Experimental investigations of low-temperature driven ejection refrigeration cycle operating with isobutane

Abstract The rapid growth of various applications of the ejection refrigeration systems could be observed recently. Because of possibility of the application of solar or waste energy to supply the motive energy they can be thought as a real alternative to compression devices in air-conditioning technologies. Ejection system can effectively compete with absorption system under temperature of the motive heat source lower than 80 °C. The paper deals with experimental investigations carried out on a specially constructed prototype/stand for the case of isobutane as a working fluid under motive vapour temperature below 75 °C. The effects of operation parameters are analysed in the paper. The performance of the ejector is presented and discussed. Exemplary pressure distributions for on-design and off-design conditions are presented.

[1]  V. Dvorak Shape Optimization of Axisymmetric Ejector , 2006 .

[2]  Jianlin Yu,et al.  Applying mechanical subcooling to ejector refrigeration cycle for improving the coefficient of performance , 2007 .

[3]  C.j Korres,et al.  Solar cooling by thermal compression: The dependence of the jet thermal compressor efficiency on the compression ratio , 2002 .

[4]  Yau-Ming Chen,et al.  Experimental study of the performance characteristics of a steam-ejector refrigeration system , 1997 .

[5]  Yiping Dai,et al.  Exergy analysis, parametric analysis and optimization for a novel combined power and ejector refrigeration cycle , 2009 .

[6]  Masud Behnia,et al.  Investigation and improvement of ejector refrigeration system using computational fluid dynamics technique , 2007 .

[7]  M. McLinden,et al.  NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, Version 8.0 , 2007 .

[8]  Ian W. Eames,et al.  Results of an experimental study of an advanced jet-pump refrigerator operating with R245fa , 2007 .

[9]  Bin-Juine Huang,et al.  A solar ejector cooling system using refrigerant R141b , 1998 .

[10]  Aly Karameldin,et al.  Modelling and simulation of steam jet ejectors , 1999 .

[11]  Bin-Juine Huang,et al.  Empirical correlation for ejector design , 1999 .

[12]  Jianlin Yu,et al.  A theoretical study of a novel regenerative ejector refrigeration cycle , 2007 .

[13]  Nehad Al-Khalidy,et al.  An experimental study of an ejector cycle refrigeration machine operating on R113 , 1998 .

[14]  Bogdan Diaconu,et al.  Influence of geometrical factors on steam ejector performance – A numerical assessment , 2009 .

[15]  Randheer L. Yadav,et al.  Design aspects of ejectors: Effects of suction chamber geometry , 2008 .

[16]  Per Lundqvist,et al.  Natural working fluids for a solar-driven ejector refrigeration system , 2003 .

[17]  A. Mani,et al.  Experimental investigations on ejector refrigeration system with ammonia , 2007 .

[18]  T. Sriveerakul,et al.  Performance prediction of steam ejector using computational fluid dynamics: Part 2. Flow structure of a steam ejector influenced by operating pressures and geometries , 2007 .

[19]  Robert Dobson,et al.  Steam jet ejector cooling powered by waste or solar heat , 2009 .

[20]  Jean-Marie Seynhaeve,et al.  CFD analysis of a supersonic air ejector. Part II: Relation between global operation and local flow features , 2009 .

[21]  Saffa Riffat,et al.  CFD modelling and experimental investigation of an ejector refrigeration system using methanol as the working fluid , 2001 .

[22]  Andrew Ooi,et al.  CFD analysis of ejector in a combined ejector cooling system , 2005 .

[23]  Cai Wenjian,et al.  Area ratio effects to the performance of air-cooled ejector refrigeration cycle with R134a refrigerant , 2012 .

[24]  Da-Wen Sun,et al.  Comparative study of the performance of an ejector refrigeration cycle operating with various refrigerants , 1999 .

[25]  A. Selvaraju,et al.  Analysis of an ejector with environment friendly refrigerants , 2004 .

[26]  Jianlin Yu,et al.  A new ejector refrigeration system with an additional jet pump , 2006 .

[27]  Yann Bartosiewicz,et al.  Numerical and Experimental Investigations on Supersonic Ejectors , 2005 .

[28]  G. K. Alexis,et al.  A solar ejector cooling system using refrigerant R134a in the Athens area , 2005 .

[29]  T. Sriveerakul,et al.  Performance prediction of steam ejector using computational fluid dynamics: Part 1. Validation of the CFD results , 2007 .

[30]  M. Sokolov,et al.  Revisiting solar-powered ejector air conditioner––the greener the better , 2004 .

[31]  Per Lundqvist,et al.  A year-round dynamic simulation of a solar-driven ejector refrigeration system with iso-butane as a refrigerant , 2007 .

[32]  Da-Wen Sun,et al.  Variable geometry ejectors and their applications in ejector refrigeration systems , 1996 .

[33]  A. Khalil,et al.  Ejector design and theoretical study of R134a ejector refrigeration cycle , 2011 .

[34]  Muammer Ozgoren,et al.  Performance of a solar ejector cooling-system in the southern region of Turkey , 2007 .

[35]  Satha Aphornratana,et al.  An experimental investigation of a steam ejector refrigerator: the analysis of the pressure profile along the ejector , 2004 .

[36]  G. K. Alexis,et al.  Performance characteristics of a methanol ejector refrigeration unit , 2004 .

[37]  Jean-Marie Seynhaeve,et al.  CFD analysis of a supersonic air ejector. Part I: Experimental validation of single-phase and two-phase operation , 2009 .

[38]  Da-Wen Sun,et al.  Solar powered combined ejector-vapour compression cycle for air conditioning and refrigeration , 1997 .

[39]  Changyun Wen,et al.  Numerical investigation of geometry parameters for design of high performance ejectors , 2009 .

[40]  Satha Aphornratana,et al.  A small capacity steam-ejector refrigerator: experimental investigation of a system using ejector with movable primary nozzle , 1997 .

[41]  Rafet Yapici,et al.  Experimental investigation of performance of vapor ejector refrigeration system using refrigerant R123 , 2008 .

[42]  G. K. Alexis,et al.  A verification study of steam-ejector refrigeration model , 2003 .

[43]  Hyomin Jeong,et al.  CFD Analysis on the Influence of Converging Duct Angle on the Steam Ejector Performance , 2008 .

[44]  Yann Bartosiewicz,et al.  Numerical assessment of ejector operation for refrigeration applications based on CFD , 2006 .

[45]  M Ouzzane,et al.  Model development and numerical procedure for detailed ejector analysis and design , 2003 .

[46]  Clemens Pollerberg,et al.  Solar driven steam jet ejector chiller , 2009 .

[47]  Yuan-Jen Chang,et al.  Enhancement of a steam-jet refrigerator using a novel application of the petal nozzle , 2000 .

[48]  E. D. Rogdakis,et al.  Design and parametric investigation of an ejector in an air-conditioning system , 2000 .

[49]  Vaclav Dvorak,et al.  Supersonic flow structure in the entrance part of a mixing chamber of 2D model ejector , 2003 .