A 32×32 integrated CMUT array for volumetric ultrasound imaging

Real-time 3D volumetric ultrasound imaging systems require transmit and receive circuitry to generate the ultrasound beam and process the received echo signals. Since a 2D array is required for 3D imaging, the complexity of building such a system is significantly higher, e.g., front-end electronics need to be interfaced to the transducer, a large number of elements need to be interfaced to the backend system and a large dataset needs to be processed. In this work, we present a 3D imaging system using capacitive micromachined ultrasonic transducer (CMUT) technology that addresses many of the challenges in building such a system. The transducer is a 5-MHz CMUT array with an 8 mm × 8 mm aperture size. The aperture consists of 1024 elements (32×32) with an element pitch of 250 μm. An integrated circuit (IC) is integrated very close to the CMUT array. It consists of a transmit beamformer and receive circuitry to improve the noise performance of the overall system. Simultaneous multi-beam transmit is also incorporated in the IC to improve the imaging frame rate. The CMUT is flip-chip bonded to the IC and the final assembly measured 9.2 mm × 9.2 mm. The assembly was then interfaced with an FPGA and a backend system (comprising of a data acquisition system and PC). The FPGA provided the digital I/O signals for the IC and the backend system was used to process the received RF echo data (from the IC) and reconstruct the volume image using a phased array imaging approach. Imaging experiments were performed using wire phantoms. Real-time volumetric images were captured at 5 volumes per second and are presented in this paper.

[1]  Amin Nikoozadeh,et al.  3D volumetric ultrasound imaging with a 32×32 CMUT array integrated with front-end ICs using flip-chip bonding technology , 2013, 2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers.

[2]  B. Khuri-Yakub,et al.  Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging? , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  M. Schubert,et al.  5 V-to-75 V CMOS output interface circuits , 1993, 1993 IEEE International Solid-State Circuits Conference Digest of Technical Papers.

[4]  O. Oralkan,et al.  Real-time volumetric imaging system for CMUT arrays , 2011, 2011 IEEE International Ultrasonics Symposium.

[5]  Amin Nikoozadeh,et al.  Forward-looking volumetric intracardiac imaging using a fully integrated CMUT ring array , 2009, 2009 IEEE International Ultrasonics Symposium.

[6]  Butrus T. Khuri-Yakub,et al.  Beamforming and hardware design for a multichannel front-end integrated circuit for real-time 3D catheter-based ultrasonic imaging , 2006, SPIE Medical Imaging.

[7]  O. Oralkan,et al.  Capacitive micromachined ultrasonic transducers: fabrication technology , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  A. Nikoozadeh,et al.  An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  Wesley Lee,et al.  Three‐ and 4‐Dimensional Ultrasound in Obstetrics and Gynecology , 2005, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.