Low-Power CMOS Interface for Recording and Processing Very Low Amplitude Signals

AbstractIn this paper, we describe a low-power low-voltage CMOS very low signal acquisition analog front-end of sensor electronic interfaces. These interfaces are mainly dedicated to biomedical implantable devices. In this work, we focus on the implantable bladder controller. Since the nerve signal has very low amplitude and low frequency, it is, at first fed to a low-voltage chopper amplifier to reduce the flicker (1/f) noise and then amplified with a programmable gain high CMRR instrumentation amplifier. This is followed by an analog signal processing circuit to rectify and bin-integrate (RBI) the amplified signal. The resulting RBI is then converted to digital and transferred to the implant's central processor where information about bladder can be extracted. The numerous analog modules of the system have been implemented in CMOS 0.35 μm, 3.3 V technology. The design, simulation and measurement results of the proposed interface are presented. At supply voltage of 2.2 V the power dissipation is less than 1.4 mW, the input equivalent noise is 56 nV/ $$\sqrt {{\text{Hz}}} $$ and the error in RBI calculation is less than 0.15%.

[1]  Qiuting Huang,et al.  A low-noise CMOS instrumentation amplifier for thermoelectric infrared detectors , 1997 .

[2]  R. Stein,et al.  Neural prostheses : replacing motor function after disease or disability , 1992 .

[3]  J Kumazawa,et al.  Continuous monitoring of bladder pressure in dogs in a completely physiological state. , 1987, British journal of urology.

[4]  Francois Krummenacher,et al.  A 4-MHz CMOS Continuous-Time Filter with On-Chip Automatic Tuning , 1987, ESSCIRC '87: 13th European Solid-State Circuits Conference.

[5]  D.B. Popovic,et al.  Sensory nerve recording for closed-loop control to restore motor functions , 1993, IEEE Transactions on Biomedical Engineering.

[6]  M M Elhilali,et al.  Role of electric stimulation in bladder evacuation following spinal cord transection. , 1992, The Journal of urology.

[7]  Erik Bruun,et al.  Dynamic range of low-voltage cascode current mirrors , 1995, Proceedings of ISCAS'95 - International Symposium on Circuits and Systems.

[8]  Gabor C. Temes,et al.  Circuit techniques for reducing the effects of op-amp imperfections: autozeroing, correlated double sampling, and chopper stabilization , 1996, Proc. IEEE.

[9]  H. Wijkstra,et al.  Sacral root stimulation in the dog: reduction of urethral resistance , 1993, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ.

[10]  Dennis Feucht,et al.  Handbook of Analog Circuit Design , 1990 .

[11]  M. Elhilali,et al.  Implantable selective stimulator to improve bladder voiding: design and chronic experiments in dogs. , 2000, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[12]  T A Perkins Versatile three-channel stimulation controller for restoration of bladder function in paraplegia. , 1986, Journal of biomedical engineering.

[13]  R. Schmidt,et al.  Electrical stimulation in the clinical management of the neurogenic bladder. , 1988, The Journal of urology.

[14]  B S Nashold,et al.  Electrical activation of micturition by spinal cord stimulation. , 1971, The Journal of surgical research.

[15]  Andrzej Cichocki,et al.  MOS Switched-Capacitor and Continuous-Time Integrated Circuits and Systems: Analysis and Design , 1989 .

[16]  Ishwar D. Aggarwal,et al.  Pulsed laser emission at 2.3 mu m in a thulium-doped fluorozirconate fibre , 1988 .

[17]  F M Debruyne,et al.  Bladder pressure sensors in an animal model. , 1994, The Journal of urology.

[18]  L. E. Baker,et al.  Measurement of urinary bladder emptying using electrical impedance , 2006, Medical and biological engineering.

[19]  M. Haugland,et al.  The use of natural sensory nerve signals as an advanced heel-switch in drop-foot patients , 1992 .

[20]  E. Vittoz,et al.  A CMOS Chopper Amplifier , 1986, ESSCIRC '86: Twelfth European Solid-State Circuits Conference.

[21]  K. Horch,et al.  Information contained in sensory nerve recordings made with intrafascicular electrodes , 1991, IEEE Transactions on Biomedical Engineering.

[22]  B Upshaw,et al.  Digital signal processing algorithms for the detection of afferent nerve activity recorded from cuff electrodes. , 1998, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[23]  Kenzo Watanabe,et al.  Spike-free switched-capacitor circuits , 1987 .

[24]  V Brailovski,et al.  New easy to install nerve cuff electrode using shape memory alloy armature. , 1999, Artificial organs.

[25]  Franco Maloberti,et al.  An accurate CMOS sample-and-hold circuit , 1992 .

[26]  M Sawan,et al.  Implantable volume monitor and miniaturized stimulator dedicated to bladder control. , 1997, Artificial organs.

[27]  R. Stein,et al.  Principles Underlying New Methods for Chronic Neural Recording , 1975, Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques.

[28]  M. Haugland,et al.  Force information in whole human sensory nerve recordings , 1992 .

[29]  Gordon W. Roberts,et al.  High-swing MOS current mirror with arbitrarily high output resistance , 1992 .

[30]  T. R. Viswanathan,et al.  Switched-capacitor integrator with reduced sensitivity to amplifier gain , 1986 .

[31]  M. Sawan,et al.  Proposed new bladder volume monitoring device based on impedance measurement , 2006, Medical and Biological Engineering and Computing.

[32]  Thomas Sinkjær,et al.  Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man , 1995 .