The application of the bioelectric recognition assay for the detection of human and plant viruses: definition of operational parameters.

The bioelectric recognition assay (BERA) is a novel biosensory method based on a unique combination of a group of cells, their immobilization in a matrix that preserves their physiological functions and the expression of the cell interaction with viruses as a change in electrical properties. A BERA sensor consists of an electroconductive, tube-like probe containing components of immobilized cells in a gel matrix. Cells are selected to specifically interact with the virus under detection. In this way, when a positive sample is added to the probe, a characteristic, 'signature-like' change in electrical potential occurs upon contact between the virus and the gel matrix. In the present study, we demonstrate that BERA can be used for the detection of viruses in humans (hepatitis C virus) and plants (tobacco and cucumber viruses) in a remarkably specific, rapid (1-2 min), reproducible and cost-efficient fashion. The sensitivity of the virus detection with BERA (0.1 ng) is equal or even better than with advanced immunological, cytological and molecular techniques, such as the reverse transcription polymerase chain reaction. Moreover, a good storability of the sensors can be achieved without affecting their performance. The potential use of portable BERA biosensors in medicine, for mass screening purposes, as well as for the detection of biological warfare agents without prior knowledge of a specific receptor-molecule interaction is discussed.

[1]  U. Koch,et al.  Detection of volatiles released by diseased potato tubers using a biosensor on the basis of intact insect antennae , 1999 .

[2]  Dietrich Knorr,et al.  Impact of high-intensity electric field pulses on plant membrane permeabilization , 1998 .

[3]  O. Hamill,et al.  On the discrepancy between whole‐cell and membrane patch mechanosensitivity in Xenopus oocytes , 2000, The Journal of physiology.

[4]  H. Coster,et al.  Spatial Variation of the Electrical Properties of Chara australis. I Electrical Potentials and Membrane Conductance , 1983 .

[5]  S. MacFarlane Rapid cloning of uncharacterised tobacco rattle virus isolates using long template (LT) PCR. , 1996, Journal of virological methods.

[6]  R N Zare,et al.  Screening of receptor antagonists using agonist-activated patch clamp detection in chemical separations. , 1998, Analytical chemistry.

[7]  S. Thung,et al.  HCV RNA levels in hepatocellular carcinomas and adjacent non-tumorous livers. , 2000, Journal of virological methods.

[8]  Jean-Louis Marty,et al.  Biosensors for the detection of pesticides , 1998 .

[9]  H E Hummel,et al.  Insect-based BioFETs with improved signal characteristics. , 1999, Biosensors & bioelectronics.

[10]  J. Hernández,et al.  Detection of HCV and GBV-CHGV RNA in peripheral blood mononuclear cells of patients with chronic type C hepatitis. , 2000, Microbios.

[11]  A. Hoekema,et al.  A small-scale procedure for the rapid isolation of plant RNAs. , 1989, Nucleic acids research.

[12]  J. Smith The Electrical Properties of Plant Cell Membranes: Cable Properties involving the Plasmalemma, Tonoplast and Cytoplasm in Chara , 1983 .

[13]  N. Siafakas,et al.  Development of a quadriplex polymerase chain reaction for human cytomegalovirus detection , 1999, Journal of clinical laboratory analysis.

[14]  S. Komori,et al.  Modification of membrane currents in mouse neuroblastoma cells following infection with rabies virus , 1999, British journal of pharmacology.

[15]  R. Lamb,et al.  Direct measurement of the influenza A virus M2 protein ion channel activity in mammalian cells. , 1994, Virology.

[16]  G. Nemo,et al.  HEPATITIS C VIRUS INFECTION IN POST-TRANSFUSION HEPATITIS - AN ANALYSIS WITH FIRST - AND SECOND - GENERATION ASSAYS , 1991 .

[17]  M. Busch,et al.  Analysis of hepatitis C virus RNA prevalence and surrogate markers of infection among seropositive voluntary blood donors , 1993, Hepatology.

[18]  J. Rosenblatt,et al.  Detection of hepatitis C viral sequences in non-A, non-B hepatitis , 1990, The Lancet.

[19]  M. Houghton,et al.  Molecular biology of the hepatitis C viruses: Implications for diagnosis, development and control of viral disease , 1991, Hepatology.

[20]  Derek J. F. Brown,et al.  The association between species of Trichodorus and Paratrichodorus vector nematodes and serotypes of tobacco rattle tobravirus , 1992 .

[21]  C. A. Knight,et al.  The coat protein subunits of cucumber viruses 3 and 4 and a comparison of methods for determining their molecular weights. , 1972, Virology.

[22]  B. Maresca,et al.  Does the membrane's physical state control the expression of heat shock and other genes? , 1998, Trends in biochemical sciences.

[23]  A. Turner,et al.  Whole-cell biosensors for environmental monitoring. , 1989, Biosensors.

[24]  C. Bracker,et al.  Defectiveness and dependence in three related strains of tobacco rattle virus. , 1969, Virology.

[25]  L. Jaffe Fast block to polyspermy in sea urchin eggs is electrically mediated , 1976, Nature.

[26]  Brian R. Eggins,et al.  Biosensors: An Introduction , 1997 .

[27]  P. Fromherz,et al.  A neuron-silicon junction: a Retzius cell of the leech on an insulated-gate field-effect transistor. , 1991, Science.

[28]  H. Shapiro,et al.  Cell membrane potential changes follow epstein‐barr virus binding , 1983, Journal of cellular physiology.

[29]  R. Astumian,et al.  Electroconformational coupling: how membrane-bound ATPase transduces energy from dynamic electric fields. , 1988, Annual review of physiology.

[30]  F. Bem,et al.  Bioelectric recognition assay (BERA). , 2001, Biosensors & bioelectronics.

[31]  P. Simmonds,et al.  Serological responses to infection with three different types of hepatitis C virus , 1991, The Lancet.