Charge-based particle separation in microfluidic devices using combined hydrodynamic and electrokinetic effects.

A new microfluidic approach for charge-based particle separation using combined hydrodynamic and electrokinetic effects is presented. A recirculating flow pattern is employed, generated through application of bi-directional flow in a narrow glass microchannel incorporating diverging or converging segments at both ends. The bi-directional flow in turn is a result of opposing pressure-driven flow and electro-osmotic flow in the device. Trapping and preconcentration of charged particles is observed in the recirculating flow, under conditions where the average net velocity of the particles themselves approaches zero. This phenomenon is termed flow-induced electrokinetic trapping (FIET). Importantly, the electrophoretic mobility (zeta potential) of the particles determines the flow conditions required for trapping. In this paper, we exploit FIET for the first time to perform particle separations. Using a non-uniform channel, one type of particle can be trapped according to its zeta-potential, while particles with higher or lower zeta-potentials are flushed away with the pressure-driven or electro-osmotic components, respectively, of the flow. This was demonstrated using simple mixtures of two polystyrene bead types having approximately the same size (3 microm) but different zeta potentials (differences were in the order of 25 to 40 mV). To gain more insight into the separation mechanism, particle separations in straight, 3 cm-long microchannels with uniform cross-section were also studied under conditions of bi-directional flow without trapping. A thorough theoretical analysis confirmed that trapping occurs when electrokinetic and pressure-driven particle velocities are equal and opposite throughout the diverging segment. This makes it possible to predict the pressure and electric field conditions required to separate particles having defined zeta potentials.

[1]  Otto Leistiko,et al.  A novel approach to the automation of clinical chemistry by controlled manipulation of magnetic particles , 1999 .

[2]  S. Mangru,et al.  Dynamic DNA hybridization on a chip using paramagnetic beads. , 1999, Analytical chemistry.

[3]  P. Sandra,et al.  Capillary zone electrophoresis for the characterization of latex particles , 2001, Electrophoresis.

[4]  C. Culbertson,et al.  Flow Counterbalanced Capillary Electrophoresis , 1994 .

[5]  A. Manz,et al.  Miniaturized total chemical analysis systems: A novel concept for chemical sensing , 1990 .

[6]  M. McClain,et al.  Microfluidic devices for the high-throughput chemical analysis of cells. , 2003, Analytical chemistry.

[7]  N. Mozes Microbial cell surface analysis : structural and physico-chemical methods , 1991 .

[8]  R. Oleschuk,et al.  Capillary‐based solid‐phase extraction with columns prepared using different bead trapping methods , 2005, Electrophoresis.

[9]  D. R. Morrison,et al.  Cellular electrophoretic mobility data: A first approach to a database , 1997, Electrophoresis.

[10]  D. Burgreen,et al.  Electrokinetic Flow in Ultrafine Capillary Slits1 , 1964 .

[11]  R. E. Oosterbroek,et al.  On-chip hydrodynamic chromatography separation and detection of nanoparticles and biomolecules. , 2003, Analytical chemistry.

[12]  Thomas W. Martinek,et al.  Electroviscous Fluids. I. Rheological Properties , 1967 .

[13]  Elisabeth Verpoorte,et al.  An integrated fritless column for on-chip capillary electrochromatography with conventional stationary phases. , 2002, Analytical chemistry.

[14]  Albert van den Berg,et al.  A chip system for size separation of macromolecules and particles by hydrodynamic chromatography. , 2002, Analytical chemistry.

[15]  Klavs F Jensen,et al.  Continuous dielectrophoretic size-based particle sorting. , 2006, Analytical chemistry.

[16]  D J Harrison,et al.  mRNA isolation in a microfluidic device for eventual integration of cDNA library construction. , 2000, The Analyst.

[17]  R. McCormick,et al.  Separation and Isolation of Viable Bacteria by Capillary Zone Electrophoresis , 1993, Nature Biotechnology.

[18]  N. D. de Rooij,et al.  A novel microfluidic concept for bioanalysis using freely moving beads trapped in recirculating flows. , 2003, Lab on a chip.

[19]  C. Guttman,et al.  Separation by Flow , 1970 .

[20]  G. Christian,et al.  Flow injection renewable surface immunoassay for real time monitoring of biospecific interactions. , 1997, Analytical chemistry.

[21]  R. Oleschuk,et al.  Trapping of bead-based reagents within microfluidic systems: on-chip solid-phase extraction and electrochromatography , 2000, Analytical chemistry.

