Statistical properties of cerebral CT perfusion imaging systems. Part I. Cerebral blood volume maps generated from nondeconvolution-based systems.

PURPOSE The development and clinical employment of a CT imaging system benefit from a thorough understanding of the statistical properties of the output images; cerebral CT perfusion (CTP) imaging system is no exception. A series of articles will present statistical properties of CTP systems and the dependence of these properties on system parameters. This Part I paper focuses on the signal and noise properties of cerebral blood volume (CBV) maps calculated using a nondeconvolution-based method. METHODS The CBV imaging chain was decomposed into a cascade of sub-imaging stages, which facilitated the derivation of analytical models for the probability density function, mean value, and noise variance of CBV. These models directly take CTP source image acquisition, reconstruction, and postprocessing parameters as inputs. Both numerical simulations and in vivo canine experiments were performed to validate these models. RESULTS The noise variance of CBV is linearly related to the noise variance of source images and is strongly influenced by the noise variance of the baseline images. Uniformly partitioning the total radiation dose budget across all time frames was found to be sub-optimal, and an optimal dose partition method was derived to minimize CBV noise. Results of the numerical simulation and animal studies validated the derived statistical properties of CBV. CONCLUSIONS The statistical properties of CBV imaging systems can be accurately modeled by extending the linear CT systems theory. Based on the statistical model, several key signal and noise characteristics of CBV were identified and an optimal dose partition method was developed to improve the image quality of CBV. This article is protected by copyright. All rights reserved.

[1]  H. Diener,et al.  Stent-retriever thrombectomy after intravenous t-PA vs. t-PA alone in stroke. , 2015, The New England journal of medicine.

[2]  M Cohnen,et al.  Radiation exposure of patients in comprehensive computed tomography of the head in acute stroke. , 2006, AJNR. American journal of neuroradiology.

[3]  A. Rai,et al.  Pre-intervention cerebral blood volume predicts outcomes in patients undergoing endovascular therapy for acute ischemic stroke , 2012, Journal of NeuroInterventional Surgery.

[4]  R. Gonzalez,et al.  Low signal, high noise and large uncertainty make CT perfusion unsuitable for acute ischemic stroke patient selection for endovascular therapy , 2012, Journal of NeuroInterventional Surgery.

[5]  D. Calvet,et al.  An update on brain imaging in transient ischemic attack. , 2015, Journal of neuroradiology. Journal de neuroradiologie.

[6]  R. Gonzalez,et al.  The Massachusetts General Hospital acute stroke imaging algorithm: an experience and evidence based approach , 2013, Journal of NeuroInterventional Surgery.

[7]  M Wintermark,et al.  FDA Investigates the Safety of Brain Perfusion CT , 2010, American Journal of Neuroradiology.

[8]  S. Prabhakaran,et al.  Perfusion computed tomography in transient ischemic attack. , 2011, Archives of neurology.

[9]  Zhengrong Liang,et al.  Iterative image reconstruction for cerebral perfusion CT using a pre-contrast scan induced edge-preserving prior , 2012, Physics in medicine and biology.

[10]  L. Axel Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis. , 1980, Radiology.

[11]  T-Y Lee,et al.  Theoretic Basis and Technical Implementations of CT Perfusion in Acute Ischemic Stroke, Part 1: Theoretic Basis , 2009, American Journal of Neuroradiology.

[12]  C. Derdeyn,et al.  Perfusion imaging in acute ischemic stroke: let us improve the science before changing clinical practice. , 2013, Radiology.

[13]  M. Wintermark,et al.  Does perfusion imaging add value compared with plain parenchymal and vascular imaging? , 2012, Journal of NeuroInterventional Surgery.

[14]  H. Kamal,et al.  Whole brain CT perfusion deficits using 320-detector-row CT scanner in TIA patients are associated with ABCD2 score , 2014, The International journal of neuroscience.

[15]  Carl E. Johnson,et al.  Using Quantitative CT Perfusion for Evaluation of Delayed Cerebral Ischemia Following Aneurysmal Subarachnoid Hemorrhage , 2011, American Journal of Neuroradiology.

[16]  T Redel,et al.  C-Arm CT Measurement of Cerebral Blood Volume: An Experimental Study in Canines , 2009, American Journal of Neuroradiology.

[17]  Hiroki Shirato,et al.  Differences in CT perfusion maps generated by different commercial software: quantitative analysis by using identical source data of acute stroke patients. , 2010, Radiology.

[18]  Kenya Murase,et al.  Effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies , 2005, Physics in medicine and biology.

