes aboard NASA's Solar Dynamics Observatory. , 2007, Applied optics.

[7]  Peter Mao,et al.  The Nuclear Spectroscopic Telescope Array (NuSTAR) , 2010, Astronomical Telescopes + Instrumentation.

[8]  Niels Jørgen Stenfeldt Westergaard MT_RAYOR: a versatile raytracing tool for x-ray telescopes , 2011, Optical Engineering + Applications.

[9]  William W. Zhang,et al.  The Nuclear Spectroscopic Telescope Array (NuSTAR): optics overview and current status , 2010, Astronomical Telescopes + Instrumentation.

[10]  Aleksey E. Bolotnikov,et al.  Development of the High-Energy Focusing Telescope (HEFT) balloon experiment , 2000, Astronomical Telescopes and Instrumentation.

[11]  Heike Soltau,et al.  Expanding the detection efficiency of silicon drift detectors , 2010 .

[12]  John M. Boone,et al.  Development of a high-speed CT imaging system using EMCCD camera , 2009, Medical Imaging.

[13]  E L Church,et al.  Specification of surface figure and finish in terms of system performance. , 1993, Applied optics.

[14]  Michael J. Pivovaroff,et al.  Application of an EMCCD camera for calibration of hard x-ray telescopes , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[15]  Haitao Yu,et al.  Production and calibration of the first HEFT hard x-ray optics module , 2004, SPIE Optics + Photonics.

[16]  Eugene L. Church,et al.  Specification of glancing- and normal-incidence x-ray mirrors [also Erratum 34(11)3348(Nov1995)] , 1995 .

[17]  David L. Windt,et al.  IMD—software for modeling the optical properties of multilayer films , 1998 .

[18]  Christopher J. Hall,et al.  X-ray calibration of the SODART flight telescopes , 1997, Optics & Photonics.