A Comparative Study of Gas Holdup, Bubble Size Distribution and Interfacial Area in a Downflow Bubble Column

Experimental investigations have been carried out in an ejector induced downflow bubble column with special emphasis on gas holdup, bubble size distribution and interfacial area. Bubble diameters have been measured by photographic and capillary method at different operating conditions. Bubble sizes are found to have a logarithmic-normal probability distribution for any axial positions of the column. Sauter mean bubble diameters have been used along with overall gas holdup to get the geometric interfacial area and the results are compared with the interfacial area obtained by chemical method. Experiments are carried out with air–water system in bubbly flow regime. Absorption of carbon dioxide in aqueous sodium hydroxide solution has been adopted to measure interfacial area by chemical method. The discrepancies in interfacial area obtained by the two methods are found to be consistent with reported works.

[1]  Kiyomi Akita,et al.  Bubble Size, Interfacial Area, and Liquid-Phase Mass Transfer Coefficient in Bubble Columns , 1974 .

[2]  A. K. Biń,et al.  Gas entrainment by plunging liquid jets , 1988 .

[3]  Arvo Lannus,et al.  Gas‐Liquid Reactions , 1970 .

[4]  T. Ishikura,et al.  Mass transfer characteristics in gas bubble dispersed phase generated by plunging jet containing small solute bubbles , 2001 .

[5]  Gautam Kundu,et al.  Gas holdup and entrainment characteristics in a modified downflow bubble column with Newtonian and non-Newtonian liquid , 2003 .

[6]  Clemens Merten,et al.  Bubble size distributions in a bubble column reactor under industrial conditions , 2002 .

[7]  Michel Roustan,et al.  A comparative study of gas hold-up, bubble size, interfacial area and mass transfer coefficients in stirred gas–liquid reactors and bubble columns , 2001 .

[8]  H. Blanch,et al.  Bubble coalescence and break‐up in air‐sparged bubble columns , 1990 .

[9]  Domenico Colella,et al.  A study on coalescence and breakage mechanisms in three different bubble columns , 1999 .

[10]  W.-D. Deckwer,et al.  Analysis of chemical methods for determination of interfacial areas in gas-in-liquid dispersions with non-uniform bubble sizes , 1980 .

[11]  Rajarathinam Parthasarathy,et al.  Size Distribution of Bubbles Generated by Fine-Pore Spargers , 1996 .

[12]  A. Ohkawa,et al.  BUBBLE SIZE, INTERFACIAL AREA AND VOLUMETRIC LIQUID-PHASE MASS TRANSFER COEFFICIENT IN DOWNFLOW BUBBLE COLUMNS WITH GAS ENTRAINMENT BY A LIQUID JET , 1987 .

[13]  T. Miyahara,et al.  Size of Bubbles Generated from Perforated Plates in Non-Newtonian Liquids , 1995 .

[14]  A. K. Mitra,et al.  Experimental studies on a co-current gas-liquid downflow bubble column , 1995 .

[15]  V. Linek,et al.  Hydrodynamic and mass transfer characteristics of ejector loop reactors , 2000 .

[16]  K. V. Raghavan,et al.  Mass transfer and hydrodynamic characteristics of loop reactors with downflow liquid jet ejector , 1987 .