[19]  D. Geng,et al.  Whole-Brain CT Perfusion and CT Angiography Assessment of Moyamoya Disease before and after Surgical Revascularization: Preliminary Study with 256-Slice CT , 2013, PloS one.

[20]  Guang-Hong Chen,et al.  Noise characteristics of CT perfusion imaging: how does noise propagate from source images to final perfusion maps? , 2016, SPIE Medical Imaging.

[21]  Rebecca Fahrig,et al.  Deconvolution-Based CT and MR Brain Perfusion Measurement: Theoretical Model Revisited and Practical Implementation Details , 2011, Int. J. Biomed. Imaging.

[22]  M. Lev Perfusion imaging of acute stroke: its role in current and future clinical practice. , 2013, Radiology.

[23]  William P. Dillon,et al.  Automated versus manual post-processing of perfusion-CT data in patients with acute cerebral ischemia: influence on interobserver variability , 2009, Neuroradiology.

[24]  K. Muir,et al.  Imaging of acute stroke and transient ischaemic attack , 2005, Journal of Neurology, Neurosurgery & Psychiatry.

[25]  Qiang Li,et al.  DIAGNOSTIC NEURORADIOLOGY , 2008 .

[26]  M. Wintermark,et al.  The role of imaging in acute ischemic stroke. , 2014, Neurosurgical focus.

[27]  Roland Bammer,et al.  Influence of Arterial Input Function on Hypoperfusion Volumes Measured With Perfusion-Weighted Imaging , 2003, Stroke.

[28]  T. Aoyama,et al.  Radiation dose evaluation in multidetector-row CT imaging for acute stroke with an anthropomorphic phantom. , 2010, The British journal of radiology.

[29]  M. P. Hayball,et al.  Colour perfusion imaging: a new application of computed tomography , 1991, The Lancet.

[30]  Hester F. Lingsma,et al.  A randomized trial of intraarterial treatment for acute ischemic stroke. , 2015, The New England journal of medicine.

[31]  Ivana Galinovic,et al.  Fully Automated Postprocessing Carries a Risk of Substantial Overestimation of Perfusion Deficits in Acute Stroke Magnetic Resonance Imaging , 2011, Cerebrovascular Diseases.

[32]  A. Dunning,et al.  CT Perfusion for Detection of Delayed Cerebral Ischemia in Aneurysmal Subarachnoid Hemorrhage: A Systematic Review and Meta-Analysis , 2014, American Journal of Neuroradiology.

[33]  Eric E. Smith,et al.  Randomized assessment of rapid endovascular treatment of ischemic stroke. , 2015, The New England journal of medicine.

[34]  A. Jain,et al.  Association of CT Perfusion Parameters with Hemorrhagic Transformation in Acute Ischemic Stroke , 2013, American Journal of Neuroradiology.

[35]  André Aichert,et al.  Denoising and artefact reduction in dynamic flat detector CT perfusion imaging using high speed acquisition: first experimental and clinical results , 2014, Physics in medicine and biology.

[36]  M. Wintermark,et al.  Cerebral perfusion‐CT patterns following seizure , 2010, European journal of neurology.

[37]  M. Manhart,et al.  C-Arm CT Measurement of Cerebral Blood Volume and Cerebral Blood Flow Using a Novel High-Speed Acquisition and a Single Intravenous Contrast Injection , 2013, American Journal of Neuroradiology.

[38]  W. Mali,et al.  Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction , 2014, European Radiology.

[39]  Andreas K. Maier,et al.  Dynamic Iterative Reconstruction for Interventional 4-D C-Arm CT Perfusion Imaging , 2013, IEEE Transactions on Medical Imaging.

[40]  Ting-Yim Lee,et al.  The effect of varying user-selected input parameters on quantitative values in CT perfusion maps. , 2004, Academic radiology.

[41]  A. Mushlin,et al.  Appropriate Use of CT Perfusion following Aneurysmal Subarachnoid Hemorrhage: A Bayesian Analysis Approach , 2014, American Journal of Neuroradiology.

[42]  M. Lev,et al.  Acute Stroke Imaging: What Is Sufficient for Triage to Endovascular Therapies? , 2012, American Journal of Neuroradiology.

[43]  M Wintermark,et al.  Cerebral perfusion CT: technique and clinical applications. , 2008, Journal of neuroradiology. Journal de neuroradiologie.

[44]  M. Krause,et al.  Endovascular therapy for ischemic stroke with perfusion-imaging selection. , 2015, The New England journal of medicine.

[45]  Michael H Lev,et al.  Arterial input function placement for accurate CT perfusion map construction in acute stroke. , 2010, AJR. American journal of roentgenology.