[22]  A. Chrambach,et al.  Separation and characterization of sub‐μm‐ and μm‐sized particles by capillary zone electrophoresis , 2002 .

[23]  Kurt Seiler,et al.  Electroosmotic Pumping and Valveless Control of Fluid Flow within a Manifold of Capillaries on a Glass Chip , 1994 .

[24]  Sungyoung Choi,et al.  Microfluidic system for dielectrophoretic separation based on a trapezoidal electrode array. , 2005, Lab on a chip.

[25]  D. A. Saville,et al.  The dynamics of electrophoresis , 1991 .

[26]  Chun-Ping Jen,et al.  Mechanism of hydrodynamic separation of biological objects in microchannel devices. , 2002, Lab on a chip.

[27]  T. Welsch,et al.  Determination of the electrophoretic mobility of bacteria and their separation by capillary zone electrophoresis , 1997 .

[28]  Thomas Laurell,et al.  Acoustic control of suspended particles in micro fluidic chips. , 2004, Lab on a chip.

[29]  Peter Enoksson,et al.  Micromachined flow-through filter-chamber for chemical reactions on beads , 2000 .

[30]  Nicole Pamme,et al.  Rapid on-chip multi-step (bio)chemical procedures in continuous flow--manoeuvring particles through co-laminar reagent streams. , 2008, Chemical communications.

[31]  Minoru Seki,et al.  Continuous and precise particle separation by electroosmotic flow control in microfluidic devices , 2008, Electrophoresis.

[32]  H. Busscher,et al.  AUTOMATED IMAGE-ANALYSIS TO DETERMINE ZETA-POTENTIAL DISTRIBUTIONS IN PARTICULATE MICROELECTROPHORESIS , 1993 .

[33]  M. H. Davis Electrostatic Field and Force on a Dielectric Sphere near a Conducting Plane—A Note on the Application of Electrostatic Theory to Water Droplets , 1969 .

[34]  H. C. van der Mei,et al.  Influence of Culture Heterogeneity in Cell Surface Charge on Adhesion and Biofilm Formation by Enterococcus faecalis , 2006, Journal of bacteriology.

[35]  Universal dynamics in the onset of a Hagen-Poiseuille flow. , 2005, Physical review. E, Statistical, nonlinear, and soft matter physics.

[36]  J. Voldman,et al.  Dielectrophoretic registration of living cells to a microelectrode array. , 2004, Biosensors & bioelectronics.

[37]  M. Yamada,et al.  Hydrodynamic filtration for on-chip particle concentration and classification utilizing microfluidics. , 2005, Lab on a chip.

[38]  R. E. Robertson,et al.  Alignment of particles by an electric field , 1998 .

[39]  G. McIntire,et al.  Analytical separation of polystyrene nanospheres by capillary electrophoresis , 1989 .

[40]  Dongqing Li,et al.  ELECTRICAL DOUBLE LAYER POTENTIAL DISTRIBUTION IN A RECTANGULAR MICROCHANNEL , 1998 .

[41]  C. L. Rice,et al.  Electrokinetic Flow in a Narrow Cylindrical Capillary , 1965 .

[42]  A. Berg,et al.  Micro Total Analysis Systems , 1995 .

[43]  E. Cummings,et al.  Dielectrophoretic concentration and separation of live and dead bacteria in an array of insulators. , 2004, Analytical chemistry.

[44]  D. Armstrong,et al.  Separation, Identification, and Characterization of Microorganisms by Capillary Electrophoresis , 2003, Microbiology and Molecular Biology Reviews.

[45]  M. Yamada,et al.  Pinched flow fractionation: continuous size separation of particles utilizing a laminar flow profile in a pinched microchannel. , 2004, Analytical chemistry.

[46]  T Kitamori,et al.  Integration of an immunosorbent assay system: analysis of secretory human immunoglobulin A on polystyrene beads in a microchip. , 2000, Analytical chemistry.

[47]  Xunli Zhang,et al.  Continuous flow separation of particles within an asymmetric microfluidic device. , 2006, Lab on a chip.

[48]  J. Sturm,et al.  Continuous Particle Separation Through Deterministic Lateral Displacement , 2004, Science.

[49]  Ciprian Iliescu,et al.  Continuous field-flow separation of particle populations in a dielectrophoretic chip with three dimensional electrodes , 2007 .

[50]  D. Beebe,et al.  A particle image velocimetry system for microfluidics , 1998 .

[51]  Sungyoung Choi,et al.  Continuous hydrophoretic separation and sizing of microparticles using slanted obstacles in a microchannel. , 2007, Lab on a chip.