Electromagnetic compatibility analysis and design of ITER Poloidal Field converter unit

Due to the space limitation and safety concerns, the non-same-phase anti-parallel connection structure is applied in the ITER Poloidal Field (PF) converter unit. Consequently, the electromagnetic interference (EMI) has been one of the main concerns in its design. And this paper mainly presents the electromagnetic compatibility (EMC) analysis and design for ITER PF converter unit. At first, an isolated phase bus is designed for the shielding of the alternating magnetic field generated by the a.c. busbars. Its shielding effectiveness has been verified by the analysis and experimental test. Then, the stray magnetic field, which is generated by the converter bridges and very hard to be shielded, is analyzed and measured. And the results will provide useful inputs for the EMC design and test of the instrument and control (I&C) system. At last, a large coil pair, able to generate a uniform static magnetic field with high strength, is designed to evaluate the effects on electronic devices and to demonstrate the reliable and safe operation of the converters under strong stray magnetic field.

[1]  P. L. Mondino,et al.  AC/DC converters for the ITER Poloidal Field system , 1995, Proceedings of 16th International Symposium on Fusion Engineering.

[2]  I. Benfatto,et al.  ITER Coil Power Supply and Distribution System , 2011, 2011 IEEE/NPSS 24th Symposium on Fusion Engineering.

[3]  H. B. Dwight Some Proximity Effect Formulas for Bus Enclosures , 1964 .

[4]  C. Neumeyer,et al.  Review and analysis of the AC/DC converter of ITER coil power supply , 2010, 2010 Twenty-Fifth Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[5]  Soo-Hyun Baek,et al.  Analysis on the magnetic properties of an isolated phase bus system , 2001, ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501).

[6]  S.L. Ho,et al.  Calculations of Electromagnetic Field and Thermal Problem in an Isolated Phase Bus by Using FE Model , 2008, 2008 Joint International Conference on Power System Technology and IEEE Power India Conference.

[7]  N. Mitchell,et al.  Electrical Design Requirements on the ITER Coils , 2008, IEEE Transactions on Applied Superconductivity.

[8]  Guo Bin,et al.  Current Sharing Analysis of Arm Prototype for ITER PF Converter Bridge , 2014 .

[9]  W. F. Skeats,et al.  Minimizing the Magnetic Field Surrounding Isolated-Phase Bus by Electrically Continuous Enclosures , 1962, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[10]  王敏,et al.  Current Sharing Analysis of Arm Prototype for ITER PF Converter Bridge , 2014 .

[11]  M. Wang,et al.  Preliminary Design of the Poloidal Field AC/DC Converter System for the ITER Coil Power Supply , 2013 .

[12]  D. Cheng Field and wave electromagnetics , 1983 .

[13]  Arthur B. Niemoller,et al.  Isolated-Phase Bus Enclosure Currents , 1968 .