Research on self-excited initiation of a Medium-voltage DC (MVDC) multiphase synchronous generator-rectifier system

This paper has described the excitation system of a Medium-voltage DC (MVDC) multiphase synchronous generator-rectifier system and calculated the minimum frequency of the pilot-exciter needed for self-excited initiation. On this basis, a double closed-loop V/F control method is proposed according to the classical PI control algorithm for self-excited initiation. With the method, a prototype is constructed for test. The results show that both the self-excitation initiating and the speed-rising processes of the generator set have changed synchronously thus to reduce the time needed for MVDC multiphase synchronous generator-rectifier system to start and finish establishing the nominal DC voltage.

[1]  D. Bosich,et al.  MVDC power system voltage control through feedback linearization technique: Application to different shipboard power conversion architectures , 2013, 2013 IEEE Electric Ship Technologies Symposium (ESTS).

[2]  A. Tessarolo,et al.  Electric generation technologies for all-electric ships with Medium-Voltage DC power distribution systems , 2013, 2013 IEEE Electric Ship Technologies Symposium (ESTS).

[3]  Pranesh Rao,et al.  Coordination of digital excitation system settings for reliable operation , 2009, 2009 IEEE Power & Energy Society General Meeting.

[4]  Dezhi Liu,et al.  Experimental and Simulation Research on the Low-Frequency Oscillation of a 4-wire 12-Phase Generator-Rectifier-load system , 2010, 2010 Asia-Pacific Power and Energy Engineering Conference.

[5]  Alberto Tessarolo Experimental performance assessent of multiphase alternators supplying multiple AC/DC power converters , 2010 .

[6]  Chung-Yuen Won,et al.  Output voltage control of synchronous generator for ships using a PMG type digital AVR , 2009, 2009 IEEE Energy Conversion Congress and Exposition.

[7]  Ma WeiMing,et al.  A survey of the second-generation vessel integrated power system , 2011, 2011 International Conference on Advanced Power System Automation and Protection.

[8]  Zhen Zhong Su,et al.  Stability Boundary of Current Closed-Loop Control of Two-Quadrant H-Half Bridge Converter in SGBES , 2013 .

[9]  Dong Wang,et al.  A high speed induction generator based on power integration techniques , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..

[10]  Zhen Zhong Su,et al.  Linear Boundary of Current Closed-Loop Control of Two-Quadrant H-Half Bridge Converter in Excitation System , 2013 .

[11]  D. Boroyevich,et al.  Model-Based Digital Generator Control Unit for a Variable Frequency Synchronous Generator With Brushless Exciter , 2008, IEEE Transactions on Energy Conversion.

[12]  Dan Li,et al.  Voltage regulation in medium voltage DC systems , 2013, 2013 IEEE Electric Ship Technologies Symposium (ESTS).

[13]  S. Tnani,et al.  Direct control strategy of synchronous generators using DC/DC converter , 2012, IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society.