Radiometric Calibration for AgCam

The student-built Agricultural Camera (AgCam) now onboard the International Space Station observes the Earth surface through two linescan cameras with Charge-Coupled Device (CCD) arrays sensitive to visible and near-infrared wavelengths, respectively. The electro-optical components of the AgCam were characterized using precision calibration equipment; a method for modeling and applying these measurements was derived. Correction coefficients to minimize effects of optical vignetting, CCD non-uniform quantum efficiency, and CCD dark current are separately determined using a least squares fit approach. Application of correction coefficients yields significant variability reduction in flat-field images; comparable results are obtained when applied to ground test images.

[1]  R. Denham,et al.  An operational radiometric calibration procedure for the Landsat sensors based on pseudo-invariant target sites , 2007 .

[2]  Pavel Hajek,et al.  Radiometric validation of NASA's Ames Research Center's Sensor Calibration Laboratory. , 2005, Applied optics.

[3]  Chi-Keung Tang,et al.  Tensor voting for image correction by global and local intensity alignment , 2005, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[4]  P. Sellers Canopy reflectance, photosynthesis and transpiration , 1985 .

[5]  D. Diner,et al.  The MISR radiometric calibration process , 2007 .

[6]  Dan B. Goldman,et al.  Vignette and exposure calibration and compensation , 2005, Tenth IEEE International Conference on Computer Vision (ICCV'05) Volume 1.

[7]  Dennis G. Socker,et al.  Modulation transfer function measurement technique for small-pixel detectors. , 1992, Applied optics.

[8]  Stephen Lin,et al.  Single-Image Vignetting Correction , 2006, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[9]  J. Haba,et al.  Status and perspectives of Pixelated Photon Detector (PPD) , 2008 .

[10]  Agnès Bégué,et al.  Can Commercial Digital Cameras Be Used as Multispectral Sensors? A Crop Monitoring Test , 2008, Sensors.

[11]  Frank M. Candocia Jointly registering images in domain and range by piecewise linear comparametric analysis , 2003, IEEE Trans. Image Process..

[12]  R. Mcintyre,et al.  Photon counting techniques with silicon avalanche photodiodes. , 1993, Applied optics.

[13]  Yücel Altunbasak,et al.  A fast parametric motion estimation algorithm with illumination and lens distortion correction , 2003, IEEE Trans. Image Process..

[14]  Wonpil Yu,et al.  Practical anti-vignetting methods for digital cameras , 2004, IEEE Trans. Consumer Electron..

[15]  Chang-Hee Won,et al.  AgCam: scientific imaging from the ISS Window Observational Research Facility , 2004, 2004 IEEE Aerospace Conference Proceedings (IEEE Cat. No.04TH8720).

[16]  Stephen J. Little,et al.  Flat-Fielding for CCDs in AAVSO Observations, I , 1999 .

[17]  John M. Boone,et al.  Flat-field correction technique for digital detectors , 1998, Medical Imaging.

[18]  S. R. Andrews,et al.  Experimental and theoretical studies of the performance of quantum‐well infrared photodetectors , 1991 .